Three-Dimensional Electrical Impedance Tomography: A Topology Optimization Approach

Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

[1]  Yves Goussard,et al.  Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint , 1997, IEEE Transactions on Medical Imaging.

[2]  Robert V. Kohn,et al.  Numerical implementation of a variational method for electrical impedance tomography , 1990 .

[3]  Thomas C. Ferrée,et al.  Weighted regularization in electrical impedance tomography with applications to acute cerebral stroke , 2002, IEEE Transactions on Medical Imaging.

[4]  J.P. Kaipio,et al.  Three-dimensional electrical impedance tomography based on the complete electrode model , 1999, IEEE Transactions on Biomedical Engineering.

[5]  H. Saunders Book Reviews : NUMERICAL METHODS IN FINITE ELEMENT ANALYSIS K.-J. Bathe and E.L. Wilson Prentice-Hall, Inc, Englewood Cliffs, NJ , 1978 .

[6]  Michael Pidcock,et al.  An image reconstruction algorithm for three-dimensional electrical impedance tomography , 2001, IEEE Transactions on Biomedical Engineering.

[7]  Simon J. Cox,et al.  Efficient Non-Linear 3D Electrical Tomography Reconstruction , 2001 .

[8]  Charles John Phillips Glass : its industrial applications , 1960 .

[9]  W J Tompkins,et al.  Electrical impedance imaging of the thorax. , 1983, The Journal of microwave power.

[10]  J C Newell,et al.  Real-time three-dimensional electrical impedance imaging. , 2000, Physiological measurement.

[11]  Emílio C. N. Silva,et al.  Optimization of material distribution in functionally graded structures with stress constraints , 2006 .

[12]  Marko Vauhkonen,et al.  Simultaneous reconstruction of electrode contact impedances and internal electrical properties: II. Laboratory experiments , 2002 .

[13]  P. Hua,et al.  Finite element modeling of electrode-skin contact impedance in electrical impedance tomography , 1993, IEEE Transactions on Biomedical Engineering.

[14]  Luís Augusto Motta Mello Estudo da obtenção de imagens tridimensionais de tomografia por impedância elétrica pelo método de otimização topológica , 2005 .

[15]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[16]  Tzu-Jen Kao,et al.  A 3D reconstruction algorithm for EIT using a handheld probe for breast cancer detection , 2006, Physiological measurement.

[17]  R. H. Smallwood,et al.  Neonatal lungs-can absolute lung resistivity be determined non-invasively? , 2002, Medical and Biological Engineering and Computing.

[18]  Jari P. Kaipio,et al.  Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory , 2002 .

[19]  Raul Gonzalez Lima,et al.  Regularizations for a Black Box Back-projection EIT algorithm , 2006 .

[20]  Raul Gonzalez Lima,et al.  Electrical impedance tomography using the extended Kalman filter , 2004, IEEE Transactions on Biomedical Engineering.

[21]  K. Bathe Finite Element Procedures , 1995 .

[22]  K. Matsui,et al.  Continuous approximation of material distribution for topology optimization , 2004 .

[23]  R. Haftka,et al.  Elements of Structural Optimization , 1984 .

[24]  M. Neuman,et al.  Impedance computed tomography algorithm and system. , 1985, Applied optics.

[25]  E. Somersalo,et al.  Statistical inversion and Monte Carlo sampling methods in electrical impedance tomography , 2000 .

[26]  E. Somersalo,et al.  Using process tomography as a sensor for optimal control , 2006 .

[27]  David Barber,et al.  Three dimensional electrical impedance tomography of the human thorax , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  James K. Guest,et al.  Achieving minimum length scale in topology optimization using nodal design variables and projection functions , 2004 .

[29]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .