Amplitude cancellation of motor-unit action potentials in the surface electromyogram can be estimated with spike-triggered averaging.

The study presents analytical, simulation, and experimental analyses of amplitude cancellation of motor-unit action potentials (APs) in the interference electromyogram (EMG) and its relation to the size of the spike-triggered average (STA) EMG. The amount of cancellation of motor-unit APs decreases monotonically as a function of the ratio between the root mean square (RMS) of the motor-unit AP and the RMS of the interference EMG signal. The theoretical derivation of this association indicates a method to measure cancellation in individual motor units by STA of the interference and squared EMGs. The theoretical relation was examined in both simulated EMG signals generated by populations of 200 motor units and experimental recordings of 492 and 184 motor-unit APs in the vastus medialis and abductor digiti minimi muscles, respectively. Although the theoretical relation predicted (R2 = 0.95; P < 0.001) the amount of cancellation in the simulated EMGs, the presence of motor-unit synchronization decreased the strength of the association for small APs. The decrease in size of the STA obtained from the squared EMG relative to that extracted from the interference EMG was predicted by the experimental measure of cancellation (R2 = 0.65; P < 0.001, for vastus medialis; R2 = 0.26; P < 0.05, for abductor digiti minimi). The results indicate that cancellation of APs in the interference EMG can be analytically predicted and experimentally measured with STA from the discharge times of the motor units into the surface EMG.

[1]  R. Enoka,et al.  Motor unit recruitment and bursts of activity in the surface electromyogram during a sustained contraction , 2008, Muscle & nerve.

[2]  D. Farina,et al.  The linear electrode array: a useful tool with many applications. , 2003, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[3]  Naoichi Chino,et al.  Synchronization of single motor units during voluntary contractions in the upper and lower extremities , 2001, Clinical Neurophysiology.

[4]  R. Cantello,et al.  Conduction velocity along human muscle fibers in situ , 1983, Neurology.

[5]  Discrimination of different motor units by spike-triggered averaging of surface electromyograms , 1991, Neuroscience Letters.

[6]  R. Dengler,et al.  Parameters of human motor unit twitches obtained by intramuscular microstimulation , 1992, Neuromuscular Disorders.

[7]  J F Yang,et al.  Methods for estimating the number of motor units in human muscles , 1990, Annals of neurology.

[8]  R. Person,et al.  Discharge frequency and discharge pattern of human motor units during voluntary contraction of muscle. , 1972, Electroencephalography and clinical neurophysiology.

[9]  P. Rosenfalck Intra- and extracellular potential fields of active nerve and muscle fibres. A physico-mathematical analysis of different models. , 1969, Acta physiologica Scandinavica. Supplementum.

[10]  D. Kernell,et al.  SYNAPTIC INFLUENCE ON THE REPETITIVE ACTIVITY ELICITED IN CAT LUMBOSACRAL MOTONEURONES BY LONG-LASTING INJECTED CURRENTS. , 1965, Acta physiologica Scandinavica.

[11]  Michael A. Nordstrom,et al.  Relationship between motor unit short-term synchronization and common drive in human first dorsal interosseous muscle , 1997, Brain Research.

[12]  Dario Farina,et al.  Amplitude cancellation reduces the size of motor unit potentials averaged from the surface EMG. , 2006, Journal of applied physiology.

[13]  G. A. Robinson,et al.  Behavior of motor units in human biceps brachii during a submaximal fatiguing contraction. , 1994, Journal of applied physiology.

[14]  R. Stein,et al.  Statistical limits for detecting change in the cumulative sum derivative of the peristimulus time histogram , 1986, Journal of Neuroscience Methods.

[15]  A J Fuglevand,et al.  Impairment of neuromuscular propagation during human fatiguing contractions at submaximal forces. , 1993, The Journal of physiology.

[16]  William J Kraemer,et al.  Neural factors account for strength decrements observed after short-term muscle unloading. , 2002, American journal of physiology. Regulatory, integrative and comparative physiology.

[17]  Dario Farina,et al.  A surface EMG generation model with multilayer cylindrical description of the volume conductor , 2004, IEEE Transactions on Biomedical Engineering.

[18]  Roberto Merletti,et al.  Selectivity of spatial filters for surface EMG detection from the tibialis anterior muscle , 2003, IEEE Transactions on Biomedical Engineering.

[19]  Ping Zhou,et al.  Factors governing the form of the relation between muscle force and the EMG: a simulation study. , 2004, Journal of neurophysiology.

