Amperometric detection of cholesterol using cobalt (II) chloride as an electrocatalyst in aprotic media

Abstract The determination of cholesterol concentration in the blood is an important characteristic of the state of health. Modern methods for the detection of cholesterol involve the use of enzymes or expensive and complicated equipment. In this study, an enzymeless electrochemical method for the quantitative determination of cholesterol using cobalt (II) chloride as an electrocatalyst has been proposed. An analytical signal was peak current of cobalt (II) chloride faradaic oxidation on a platinum disk electrode in acetonitrile media in the presence of cholesterol via linear sweep voltammetry. A possible path of the electrocatalytic oxidation of cholesterol on the electrode surface was proposed. The catalytic constant kcat and the Michaelis constant Km calculated for the electrocatalytic oxidation process of cholesterol on the electrode surface are comparable in magnitude to the natural enzyme cholesterol oxidase, indicating the high efficiency of CoCl2 as an electrocatalyst for oxidation and, therefore, the determination of cholesterol. The highest value and the best reproducibility of analytical signal are reached at a CoCl2 concentration of 25 mM and a scan rate of 100 mV·s− 1. The linear region of the calibration curve “current-cholesterol concentration” obtained using a developed method in a solution of 0.1 M LiClO4 and 25 mM CoCl2 in acetonitrile is 25–200 μM (R2 = 0.971) with a detection limit of 2 μM.

[1]  Chenglin Sun,et al.  Indirect electrochemical oxidation of pentachlorophenol in the presence of different halides: behavior and mechanism , 2014 .

[2]  M. Oliveira,et al.  Cholesterol determination in foods: Comparison between high performance and ultra-high performance liquid chromatography. , 2016, Food chemistry.

[3]  M. Rodrigo,et al.  Electrochemical advanced oxidation processes: today and tomorrow. A review , 2014, Environmental Science and Pollution Research.

[4]  Aicheng Chen,et al.  High-performance electrochemical biosensor for the detection of total cholesterol. , 2011, Biosensors & bioelectronics.

[5]  Bansi D. Malhotra,et al.  Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films , 2006 .

[6]  Hao Yu,et al.  Nonenzymatic sensing of glucose using a carbon ceramic electrode modified with a composite film made from copper oxide, overoxidized polypyrrole and multi-walled carbon nanotubes , 2014, Microchimica Acta.

[7]  L. Pollegioni,et al.  Kinetic mechanisms of cholesterol oxidase from Streptomyces hygroscopicus and Brevibacterium sterolicum. , 1999, European journal of biochemistry.

[8]  J. Morzycki,et al.  Electrochemical oxidation of cholesterol , 2015, Beilstein journal of organic chemistry.

[9]  Shen-ming Chen,et al.  Zinc Oxide/Zinc Hexacyanoferrate Hybrid Film-Modified Electrodes for Guanine Detection , 2007 .

[10]  H. H. Brown,et al.  Rapid procedure for determination of free serum cholesterol. , 1954 .

[11]  U. Ritter,et al.  Non-enzymatic analysis of cholesterol in acetonitrile solutions , 2014 .

[12]  C. Furlani,et al.  Formation equilibria of pseudotetrahedral Co(II) halogenocomplexes in acetonitrile , 1970 .

[13]  M. Kim,et al.  Colorimetric Quantification of Glucose and Cholesterol in Human Blood Using a Nanocomposite Entrapping Magnetic Nanoparticles and Oxidases. , 2015, Journal of nanoscience and nanotechnology.

[14]  A. Kozitsina,et al.  Catalytic systems based on the organic nickel(ii) complexes in chronoamperometric determination of urea and creatinine , 2009 .

[15]  Tae Geun Kim,et al.  Fluorescent cholesterol sensing using enzyme-modified CdSe/ZnS quantum dots , 2012, Journal of Nanoparticle Research.

[16]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[17]  Kunihisa Yoshida Electrooxidation in Organic Chemistry: The Role of Cation Radicals as Synthetic Intermediates , 1984 .

[18]  Zaiping Guo,et al.  Preparation and characterization of spinel Li4Ti5O12 nanoparticles anode materials for lithium ion battery , 2012, Journal of Nanoparticle Research.

[19]  A. Fakhari,et al.  Electrocatalytic oxidation and determination of insulin at nickel oxide nanoparticles-multiwalled carbon nanotube modified screen printed electrode. , 2013, Biosensors & bioelectronics.

[20]  Chunming Wang,et al.  Fabrication of the Cu2O/polyvinyl pyrrolidone-graphene modified glassy carbon-rotating disk electrode and its application for sensitive detection of herbicide paraquat , 2012 .

[21]  A. Kotani,et al.  Determination of total cholesterol in serum by high-performance liquid chromatography with electrochemical detection. , 2007, Journal of chromatography. A.

[22]  M. Enyo,et al.  Theory of concentration overpotential and applicability of the rotating disk electrode to the analysis of electrode kinetics , 1970 .

[23]  P. Solanki,et al.  Polypyrrole/multiwalled carbon nanotubes‐based biosensor for cholesterol estimation , 2012 .

[24]  G. Muralidharan,et al.  Polyvinylpyrrolidone stabilized palladium nanospheres as simple and novel electrochemical sensor for amperometric hydrogen peroxide detection , 2015 .

[25]  K. Ho,et al.  Amperometric detection of cholesterol using an indirect electrochemical oxidation method , 2011, Steroids.

[26]  B. Lu,et al.  Nonenzymatic glucose sensor based on nickel(II)oxide/ordered mesoporous carbon modified glassy carbon electrode. , 2013, Colloids and surfaces. B, Biointerfaces.

[27]  Chelladurai Karuppiah,et al.  An Ultrahigh Selective and Sensitive Enzyme-Free Hydrogen Peroxide Sensor Based on Palladium Nanoparticles and Nafion-Modified Electrode , 2014, Electrocatalysis.

[28]  Sandro Carrara,et al.  Cholesterol amperometric biosensor based on cytochrome P450scc. , 2004, Biosensors & bioelectronics.