Thread shape factor: evaluation of three different orthodontic miniscrews stability.
暂无分享,去创建一个
Marco Migliorati | A Silvestrini Biavati | S. Benedicenti | F. Barberis | A. Signori | M. Migliorati | S. Drago | S Benedicenti | A Signori | S Drago | P Cirillo | F Barberis | P. Cirillo | A. Silvestrini Biavati
[1] A. Signori,et al. Temporary anchorage device stability: an evaluation of thread shape factor. , 2012, European journal of orthodontics.
[2] Kenneth A Johnson,et al. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. , 2005, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[3] B. Melsen. Mini-implants: Where are we? , 2005, Journal of clinical orthodontics : JCO.
[4] B Melsen,et al. Miniscrews as orthodontic anchorage: a preliminary report. , 1998, The International journal of adult orthodontics and orthognathic surgery.
[5] D J Downey,et al. Optimizing Bone Screw Pullout Force , 1990, Journal of orthopaedic trauma.
[6] B Melsen,et al. Immediate loading of implants used for orthodontic anchorage. , 2000, Clinical orthodontics and research.
[7] Zhihe Zhao,et al. Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic analysis. , 2010, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[8] C. Goracci,et al. Soft bone primary stability of 3 different miniscrews for orthodontic anchorage: a resonance frequency investigation. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[9] P. Dechow,et al. Effects of miniscrew orientation on implant stability and resistance to failure. , 2010, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[10] Jae-Hyun Sung,et al. Development of orthodontic micro-implants for intraoral anchorage. , 2003, Journal of clinical orthodontics : JCO.
[11] Tohru Yoshida,et al. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. , 2007, The International journal of oral & maxillofacial implants.
[12] H. Hwang,et al. Bone density measurement in interdental areas with simulated placement of orthodontic miniscrew implants. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[13] S. Marshall,et al. Effect of screw diameter on orthodontic skeletal anchorage. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[14] S. Tecco,et al. Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics. , 2011, Orthodontics & craniofacial research.
[15] Shouichi Miyawaki,et al. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. , 2003, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[16] R. Behrents,et al. Pitch and longitudinal fluting effects on the primary stability of miniscrew implants. , 2009, The Angle orthodontist.
[17] B. Melsen,et al. Miniscrew Implants: The Aarhus Anchorage System , 2005 .
[18] E. Suzuki,et al. Placement and removal torque values of orthodontic miniscrew implants. , 2011, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[19] Mitsuru Motoyoshi,et al. Recommended placement torque when tightening an orthodontic mini-implant. , 2006, Clinical oral implants research.
[20] R M Harrington,et al. Factors affecting the pullout strength of cancellous bone screws. , 1996, Journal of biomechanical engineering.
[21] C. Evans,et al. Predictors of initial stability of orthodontic miniscrew implants. , 2011, European journal of orthodontics.
[22] R. Behrents,et al. Stability of immediately loaded 3- and 6-mm miniscrew implants in beagle dogs--a pilot study. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.