Exergetic and environmental assessment of room air conditioners in Turkish market

This study utilizes two factors, EEF (exergy efficiency factor) or exergetic COP (coefficient of performance) and MTEWI (modified total equivalent warming impact), which was proposed to evaluate exergetic and environmental performance of RAC (room air conditioners) sold in the Turkish market. In the study, vapour compression cooling cycle used whole RAC units is taken as model for the analyses. The results are shown that average EEF value of units using R-22 and R-410A gas are 74.53% and 74.64% respectively. Besides, R-410A gas, which is used in many split systems and marketed as an environmental friendly gas, has an effect that is approximately 23.18% higher than the R-22 gas which is no more in use. The study finally emphasizes the reasons why EEF and MTEWI factors should be given priority in terms of efficiency and environmental effects in the RAC units.

[1]  Ibrahim Dincer,et al.  Thermodynamic performance assessment of wind energy systems: An application , 2011 .

[2]  J.M.N. van Kasteren,et al.  Exergy Analysis - A tool for sustainable technology - in engineering , 1998 .

[3]  Jie Ji,et al.  Energetic and exergetic investigation of an organic Rankine cycle at different heat source temperatures , 2012 .

[4]  Guobing Zhou,et al.  Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290 , 2010 .

[5]  A. Stegou-Sagia,et al.  Exergy losses in refrigerating systems. A study for performance comparisons in compressor and condenser , 2003 .

[6]  Gerry Carrington,et al.  Exergy analysis of an isothermal heat pump dryer , 2011 .

[7]  W. Chen,et al.  A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners , 2008 .

[8]  Y. Çengel,et al.  Thermodynamics : An Engineering Approach , 1989 .

[9]  Abel Hernandez-Guerrero,et al.  Entropy generation as an environmental impact indicator and a sample application to freshwater ecosystems eutrophication , 2013 .

[10]  A. M. Blanco-Marigorta,et al.  Exergetic comparison of two different cooling technologies for the power cycle of a thermal power pl , 2011 .

[11]  Jiang Lin,et al.  Stay cool with less work : China's new energy-efficiency standards for air conditioners , 2008 .

[12]  M. Ziya Söğüt A research on exergy consumption and potential of total CO2 emission in the Turkish cement sector , 2012 .

[13]  Selçuk Bilgen,et al.  Thermodynamic Aspects of Renewable and Sustainable Development , 2009 .

[14]  Horst Kruse,et al.  Refrigerant use in Europe , 2000 .

[15]  Gadhiraju Venkatarathnam The coefficient of performance of an ideal air conditioner , 2009 .

[16]  Ali Behbahaninia,et al.  Thermoeconomic optimization and exergy analysis of CO 2/NH 3 cascade refrigeration systems , 2011 .

[17]  Derya Burcu Özkan,et al.  Exergy analysis of a solar assisted absorption cooling system on an hourly basis in villa applicatio , 2010 .

[18]  Ibrahim Dincer,et al.  Exergy-cost-energy-mass analysis of thermal systems and processes , 2003 .

[19]  Ibrahim Dincer,et al.  Thermodynamic aspects of renewables and sustainable development , 2005 .

[20]  Philippe Goffin,et al.  Low exergy building systems implementation , 2012 .

[21]  Arif Hepbasli,et al.  A key review on exergetic analysis and assessment of renewable energy resources for a sustainable future , 2008 .

[22]  E. Torrella,et al.  A general methodology for energy comparison of intermediate configurations in two-stage vapour compr , 2011 .

[23]  Ibrahim Dincer,et al.  A comparative study on energetic, exergetic and environmental performance assessments of novel M-Cycle based air coolers for buildings , 2012 .

[24]  Arif Hepbasli,et al.  A comparative study on exergetic assessment of two ground-source (geothermal) heat pump systems for residential applications , 2007 .