A particle filter motion prediction algorithm based on an autoregressive model for real-time MRI-guided radiotherapy of lung cancer

This work introduces a 2D motion prediction algorithm for lung tumors applied to dynamic MR images that combines intrafractional tumor deformations. It is developed in the context of MR-linac treatments and evaluates uniform and patient-specific margins about the gross tumor volume to optimize the tumor coverage. Seven early stage non-small cell lung cancer patients were imaged in treatment position with a 1.5 T magnetic resonance using a balanced steady-state free precession sequence for one minute at a rate of four images per second and were instructed to breathe normally. The particle filter, in combination with the autoregressive model, is used to sequentially track and predict the tumor position 250 ms in the future from the current image. In addition, the autocontour extracted from a previous study (Bourque et al 2016 Med. Phys. 43 5161–9) is projected to the predicted position and various margins are evaluated. Averaged over all patients, the root mean square errors are (1.3 ± 0.5) mm and (2.0 ± 0.8) mm with and without prediction, respectively, and the difference in centroid position is (1.1 ± 0.4) mm with the prediction. The addition of the prediction algorithm leads to inferior errors for all cases. With such predictor, enlarging the propagated contour by a uniform 2 mm margin leads to a minimum recall of 97% over the entire patient population. Considering patient-specific margins based on of the Gaussian distribution around the mean error, the margins vary from 0.8 to 3.0 mm in anterior–posterior direction and from 1.2 to 3.2 mm in the superior–inferior direction. This study concludes that the advantage of such prediction algorithm highly depends on the tumor motion characteristics. For both uniform and patient-specific margins evaluation, smaller treatment margins could be used when combined to an accurate tracking and motion prediction algorithm. These results could offer guidance for future MR-guided lung tumor treatments.

[1]  B. Fallone,et al.  The rotating biplanar linac-magnetic resonance imaging system. , 2014, Seminars in radiation oncology.

[2]  Bogdan J. Matuszewski,et al.  Choice of similarity measure, likelihood function and parameters for histogram based particle filter tracking in CCTV grey scale video , 2011, Image Vis. Comput..

[3]  Steffen Ringgaard,et al.  Three-dimensional liver motion tracking using real-time two-dimensional MRI. , 2014, Medical physics.

[4]  Gregory C Sharp,et al.  Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[5]  Satyapal Rathee,et al.  An artificial neural network (ANN)-based lung-tumor motion predictor for intrafractional MR tumor tracking. , 2012, Medical physics.

[6]  S P M Crijns,et al.  Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion , 2012, Physics in medicine and biology.

[7]  Jan J W Lagendijk,et al.  The magnetic resonance imaging-linac system. , 2014, Seminars in radiation oncology.

[8]  W. Schlegel,et al.  Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax , 2007, Physics in medicine and biology.

[9]  Steve B. Jiang,et al.  Gating based on internal/external signals with dynamic correlation updates , 2008, Physics in medicine and biology.

[10]  Marco Riboldi,et al.  Magnetic resonance imaging-guided versus surrogate-based motion tracking in liver radiation therapy: a prospective comparative study. , 2015, International journal of radiation oncology, biology, physics.

[11]  J G M Kok,et al.  Towards MRI-guided linear accelerator control: gating on an MRI accelerator , 2011, Physics in medicine and biology.

[12]  G Baroni,et al.  Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI , 2016, Physics in medicine and biology.

[13]  J. McClelland,et al.  MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning , 2006, Physics in medicine and biology.

[14]  Paul Keall,et al.  Audiovisual Biofeedback Improves Cine-Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency. , 2016, International journal of radiation oncology, biology, physics.

[15]  Sasa Mutic,et al.  The ViewRay system: magnetic resonance-guided and controlled radiotherapy. , 2014, Seminars in radiation oncology.

[16]  Albert Koong,et al.  Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. , 2009, Journal of vascular and interventional radiology : JVIR.

[17]  Andrew Jackson,et al.  High-tech will improve radiotherapy of NSCLC: a hypothesis waiting to be validated. , 2004, International journal of radiation oncology, biology, physics.

[18]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[19]  Satyapal Rathee,et al.  First demonstration of intrafractional tumor-tracked irradiation using 2D phantom MR images on a prototype linac-MR. , 2013, Medical physics.

[20]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[21]  David J. Hawkes,et al.  Respiratory motion models: a review. , 2013 .

[22]  T. V. D. Hagen,et al.  Why Yule-Walker should not be used for autoregressive modelling , 1996 .

[23]  Leonidas J. Guibas,et al.  The Earth Mover's Distance as a Metric for Image Retrieval , 2000, International Journal of Computer Vision.

[24]  Jan J W Lagendijk,et al.  Navigators for motion detection during real-time MRI-guided radiotherapy , 2012, Physics in medicine and biology.

[25]  M. Hoogeman,et al.  Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. , 2009, International journal of radiation oncology, biology, physics.

[26]  Erik Tryggestad,et al.  4D tumor centroid tracking using orthogonal 2D dynamic MRI: implications for radiotherapy planning. , 2013, Medical physics.

[27]  Jan-Jakob Sonke,et al.  Variability of four-dimensional computed tomography patient models. , 2008, International journal of radiation oncology, biology, physics.

[28]  Alexandra E Bourque,et al.  A particle filter based autocontouring algorithm for lung tumor tracking using dynamic magnetic resonance imaging. , 2016, Medical physics.

[29]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[30]  Paul J Keall,et al.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator. , 2014, Medical physics.

[31]  B Denis de Senneville,et al.  An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs , 2015, Physics in medicine and biology.

[32]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[33]  Rasmus Larsen,et al.  Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes , 2013, Physics in medicine and biology.

[34]  Stuart Crozier,et al.  The Australian magnetic resonance imaging-linac program. , 2014, Seminars in radiation oncology.

[35]  Paul J Keall,et al.  An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients , 2008, Physics in medicine and biology.