All-solid-state carbonate-selective electrode based on a molecular tweezer-type neutral carrier with solvent-soluble conducting polymer solid contact.
暂无分享,去创建一个
Hakhyun Nam | Jeonghan Ha | In Tae Kim | H. Nam | G. Cha | Geun Sig Cha | Fayi Song | Fayi Song | Byungho Park | Tae Hyoung Kwak | J. Ha | In-Tae Kim | Byung-Gook Park | T. Kwak
[1] Yoon,et al. Potentiometric evaluation of solvent polymeric carbonate-selective membranes based on molecular tweezer-type neutral carriers , 2000, Analytical chemistry.
[2] M. Meyerhoff,et al. Response of ion-selective field effect transistors to carbon dioxide and organic acids. , 1985, Analytical chemistry.
[3] Dermot Diamond,et al. Ion sensors: current limits and new trends , 1999 .
[4] A. Ivaska,et al. All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contact , 1994 .
[5] J. Bobacka,et al. Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. , 1999, Analytical chemistry.
[6] Johan Bobacka,et al. Single-piece all-solid-state ion-selective electrode , 1995 .
[7] A. Michalska,et al. All solid-state hydrogen ion-selective electrode based on a conducting poly(pyrrole) solid contact , 1994 .
[8] S. Alegret,et al. Response characteristics of conductive polymer composite substrate all-solid-state poly(vinyl chloride) matrix membrane ion-selective electrodes in aerated and nitrogen-saturated solutions , 1991 .
[9] Johan Bobacka,et al. All‐Solid‐State Chloride‐Selective Electrode Based on Poly(3‐octylthiophene) and Tridodecylmethylammonium Chloride , 1999 .
[10] Frieder W. Scheller,et al. Biosensors and their applications , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).
[11] H. Nam,et al. Enhanced Serum Carbon Dioxide Measurements with a Silicone Rubber-Based Carbonate Ion-Selective Electrode and a High-pH Dilution Buffer. , 1996, Analytical Chemistry.
[12] Elisabeth Verpoorte,et al. Elimination of neutral species interference at the ion-sensitive membrane/semiconductor device interface , 1988 .
[13] A. Machado,et al. Influence of the nature of the support on the temperature ehaviour of “all-solid-state” PVC membrane nitrate ISEs , 1990 .
[14] Dermot Diamond,et al. All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contact , 1992 .
[15] P. Hauser,et al. A potassium-ion selective electrode with valinomycin based poly(vinyl chloride) membrane and a poly(vinyl ferrocene) solid contact , 1995 .
[16] H. Nam,et al. One-component room temperature vulcanizing-type silicone rubber-based calcium-selective electrodes. , 1996, Analytical chemistry.