Engineering an in vitro model of a functional ligament from bone to bone.

For musculoskeletal tissues that transmit loads during movement, the interfaces between tissues are essential to minimizing injury. Therefore, the reproduction of functional interfaces within engineered musculoskeletal tissues is critical to the successful transfer of the technology to the clinic. The goal of this work was to rapidly engineer ligament equivalents in vitro that contained both the soft tissue sinew and a hard tissue bone mimetic. This goal was achieved using cast brushite (CaHPO(4)·2H(2)O) anchors to mimic bone and a fibrin gel embedded with fibroblasts to create the sinew. The constructs formed within 7 days. Fourteen days after seeding, the interface between the brushite and sinew could withstand a stress of 9.51 ± 1.7  kPa before failure and the sinew reached a Young's modulus value of 0.16 ± 0.03  MPa. Treatment with ascorbic acid and proline increased the collagen content of the sinew (from 1.34% ± 0.2% to 8.34% ± 0.37%), strength of the interface (29.24 ± 6  kPa), and modulus of the sinew (2.69 ± 0.25  MPa). Adding transforming growth factor-β resulted in a further increase in collagen (11.25% ± 0.39%), interface strength (42 ± 8  kPa), and sinew modulus (5.46 ± 0.68  MPa). Both scanning electron and Raman microscopy suggested that the interface between the brushite and sinew mimics the in vivo tidemark at the enthesis. This work describes a major step toward the development of tissue-engineered ligaments for the repair of ligament ruptures in humans.

[1]  Gordon W Blunn,et al.  Tendon bone healing can be enhanced by demineralized bone matrix: a functional and histological study. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[2]  S. Komarova,et al.  The use of RANKL-coated brushite cement to stimulate bone remodelling. , 2008, Biomaterials.

[3]  J. Ralphs,et al.  Fibrocartilage in tendons and ligaments — an adaptation to compressive load , 1998, Journal of anatomy.

[4]  K. Gross,et al.  The contribution of coating microstructure to degradation and particle release in hydroxyapatite coated prostheses. , 2002, Journal of biomedical materials research.

[5]  Jennifer Z. Paxton,et al.  Factors Affecting the Longevity and Strength in an In Vitro Model of the Bone–Ligament Interface , 2010, Annals of Biomedical Engineering.

[6]  J. F. Woessner,et al.  The determination of hydroxyproline in tissue and protein samples containing small proportions of this imino acid. , 1961, Archives of biochemistry and biophysics.

[7]  D. Mastrokalos,et al.  Donor Site Morbidity and Return to the Preinjury Activity Level after Anterior Cruciate Ligament Reconstruction Using Ipsilateral and Contralateral Patellar Tendon Autograft , 2005, The American journal of sports medicine.

[8]  L. Grover,et al.  In vitro biodegradation of three brushite calcium phosphate cements by a macrophage cell-line. , 2006, Biomaterials.

[9]  Maryjane Tremayne,et al.  Biologically mediated resorption of brushite cement in vitro. , 2006, Biomaterials.

[10]  David Kovacevic,et al.  Augmentation of Tendon-to-Bone Healing with a Magnesium-Based Bone Adhesive , 2008, The American journal of sports medicine.

[11]  David L Kaplan,et al.  Tissue engineering of ligaments. , 2004, Annual review of biomedical engineering.

[12]  M. Kjaer,et al.  The initiation of embryonic-like collagen fibrillogenesis by adult human tendon fibroblasts when cultured under tension , 2010, Biomaterials.

[13]  A. Wallace,et al.  Tendons and ligaments are anatomically distinct but overlap in molecular and morphological features—a comparative study in an ovine model , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  Robert P Keatch,et al.  Engineering the bone-ligament interface using polyethylene glycol diacrylate incorporated with hydroxyapatite. , 2009, Tissue engineering. Part A.

[15]  R. Zernicke,et al.  Structure, function and adaptation of bone-tendon and bone-ligament complexes. , 2005, Journal of musculoskeletal & neuronal interactions.

[16]  J. Ralphs,et al.  Where tendons and ligaments meet bone: attachment sites (‘entheses’) in relation to exercise and/or mechanical load , 2006, Journal of anatomy.

[17]  J. Ralphs,et al.  The skeletal attachment of tendons--tendon "entheses". , 2002, Comparative biochemistry and physiology. Part A, Molecular & integrative physiology.

[18]  Tendon-bone insertion repair and regeneration using polyglycolic acid sheet in the rabbit rotator cuff injury model , 2008 .

