Patient-specific simulation of a stentless aortic valve implant: the impact of fibres on leaflet performance

In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity, avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly dependent on an appropriate choice of both prosthesis size and replacement technique, which is, at present, strictly related to surgeon's experience and skill. This represents the motivation for patient-specific finite element analysis able to virtually reproduce stentless valve implantation. With the aim of performing reliable patient-specific simulations, we remark that, on the one hand, it is not well established in the literature whether bioprosthetic leaflet tissue is isotropic or anisotropic; on the other hand, it is of fundamental importance to incorporate an accurate material model to realistically predict post-operative performance. Within this framework, using a novel computational methodology to simulate stentless valve implantation, we test the impact of using different material models on both the stress pattern and post-operative coaptation parameters (i.e. coaptation area, length and height). As expected, the simulation results suggest that the material properties of the valve leaflets affect significantly the post-operative prosthesis performance.

[1]  D. Chachra,et al.  Effect of applied uniaxial stress on rate and mechanical effects of cross-linking in tissue-derived biomaterials. , 1996, Biomaterials.

[2]  F. Sánchez-Arévalo,et al.  The micromechanical behavior of lyophilized glutaraldehyde-treated bovine pericardium under uniaxial tension. , 2010, Journal of the mechanical behavior of biomedical materials.

[3]  Alberto Redaelli,et al.  Aortic root performance after valve sparing procedure: a comparative finite element analysis. , 2009, Medical engineering & physics.

[4]  F Auricchio,et al.  A computational tool to support pre-operative planning of stentless aortic valve implant. , 2011, Medical engineering & physics.

[5]  S L Zeger,et al.  An approach to quantification of biaxial tissue stress-strain data. , 1986, Journal of biomechanics.

[6]  B. Reddy,et al.  Aortic valve leaflet mechanical properties facilitate diastolic valve function , 2010, Computer methods in biomechanics and biomedical engineering.

[7]  Nobutada Ohno,et al.  Implementation of cyclic plasticity models based on a general form of kinematic hardening , 2002 .

[8]  J. Nagtegaal On the implementation of inelastic constitutive equations with special reference to large deformation problems , 1982 .

[9]  Alexander Kulik,et al.  Mechanical versus bioprosthetic valve replacement in middle-aged patients. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  Matti Ristinmaa,et al.  An alternative method for the integration of continuum damage evolution laws , 2007 .

[11]  Matti Ristinmaa,et al.  Accurate stress updating algorithm based on constant strain rate assumption , 2001 .

[12]  D R Boughner,et al.  The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium. , 1989, Journal of biomedical materials research.

[13]  F Auricchio,et al.  Finite element analysis of aortic root dilation: a new procedure to reproduce pathology based on experimental data , 2011, Computer methods in biomechanics and biomedical engineering.

[14]  J. C. Barbenel,et al.  Mechanical and optical anisotropy of bovine pericardium , 2006, Medical and Biological Engineering and Computing.

[15]  E. A. Trowbridge,et al.  The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load , 1985 .

[16]  S. Remseth,et al.  A return mapping algorithm for a class of cyclic plasticity models , 1995 .

[17]  Thomas Walther,et al.  The aortic root , 2010 .

[18]  Francesco Genna,et al.  Accurate numerical integration of Drucker-Prager's constitutive equations , 1994 .

[19]  M. Sacks,et al.  Collagen fiber architecture of bovine pericardium. , 1994, ASAIO journal.

[20]  Chein-Shan Liu,et al.  Internal symmetry groups for the Drucker-Prager material model of plasticity and numerical integrating methods , 2004 .

[21]  J. Gummert,et al.  Quality of Life after Mechanical vs. Biological Aortic Valve Replacement , 2005, Asian cardiovascular & thoracic annals.

[22]  E A Trowbridge,et al.  The extension rate independence of the hysteresis in glutaraldehyde-fixed bovine pericardium. , 1987, Biomaterials.

[23]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[24]  R. P. Cochran,et al.  Dynamic Finite Element Implementation of Nonlinear, Anisotropic Hyperelastic Biological Membranes , 2003, Computer methods in biomechanics and biomedical engineering.

