Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with load-bearing 'rigid' (high stiffness) porous implants on the right side, and with control on the left side. A second group of 6 ewes (group B) was treated with 'flexible' porous and control implants exhibiting apparent mechanical properties ten times lower than the rigid implants. The mechanical behavior of the reconstructed hemi-mandibles was assessed by cantilever testing and bone ingrowth into the segmental defects was assessed by BV/TV measurement within the implant using micro-CT 12 weeks after implantation. A significantly higher rigidity was identified for porous implants compared with control implants at the anterior interface in group B. BV/TV of porous implants was significantly higher than that of control implants in group A. BV/TV differences were significant between porous and control implants in group B and were homogeneous along the main axis. Significantly higher BV/TV was identified in most sub-volumes of group B porous implants compared with group A. This work highlights the critical importance of the tuning of scaffolds to promote bone ingrowth with reference to the local strains occurring within the porous scaffold, which in this application was achieved using fully load-bearing low-stiffness porous titanium implants.

[1]  Naoyuki Nomura,et al.  Mechanical properties of porous titanium compacts prepared by powder sintering , 2003 .

[2]  Pierre Layrolle,et al.  Rapid prototyped porous titanium coated with calcium phosphate as a scaffold for bone tissue engineering. , 2008, Biomaterials.

[3]  M. Neo,et al.  Osteoinduction of porous bioactive titanium metal. , 2004, Biomaterials.

[4]  P H Krebsbach,et al.  Engineering craniofacial scaffolds. , 2005, Orthodontics & craniofacial research.

[5]  Tadashi Kokubo,et al.  Mechanical properties and osteoconductivity of porous bioactive titanium. , 2005, Biomaterials.

[6]  Tomohiro Yamada,et al.  Custom-made titanium devices as membranes for bone augmentation in implant treatment: Modeling accuracy of titanium products constructed with selective laser melting. , 2015, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[7]  M. Archdeacon,et al.  Autogenous bone graft: donor sites and techniques. , 2011, The Journal of bone and joint surgery. American volume.

[8]  Maryam Tabrizian,et al.  Three-dimensional growth of differentiating MC3T3-E1 pre-osteoblasts on porous titanium scaffolds. , 2005, Biomaterials.

[9]  Jos Vander Sloten,et al.  Micro-CT-based screening of biomechanical and structural properties of bone tissue engineering scaffolds , 2006, Medical and Biological Engineering and Computing.

[10]  C. Wen,et al.  Bone formation following implantation of titanium sponge rods into humeral osteotomies in dogs: a histological and histometrical study. , 2010, Clinical implant dentistry and related research.

[11]  A. Giatromanolaki,et al.  Mechanical characterization of bone graft substitute ceramic cements. , 2012, Injury.

[12]  J. Jansen,et al.  Bone formation in calcium-phosphate-coated titanium mesh. , 2000, Biomaterials.

[13]  M Browne,et al.  Long-term biocompatibility and osseointegration of electron beam melted, free-form–fabricated solid and porous titanium alloy: Experimental studies in sheep , 2013, Journal of biomaterials applications.

[14]  P Zioupos,et al.  Effect of formaldehyde fixation on some mechanical properties of bovine bone. , 1995, Biomaterials.

[15]  T. Schouman,et al.  Acute compartment syndrome following fibula flap harvest for mandibular reconstruction. , 2011, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[16]  Ping Liu,et al.  Porous titanium materials with entangled wire structure for load-bearing biomedical applications. , 2012, Journal of the mechanical behavior of biomedical materials.

[17]  D. Kaplan,et al.  Porosity of 3D biomaterial scaffolds and osteogenesis. , 2005, Biomaterials.

[18]  B Vamsi Krishna,et al.  Processing and biocompatibility evaluation of laser processed porous titanium. , 2007, Acta biomaterialia.

[19]  R. Bader,et al.  Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep. , 2015, Biomaterials.

