Interventional Cardiovascular Magnetic Resonance
暂无分享,去创建一个
[1] David Atkinson,et al. Real-Time Reconstruction of Sensitivity Encoded Radial Magnetic Resonance Imaging Using a Graphics Processing Unit , 2009, IEEE Transactions on Medical Imaging.
[2] Robert J. Lederman,et al. Cardiovascular Interventional MRI , 2005 .
[3] Reza Razavi,et al. In vivo evaluation and proof of radiofrequency safety of a novel diagnostic MR‐electrophysiology catheter , 2011, Magnetic resonance in medicine.
[4] R. Günther,et al. Magnetic Resonance–Guided Cardiac Interventions Using Magnetic Resonance–Compatible Devices: A Preclinical Study and First-in-Man Congenital Interventions , 2010, Circulation. Cardiovascular interventions.
[5] R. Lederman. Cardiovascular Interventional Magnetic Resonance Imaging , 2005, Circulation.
[6] Vivek Muthurangu,et al. Comparison of Bare Metal Stenting and Percutaneous Pulmonary Valve Implantation for Treatment of Right Ventricular Outflow Tract Obstruction: Use of an X-Ray/Magnetic Resonance Hybrid Laboratory for Acute Physiological Assessment , 2009, Circulation.
[7] Vivek Muthurangu,et al. Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow , 2004, Circulation.
[8] D. Hill,et al. Cardiac catheterisation guided by MRI in children and adults with congenital heart disease , 2003, The Lancet.
[9] Vivek Muthurangu,et al. Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization. , 2005, American journal of physiology. Heart and circulatory physiology.
[10] Vivek Muthurangu,et al. Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients , 2004, Magnetic resonance in medicine.
[11] Alastair Martin,et al. Magnetic Resonance–Guided Cardiac Catheterization in a Swine Model of Atrial Septal Defect , 2003, Circulation.
[12] M A Viergever,et al. MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. , 1997, Radiology.
[13] Reza Razavi,et al. Magnetic Resonance–Guided Cardiac Interventions Using Magnetic Resonance–Compatible DevicesClinical Perspective , 2010 .
[14] Kawal S. Rhode,et al. Registration and tracking to integrate X-ray and MR images in an XMR Facility , 2003, IEEE Transactions on Medical Imaging.
[15] E. Wellnhofer,et al. Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension , 2005, Heart.
[16] Titus Kuehne,et al. Magnetic Resonance Imaging Analysis of Right Ventricular Pressure-Volume Loops: In Vivo Validation and Clinical Application in Patients With Pulmonary Hypertension , 2004, Circulation.