[20]  J Hanson,et al.  Changes in the action potential and contraction of isolated frog muscle after repetitive stimulation. , 1971, Acta physiologica Scandinavica.

[21]  Roger M Enoka,et al.  Motor-unit activity differs with load type during a fatiguing contraction. , 2005, Journal of neurophysiology.

[22]  D. Farina,et al.  Motor unit conduction velocity during sustained contraction of the vastus medialis muscle , 2007, Experimental Brain Research.

[23]  R. Enoka,et al.  Influence of amplitude cancellation on the simulated surface electromyogram. , 2005, Journal of applied physiology.

[24]  R. Stein,et al.  Synchronization of human motor units: possible roles of exercise and supraspinal reflexes. , 1975, Electroencephalography and clinical neurophysiology.

[25]  Dario Farina,et al.  Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays , 2000, IEEE Transactions on Biomedical Engineering.

[26]  B. Bigland-ritchie,et al.  Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[27]  C J De Luca,et al.  Synchronization of motor-unit firings in several human muscles. , 1993, Journal of neurophysiology.

[28]  Roger M. Enoka,et al.  Limitations of the surface electromyography technique for estimating motor unit synchronization , 1995, Biological Cybernetics.

[29]  A J Fuglevand,et al.  Estimating the strength of common input to human motoneurons from the cross‐correlogram. , 1992, The Journal of physiology.

[30]  P H Ellaway,et al.  Cumulative sum technique and its application to the analysis of peristimulus time histograms. , 1978, Electroencephalography and clinical neurophysiology.

[31]  R. Enoka,et al.  Motor-unit synchronization increases EMG amplitude and decreases force steadiness of simulated contractions. , 2000, Journal of neurophysiology.

[32]  M D Binder,et al.  Computer simulation of the steady-state input-output function of the cat medial gastrocnemius motoneuron pool. , 1991, Journal of neurophysiology.

[33]  C A Laszlo,et al.  A review of techniques employed to estimate the number of motor units in a muscle , 1990, Muscle & nerve.

[34]  Kevin C. McGill,et al.  EMGLAB: An interactive EMG decomposition program , 2005, Journal of Neuroscience Methods.

[35]  S. Andreassen,et al.  Muscle fibre conduction velocity in motor units of the human anterior tibial muscle: a new size principle parameter. , 1987, The Journal of physiology.

[36]  M J Campbell,et al.  Electrophysiological estimation of the number of motor units within a human muscle , 1971, Journal of neurology, neurosurgery, and psychiatry.

[37]  C. D. De Luca,et al.  Behaviour of human motor units in different muscles during linearly varying contractions , 1982, The Journal of physiology.

[38]  S. Farmer,et al.  Central nervous pathways underlying synchronization of human motor unit firing studied during voluntary contractions. , 1991, The Journal of physiology.

[39]  R. Stein,et al.  The contractile properties of human motor units during voluntary isometric contractions , 1973, The Journal of physiology.

[40]  D. Winter,et al.  Models of recruitment and rate coding organization in motor-unit pools. , 1993, Journal of neurophysiology.

[41]  Tadashi Masuda,et al.  The Position of Innervation Zones in the Biceps Brachii Investigated by Surface Electromyography , 1985, IEEE Transactions on Biomedical Engineering.

[42]  F. Richmond,et al.  Compartmentalization of motor units in the cat neck muscle, biventer cervicis. , 1988, Journal of neurophysiology.

[43]  C. Moritz,et al.  Discharge rate variability influences the variation in force fluctuations across the working range of a hand muscle. , 2005, Journal of neurophysiology.

[44]  Dario Farina,et al.  Influence of motor unit properties on the size of the simulated evoked surface EMG potential , 2006, Experimental Brain Research.

[45]  Knaflitz,et al.  Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions. , 1990, Journal of applied physiology.

[46]  S J Day,et al.  Experimental simulation of cat electromyogram: evidence for algebraic summation of motor-unit action-potential trains. , 2001, Journal of neurophysiology.

[47]  G V Dimitrov,et al.  Amplitude-related characteristics of motor unit and M-wave potentials during fatigue. A simulation study using literature data on intracellular potential changes found in vitro. , 2002, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[48]  Michael A Nordstrom,et al.  A comparison of cross-correlation and surface EMG techniques used to quantify motor unit synchronization in humans , 1999, Journal of Neuroscience Methods.

[49]  D. Farina,et al.  Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging , 2002, Journal of Neuroscience Methods.