Experimental study of pulsatile and steady flow through a smooth tube and an atherosclerotic coronary artery casting of man.

In vitro investigation of pulsatile and steady flows through a smooth, straight circular tube and a diseased human coronary artery cast was conducted with sugar-water solutions simulating the viscosity of blood. Time averaged pressure drops for pulsatile flows measured in the circular tube over a Reynolds number ranging from 50 to 1,000 were found to be identical to those for steady flows in the same tube, both of which were in excellent agreement with the Poiseuille flow prediction. For the polyurethane case (# 124) made from a human main coronary with significant but 'non obstructive' diffuse atherosclerotic disease, pressure drops for steady flows were found to be greater than Poiseuille flow predictions by a factor of 3-8 in the physiological Reynolds number range from about 100 to 400. Pulsatile flows in the same artery cast resulted in additional 30% increases in time averaged pressure drops, and thus flow resistance, compared to the steady flow data. Steady and pulsatile flow data measured in a straight, axisymmetric model of cast # 124 showed considerably smaller increases in flow resistance than those observed in # 124 casting.

[1]  B. B. Roe,et al.  CORONARY BLOOD FLOW IN THE INTACT CONSCIOUS DOG: STUDIES WITH MINIATURE ELECTROMAGNETIC FLOW TRANSDUCERS. , 1963, The Journal of thoracic and cardiovascular surgery.

[2]  A. Bruschke,et al.  Clinical Course of Patients with Normal, and Slightly or Moderately Abnormal Coronary Arteriograms: A Follow‐up Study on 500 Patients , 1973, Circulation.

[3]  W. Likoff,et al.  Devolutionary pattern of coronary atherosclerosis in patients with angina pectoris. Coronary arteriographic studies. , 1974, The American journal of cardiology.

[4]  G. Ross,et al.  Simultaneous Electromagnetic Measurement of Blood Flow in the Major Coronary Arteries , 1964, Nature.

[5]  N R Cholvin,et al.  Pressure Drop across Artificially Induced Stenoses in the Femoral Arteries of Dogs , 1975, Circulation research.

[6]  C G ROB,et al.  Hemodynamic effects of arterial stenosis. , 1963, Surgery.

[7]  D. F. Young,et al.  Flow characteristics in models of arterial stenoses. I. Steady flow. , 1973, Journal of biomechanics.

[8]  The resolution of the ultrasound pulsed doppler for blood velocity measurements. , 1973, Journal of biomechanics.

[9]  C J Mills,et al.  A catheter tip electromagnetic velocity probe. , 1966, Physics in medicine and biology.

[10]  W R Brody,et al.  Theoretical analysis of the CW doppler ultrasonic flowmeter. , 1974, IEEE transactions on bio-medical engineering.

[11]  F. Dullien,et al.  Flow rate‐pressure gradient measurements in periodically nonuniform capillary tubes , 1973 .

[12]  E. S. Furgason,et al.  The Dependence of Ultrasound Doppler Bandwidth on Beam Geometry , 1980, IEEE Transactions on Sonics and Ultrasonics.

[13]  R. F. Rushmer,et al.  A Pulsed Ultrasonic Flowmeter , 1959 .

[14]  Shigeo Uchida,et al.  The pulsating viscous flow superposed on the steady laminar motion of incompressible fluid in a circular pipe , 1956 .

[15]  Roberts Wc The status of the coronary arteries in fatal ischemic heart disease. , 1975 .

[16]  E S Beckenbach,et al.  Computer densitometry for angiographic assessment of arterial cholesterol content and gross pathology in human atherosclerosis. , 1977, The Journal of laboratory and clinical medicine.

[17]  D. E. Gregg,et al.  Flow in the Major Branches of the Left Coronary Artery during Experimental Coronary Insufficiency in the Unanesthetized Dog , 1968, Circulation research.

[18]  S. E. Logan,et al.  On the Fluid Mechanics of Human Coronary Artery Stenosis , 1975, IEEE Transactions on Biomedical Engineering.

[19]  D. R. Gross,et al.  Pressure-diameter relationships in the coronary artery of intact, awake calves. , 1981, Journal of biomechanics.

[20]  Roberto Fumero,et al.  OPTIMISTISATION OF BLOOD PUMPING SYSTEMS , 1980 .

[21]  Theodor Sexl,et al.  Über den von E. G. Richardson entdeckten „Annulareffekt“ , 1930 .

[22]  C. Hartley,et al.  Resolution of Frequency Aliases in Ultrasonic Pulsed Doppler Velocimeters , 1981, IEEE Transactions on Sonics and Ultrasonics.

[23]  A. W. Nelson,et al.  Blood velocity patterns in coronary arteries. , 1977, Journal of Biomechanical Engineering.

[24]  R. Mates,et al.  Fluid Dynamics of Coronary Artery Stenosis , 1978, Circulation research.

[25]  D. F. Young,et al.  Effect of geometry on pressure losses across models of arterial stenoses. , 1976, Journal of biomechanics.

[26]  J. S. Cole,et al.  An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. , 1974, Journal of applied physiology.

[27]  P. Steele,et al.  Abnormal platelet survival time in men with myocardial infarction and normal coronary arteriogram. , 1978, The American journal of cardiology.

[28]  L. Kuller,et al.  Arteriosclerosis of Coronary Arteries in Sudden, Unexpected Deaths , 1975, Circulation.

[29]  G. Rincon,et al.  Natural history of severe proximal coronary artery disease as documented by coronary cineangiography. , 1974, The American journal of cardiology.

[30]  A. Huvos,et al.  Coronary Inflow and Oxygen Usage Following Cardiac Sympathetic Nerve Stimulation in Unanesthetized Dogs , 1965, Circulation research.

[31]  H F Stegall,et al.  New method to measure phasic coronary blood velocity in man. , 1971, American heart journal.

[32]  R. M. Nerem,et al.  An Experimental Study of the Fluid Dynamics of Multiple Noncritical Stenoses , 1977 .

[33]  G W Hamilton,et al.  Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. , 1974, The American journal of cardiology.

[34]  J. Mehta,et al.  Platelet function studies in coronary artery disease. V. Evidence for enhanced platelet microthrombus formation activity in acute myocardial infarction. , 1979, The American journal of cardiology.

[35]  H. Barnes,et al.  On pulsatile flow of non-Newtonian liquids , 1971 .

[36]  J. F. Herrick,et al.  The effect on the blood flow of decreasing the lumen of a blood vessel , 1938 .

[37]  D. Redwood,et al.  Uses and Limitations of Stress Testing in the Evaluation of Ischemic Heart Disease , 1972, Circulation.

[38]  Daniel Hershey,et al.  Friction factors and pressure drop for sinusoidal laminar flow of water and blood in rigid tubes , 1967 .

[39]  D. Blankenhorn,et al.  Regression of atherosclerosis. , 1979, Annual review of medicine.

[40]  J. Womersley Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known , 1955, The Journal of physiology.

[41]  On the flow of Newtonian and non-Newtonian liquids through corrugated pipes , 1971 .