Aortic valve procedures at the time of ventricular assist device placement.

[1]  Nir Uriel,et al.  Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[2]  S. Russell,et al.  Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[3]  K. Krishan,et al.  Successful use of continuous flow ventricular assist device in a patient with mechanical mitral and aortic valve prosthesis without replacement or exclusion of valves. , 2010, Interactive cardiovascular and thoracic surgery.

[4]  S. Russell,et al.  Advanced heart failure treated with continuous-flow left ventricular assist device. , 2009, The New England journal of medicine.

[5]  F. Pagani,et al.  Low Operative Mortality With Implantation of a Continuous-Flow Left Ventricular Assist Device and Impact of Concurrent Cardiac Procedures , 2009, Circulation.

[6]  Nader Moazami,et al.  Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. , 2009, Journal of the American College of Cardiology.

[7]  James O. Mudd,et al.  Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[8]  M. Borger,et al.  Early changes in bioprosthetic heart valves following ventricular assist device implantation. , 2007, International journal of cardiology.

[9]  M. Slaughter,et al.  Management of aortic insufficiency with continuous flow left ventricular assist devices: bioprosthetic valve replacement. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[10]  R. Dowling,et al.  Simple mechanical aortic valve closure in ventricular assist device recipients. , 2006, Annals of Thoracic Surgery.

[11]  O. Frazier,et al.  Acquired commissural fusion of aortic valves in patients with left ventricular assist devices. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[12]  M. Oz,et al.  LVAD support in patients with bioprosthetic valves. , 2002, The Annals of thoracic surgery.

[13]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[14]  J. Narula,et al.  Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: signs, symptoms, and concerns. , 2001, Journal of Thoracic and Cardiovascular Surgery.

[15]  M. Oz,et al.  Surgical management of valvular disease in patients requiring left ventricular assist device support. , 2001, The Annals of thoracic surgery.

[16]  L. Miller,et al.  Partial aortic valve fusion induced by left ventricular assist device. , 2000, The Annals of thoracic surgery.

[17]  D. Bull,et al.  Patch closure of the aortic anulus in a recipient of a ventricular assist device. , 2000, The Journal of thoracic and cardiovascular surgery.

[18]  M. Swartz,et al.  Ventricular assist device support in patients with mechanical heart valves. , 1999, The Annals of thoracic surgery.

[19]  J. Magovern,et al.  Aortic valve patch closure: an alternative to replacement with HeartMate LVAS insertion. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[20]  R L Kormos,et al.  Evaluation of Bioprosthetic Valve‐Associated Thrombus in Ventricular Assist Device Patients , 1993, Circulation.

[21]  H. Matsuda,et al.  Benefit of heparin infusion through left ventricular catheter in patient undergoing mechanical valve replacement with the aid of a left ventricular assist device. , 1991, Journal of Thoracic and Cardiovascular Surgery.

[22]  T. Mesana,et al.  Thromboembolytic complications during circulatory assistance with a centrifugal pump in patients with valvular prostheses. , 1990, ASAIO transactions.

[23]  Robert L Kormos,et al.  Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implants. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[24]  L. Miller,et al.  Management of aortic insufficiency in patients with left ventricular assist devices: a simple coaptation stitch method (Park's stitch). , 2004, The Journal of thoracic and cardiovascular surgery.