[20]  J. V. Ver Halen A prospective cohort study of fibula free flap donor-site morbidity in 157 consecutive patients. , 2012, Plastic and reconstructive surgery.

[21]  A. Lanzutti,et al.  Characterization of grade 2 commercially pure Trabecular Titanium structures. , 2013, Materials science & engineering. C, Materials for biological applications.

[22]  大槻 文悟,et al.  Pore throat size and connectivity determine bone and tissue ingrowth into porous implants : three-dimensional micro-CT based structural analyses of porous bioactive titanium implants , 2007 .

[23]  Ralf Schumacher,et al.  Bone regeneration by the osteoconductivity of porous titanium implants manufactured by selective laser melting: a histological and micro computed tomography study in the rabbit. , 2013, Tissue engineering. Part A.

[24]  Henk Tideman,et al.  Mandibular reconstruction in adults: a review. , 2008, International journal of oral and maxillofacial surgery.

[25]  F. Blake,et al.  Long-term donor-site morbidity after microsurgical fibular graft: is there a difference between the medial approach and the lateral approach? , 2012, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[26]  Ping Liu,et al.  Flexural and compressive mechanical behaviors of the porous titanium materials with entangled wire structure at different sintering conditions for load-bearing biomedical applications. , 2013, Journal of the mechanical behavior of biomedical materials.

[27]  P. Lipinski,et al.  Development and mechanical characterization of porous titanium bone substitutes. , 2012, Journal of the mechanical behavior of biomedical materials.

[28]  K. Weimer,et al.  Computer planning and intraoperative navigation for palatomaxillary and mandibular reconstruction with fibular free flaps. , 2011, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[29]  K. Weimer,et al.  Use of computer-aided design and computer-aided manufacturing to produce orthognathically ideal surgical outcomes: a paradigm shift in head and neck reconstruction. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[30]  Emeka Nkenke,et al.  In vivo performance of selective electron beam-melted Ti-6Al-4V structures. , 2010, Journal of biomedical materials research. Part A.

[31]  J. Jansen,et al.  Ectopic bone formation in titanium mesh loaded with bone morphogenetic protein and coated with calcium phosphate. , 2001, Plastic and reconstructive surgery.

[32]  Jos Vander Sloten,et al.  Three-dimensional finite element models based on in vivo microfocus computed tomography: Elimination of metal artefacts in a small laboratory animal model by registration with artefact-free reference images , 2009, Adv. Eng. Softw..

[33]  Timothy Douglas,et al.  Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering. , 2009, Tissue engineering. Part C, Methods.

[34]  M. Niinomi,et al.  Titanium-Based Biomaterials for Preventing Stress Shielding between Implant Devices and Bone , 2011, International journal of biomaterials.

[35]  M Abu-Serriah,et al.  Mechanical evaluation of mandibular defects reconstructed using osteogenic protein-1 (rhOP-1) in a sheep model: a critical analysis. , 2005, International journal of oral and maxillofacial surgery.

[36]  M. Pogrel,et al.  Vascularized bone flaps versus nonvascularized bone grafts for mandibular reconstruction: An outcome analysis of primary bony union and endosseous implant success , 1999, Head & neck.

[37]  Tadashi Kokubo,et al.  Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants. , 2006, Biomaterials.

[38]  Daniel G Deschler,et al.  Mandibular reconstruction in 2004: an analysis of different techniques , 2004, Current opinion in otolaryngology & head and neck surgery.

[39]  R. Khonsari,et al.  Shaping the fibula without fumbling: the SynpliciTi customised guide-plate. , 2015, The British journal of oral & maxillofacial surgery.

[40]  A. A. Zadpoor,et al.  Selective laser melting‐produced porous titanium scaffolds regenerate bone in critical size cortical bone defects , 2013, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[41]  M. Hanasono,et al.  A Prospective Cohort Study of Fibula Free Flap Donor-Site Morbidity in 157 Consecutive Patients , 2011, Plastic and reconstructive surgery.