Out-of-plane behaviour of a full scale stone masonry façade. Part 1: specimen and ground motion selection

SUMMARY The out-of-plane response of walls in existing stone masonry buildings is one of the major causes of vulnerability commonly observed in post-earthquake damage surveys. In this context, a shaking table (ST) test campaign was carried out on a full-scale masonry facade mainly focusing on the characterization of its out-of-plane overturning behaviour. The structure tested on the ST is a partial reproduction of an existing building from Azores, damaged during the 9 July 1998 Faial earthquake. The definition of the tested specimen as well as the selection of the input ground motion is reported in this paper. A specific emphasis is given to the definition of the time-history to be applied during the tests because it was felt as an essential and crucial part of the work to obtain the desired overturning behaviour. The accelerogram to be imposed was selected from a large set of accelerograms (74) by means of a step-by-step procedure on the basis of several numerical analyses resorting to the rocking response of rigid blocks. A companion paper (Part 2) focuses on the ST test results and detailed data interpretation. Copyright © 2013 John Wiley & Sons, Ltd.

[1]  G. Housner The behavior of inverted pendulum structures during earthquakes , 1963 .

[2]  Polona Weiss,et al.  Seismic Upgrading of Old Brick-Masonry Urban Houses: Tying of Walls with Steel Ties , 1996 .

[3]  Mohammad Aslam,et al.  Earthquake Rocking Response of Rigid Bodies , 1980 .

[4]  Gianmarco De Felice,et al.  Out‐of‐plane seismic behaviour of rocking masonry walls , 2012 .

[5]  António Arêde,et al.  In situ cyclic tests on existing stone masonry walls and strengthening solutions , 2011 .

[6]  Najif Ismail,et al.  PERFORMANCE OF UNREINFORCED AND RETROFITTED MASONRY BUILDINGS DURING THE 2010 DARFIELD EARTHQUAKE , 2010 .

[7]  Dina D'Ayala,et al.  Definition of Collapse Mechanisms and Seismic Vulnerability of Historic Masonry Buildings , 2003 .

[8]  Nelson Lam,et al.  EXPERIMENTAL INVESTIGATION OF UNREINFORCED BRICK MASONRY WALLS IN FLEXURE , 2004 .

[9]  Miha Tomaževič,et al.  Displacement capacity of masonry buildings as a basis for the assessment of behavior factor: an experimental study , 2010 .

[10]  Daniel P. Abrams,et al.  Dynamic response of unreinforced masonry buildings with flexible diaphragms , 1995 .

[11]  John B. Mander,et al.  Seismic performance of an unreinforced masonry building: An experimental investigation , 2009 .

[12]  Eduardo Kausel,et al.  The Impact of High-Frequency/ Low-Energy Seismic Waves on Unreinforced Masonry , 2007 .

[13]  Ioannis N. Psycharis,et al.  Experimental investigation of the earthquake response of a model of a marble classical column , 2002 .

[14]  Aníbal Costa,et al.  Determination of mechanical properties of traditional masonry walls in dwellings of Faial Island, Azores , 2002 .

[15]  Luigi Sorrentino,et al.  Overturning of rocking rigid bodies under transient ground motions , 2006 .

[16]  D. Benedetti,et al.  Shaking table tests on 24 simple masonry buildings , 1998 .

[17]  Nicos Makris,et al.  Rocking response of rigid blocks under near-source ground motions , 2000 .

[18]  Emília Juhásová,et al.  Stone masonry in historical buildings — Ways to increase their resistance and durability , 2008 .

[19]  Aníbal Costa,et al.  Out‐of‐plane behaviour of a full scale stone masonry façade. Part 2: shaking table tests , 2013 .

[20]  P. Lourenço,et al.  Experimental characterization of stone masonry in shear and compression , 2009 .