Islanding detection method adopting single-phase-operating circuit breaker

This study proposes a novel islanding detection method adopting single-phase-operating circuit breaker (CB). The method aims to utilise the operation of CB to generate specific electric information to the distributed generator (DG), instead of using a dedicated signal generator at the substation. When islanding forms, the CB opens three-phase circuits asymmetrically to indicate the islanding, which causes asymmetric operation of the local system within a predefined short time. During this period, negative-sequence voltage with certain duration is obtained at DG side. Furthermore, the varying characteristics of three-phase voltages from close status to open status of CB are the same, which can be utilised to distinguish the formation of islanding from system disturbances. The method is tested based on a typical medium-voltage distribution network with synchronous DG interconnection. Test results show the effectiveness of the proposed method under both islanding formation and system disturbance scenarios.

[1]  N. W. A. Lidula,et al.  A Pattern-Recognition Approach for Detecting Power Islands Using Transient Signals—Part II: Performance Evaluation , 2012, IEEE Transactions on Power Delivery.

[2]  Wilsun Xu,et al.  A Power Line Signaling Based Technique for Anti-Islanding Protection of Distributed Generators—Part I: Scheme and Analysis , 2007, IEEE Transactions on Power Delivery.

[3]  Chung-chuan Hou,et al.  Active anti-islanding detection based on pulse current injection for distributed generation systems , 2013 .

[4]  M. Karrari,et al.  Adaptive Fuzzy Sandia Frequency-Shift Method for Islanding Protection of Inverter-Based Distributed Generation , 2013, IEEE Transactions on Power Delivery.

[5]  Kashem M. Muttaqi,et al.  An Approach for Assessing the Effectiveness of Multiple-Feature-Based SVM Method for Islanding Detection of Distributed Generation , 2014 .

[6]  J. R. McDonald,et al.  UK distribution system protection issues , 2007 .

[7]  Yu Zhang,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2004, IEEE Transactions on Power Electronics.

[8]  Soo Hyoung Lee,et al.  Improvement on Stability and Islanding Detection Performances by Advanced Inverter Control of DG , 2013, IEEE Transactions on Power Systems.

[9]  Wilsun Xu,et al.  A Power Line Signaling Based Scheme for Anti-Islanding Protection of Distributed Generators—Part II: Field Test Results , 2007, IEEE Transactions on Power Delivery.

[10]  J.C.M. Vieira,et al.  An Investigation on the Nondetection Zones of Synchronous Distributed Generation Anti-Islanding Protection , 2008, IEEE Transactions on Power Delivery.

[11]  Wilsun Xu,et al.  Comparative analysis between ROCOF and vector surge relays for distributed generation applications , 2005, IEEE Transactions on Power Delivery.

[12]  Wilsun Xu,et al.  False operation of vector surge relays , 2004, IEEE Transactions on Power Delivery.

[13]  R. S. Bhatia,et al.  Average Absolute Frequency Deviation Value Based Active Islanding Detection Technique , 2015, IEEE Transactions on Smart Grid.

[14]  Hannu Laaksonen,et al.  Advanced Islanding Detection Functionality for Future Electricity Distribution Networks , 2013, IEEE Transactions on Power Delivery.

[15]  Olimpo Anaya-Lara,et al.  Reducing unnecessary disconnection of renewable generation from the power system , 2007 .

[16]  M.H. Nehrir,et al.  A Hybrid Islanding Detection Technique Using Voltage Unbalance and Frequency Set Point , 2007, IEEE Transactions on Power Systems.