Control scheme and networked control architecture for the Berkeley lower extremity exoskeleton (BLEEX)

The Berkeley lower extremity exoskeleton (BLEEX) is a load-carrying and energetically autonomous human exoskeleton that, in this first generation prototype, carries up to a 34 kg (75 Ib) payload for the pilot and allows the pilot to walk at up to 1.3 m/s (2.9 mph). This article focuses on the human-in-the-loop control scheme and the novel ring-based networked control architecture (ExoNET) that together enable BLEEX to support payload while safely moving in concert with the human pilot. The BLEEX sensitivity amplification control algorithm proposed here increases the closed loop system sensitivity to its wearer's forces and torques without any measurement from the wearer (such as force, position, or electromyogram signal). The tradeoffs between not having sensors to measure human variables, the need for dynamic model accuracy, and robustness to parameter uncertainty are described. ExoNET provides the physical network on which the BLEEX control algorithm runs. The ExoNET control network guarantees strict determinism, optimized data transfer for small data sizes, and flexibility in configuration. Its features and application on BLEEX are described

[1]  Homayoon Kazerooni,et al.  The human power amplifier technology at the University of California, Berkeley , 1996, Robotics Auton. Syst..

[2]  Adam Zoss,et al.  On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX) , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[3]  Z. Stojiljkovic,et al.  Development of active anthropomorphic exoskeletons , 2007, Medical and biological engineering.

[4]  Sunghoon Kim,et al.  HIGH SPEED RING-BASED DISTRIBUTED NETWORKED CONTROL SYSTEM FOR REAL-TIME MULTIVARIABLE APPLICATIONS , 2004 .

[5]  Yoshiyuki Sankai,et al.  Power Assist System HAL-3 for Gait Disorder Person , 2002, ICCHP.

[6]  Steve Biegacki,et al.  The application of DeviceNet in process control , 1996 .

[7]  Sunghoon Kim,et al.  High-speed communication network for controls with the application on the exoskeleton , 2004, Proceedings of the 2004 American Control Conference.

[8]  Jerry E. Pratt,et al.  The RoboKnee: an exoskeleton for enhancing strength and endurance during walking , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[9]  John D. Wheels Process control communications: Token bus, CSMA/CD, or token ring? , 1993 .

[10]  Jack M. Winters,et al.  Analysis of Fundamental Human Movement Patterns Through the Use of In-Depth Antagonistic Muscle Models , 1985, IEEE Transactions on Biomedical Engineering.

[11]  A. Ray,et al.  Introduction to networking for integrated control systems , 1989, IEEE Control Systems Magazine.

[12]  Gianluca Cena,et al.  On the performances of two popular fieldbuses , 1997, Proceedings 1997 IEEE International Workshop on Factory Communication Systems. WFCS'97.

[13]  Homayoon Kazerooni,et al.  System identification for the Berkeley lower extremity exoskeleton (BLEEX) , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[14]  Francis Lepage,et al.  Design of the distributed architecture of a machine-tool using FIP fieldbus , 1996, Proceedings of International Conference on Application Specific Systems, Architectures and Processors: ASAP '96.

[15]  Homayoon Kazerooni,et al.  Hybrid hydraulic-electric power unit for field and service robots , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[16]  Homayoon Kazerooni,et al.  The dynamics and control of a haptic interface device , 1994, IEEE Trans. Robotics Autom..

[17]  Adam Zoss,et al.  On the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX) , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[18]  Lihua Huang,et al.  On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX) , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[19]  D. Wilkie The relation between force and velocity in human muscle , 1949, The Journal of physiology.

[20]  James Moyne,et al.  Performance evaluation of control networks: Ethernet, ControlNet, and DeviceNet , 2001 .

[21]  Keijiro Yamamoto,et al.  Development of Power Assisting Suit for Assisting Nurse Labor , 2002 .