[19]  S. H. Richardson,et al.  Tension is required for fibripositor formation. , 2008, Matrix biology : journal of the International Society for Matrix Biology.

[20]  Andrés J. García,et al.  Engineering graded tissue interfaces , 2008, Proceedings of the National Academy of Sciences.

[21]  A. Banes,et al.  A new vacuum-operated stress-providing instrument that applies static or variable duration cyclic tension or compression to cells in vitro. , 1985, Journal of cell science.

[22]  Stephen B Doty,et al.  Development of controlled matrix heterogeneity on a triphasic scaffold for orthopedic interface tissue engineering. , 2006, Tissue engineering.

[23]  A. K. Aune,et al.  Four-Strand Hamstring Tendon Autograft Compared with Patellar Tendon-Bone Autograft for Anterior Cruciate Ligament Reconstruction , 2001, The American journal of sports medicine.

[24]  Eugene Boland,et al.  Development of self-assembled, tissue-engineered ligament from bone marrow stromal cells. , 2007, Tissue engineering.

[25]  謙 佐々木 Enhancement of tendon-bone osteointegration of anterior cruciate ligament graft using granulocyte colony-stimulating factor , 2009 .

[26]  C. Ju,et al.  Augmentation of tendon-bone healing by the use of calcium-phosphate cement. , 2004, The Journal of bone and joint surgery. British volume.

[27]  W. Nebelung,et al.  Histological findings of tendon-bone healing following anterior cruciate ligament reconstruction with hamstring grafts , 2003, Archives of Orthopaedic and Trauma Surgery.

[28]  Stephen B Doty,et al.  In vivo evaluation of a multiphased scaffold designed for orthopaedic interface tissue engineering and soft tissue-to-bone integration. , 2008, Journal of biomedical materials research. Part A.

[29]  H. Herø,et al.  Bonding capacity in bone of HIP-processed HA-coated titanium: mechanical and histological investigations. , 1995, Journal of biomedical materials research.

[30]  M. Oddy,et al.  Tendon re-attachment to metal prostheses in an in vivo animal model using demineralised bone matrix. , 2009, The Journal of bone and joint surgery. British volume.

[31]  Robert G. Dennis,et al.  Mesenchymal Cell Culture , 2002 .

[32]  Hiromitsu Toyoda,et al.  Generation of tendon‐to‐bone interface “enthesis” with use of recombinant BMP‐2 in a rabbit model , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[33]  Karl Grosh,et al.  Engineering of functional tendon. , 2004, Tissue engineering.

[34]  Braden C. Fleming,et al.  Anterior Cruciate Ligament Replacement: Comparison of Bone-Patellar Tendon-Bone Grafts with Two-Strand Hamstring Grafts A Prospective, Randomized Study , 2002, The Journal of bone and joint surgery. American volume.

[35]  Simon M Gianotti,et al.  Incidence of anterior cruciate ligament injury and other knee ligament injuries: a national population-based study. , 2009, Journal of science and medicine in sport.

[36]  Keith Baar,et al.  Regional variation of tibialis anterior tendon mechanics is lost following denervation. , 2006, Journal of applied physiology.

[37]  D. Caborn,et al.  Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[38]  Albert J Banes,et al.  Novel system for engineering bioartificial tendons and application of mechanical load. , 2003, Tissue engineering.

[39]  S L Woo,et al.  Measurement of mechanical properties of ligament substance from a bone‐ligament‐bone preparation , 1983, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[40]  M. Raspanti,et al.  Collagen fibril structure is affected by collagen concentration and decorin. , 2007, Biomacromolecules.

[41]  Ellen M Arruda,et al.  Structure and functional evaluation of tendon-skeletal muscle constructs engineered in vitro. , 2006, Tissue engineering.

[42]  F. Harrell,et al.  Anterior Cruciate Ligament Reconstruction Autograft Choice: Bone-Tendon-Bone versus Hamstring , 2004, The American journal of sports medicine.

[43]  Renato V. Iozzo,et al.  Targeted Disruption of Decorin Leads to Abnormal Collagen Fibril Morphology and Skin Fragility , 1997, Journal of Cell Biology.

[44]  D. B. O’Neill,et al.  Arthroscopically Assisted Reconstruction of the Anterior Cruciate Ligament. A Prospective Randomized Analysis of Three Techniques* , 1996, The Journal of bone and joint surgery. American volume.

[45]  J. Ralphs,et al.  Entheses--the bony attachments of tendons and ligaments. , 2001, Italian journal of anatomy and embryology = Archivio italiano di anatomia ed embriologia.