[25]  M. Sacks,et al.  Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: Experimental results. , 2000, Journal of biomechanical engineering.

[26]  Erich Wintermantel,et al.  Finite Element Investigation of Stentless Pericardial Aortic Valves: Relevance of Leaflet Geometry , 2010, Annals of Biomedical Engineering.

[27]  D. Mozaffarian,et al.  Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[28]  C. Vosa,et al.  Aortic valve replacement: a prospective randomized evaluation of mechanical versus biological valves in patients ages 55 to 70 years. , 2009, Journal of the American College of Cardiology.

[29]  Thierry Carrel,et al.  The Sorin Freedom SOLO stentless aortic valve: technique of implantation and operative results in 109 patients. , 2010, The Journal of thoracic and cardiovascular surgery.

[30]  Frank P T Baaijens,et al.  A structural constitutive model for collagenous cardiovascular tissues incorporating the angular fiber distribution. , 2005, Journal of biomechanical engineering.

[31]  Ferdinando Auricchio,et al.  Second-order accurate integration algorithms for von-Mises plasticity with a nonlinear kinematic hardening mechanism , 2007 .

[32]  D. C. Drucker,et al.  Soil mechanics and plastic analysis or limit design , 1952 .

[33]  Ferdinando Auricchio,et al.  Integration schemes for von‐Mises plasticity models based on exponential maps: numerical investigations and theoretical considerations , 2005 .

[34]  Matti Ristinmaa,et al.  EXACT INTEGRATION OF CONSTITUTIVE EQUATIONS IN ELASTO - PLASTICITY , 1993 .

[35]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2010 update: a report from the American Heart Association. , 2010, Circulation.

[36]  J Fisher,et al.  Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valves. , 1994, Journal of biomedical materials research.

[37]  R. Chernecky,et al.  Biaxial mechanical/structural effects of equibiaxial strain during crosslinking of bovine pericardial xenograft materials. , 1999, Biomaterials.

[38]  A Corvi,et al.  Functional analysis of bioprosthetic heart valves. , 2005, Journal of biomechanics.

[39]  D R Boughner,et al.  Tissue Mechanics of Canine Pericardium in Different Test Environments: Evidence for Time‐Dependent Accommodation, Absence of Plasticity, and New Roles for Collagen and Elastin , 1981, Circulation research.

[40]  A. Ranga,et al.  A Compliant Dynamic FEA Model of the Aortic Valve , 2007 .

[41]  O. Yeoh Some Forms of the Strain Energy Function for Rubber , 1993 .

[42]  K S Kunzelman,et al.  Re-creation of sinuses is important for sparing the aortic valve: a finite element study. , 2000, The Journal of thoracic and cardiovascular surgery.

[43]  Jean-Herve Prevost,et al.  Accurate numerical solutions for Drucker-Prager elastic-plastic models , 1986 .

[44]  Mohammad Rezaiee-Pajand,et al.  Accurate integration scheme for von‐Mises plasticity with mixed‐hardening based on exponential maps , 2007 .

[45]  Jia Lu,et al.  Dynamic simulation pericardial bioprosthetic heart valve function. , 2006, Journal of biomechanical engineering.

[46]  Michel R Labrosse,et al.  Geometric modeling of functional trileaflet aortic valves: development and clinical applications. , 2006, Journal of biomechanics.

[47]  Mohammad Rezaiee-Pajand,et al.  Accurate and approximate integrations of Drucker–Prager plasticity with linear isotropic and kinematic hardening , 2011 .

[48]  J. Lowe,et al.  Long-term outcome after biologic versus mechanical aortic valve replacement in 841 patients. , 1999, The Journal of thoracic and cardiovascular surgery.

[49]  Mohammad Rezaiee-Pajand,et al.  A novel formulation for integrating nonlinear kinematic hardening Drucker-Prager’s yield condition , 2012 .

[50]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[51]  A. Wiegner,et al.  Mechanical and Structural Correlates of Canine Pericardium , 1981, Circulation research.

[52]  K. O. Lim,et al.  Anisotropic elasticity of bovine pericardial tissues. , 1985, The Japanese journal of physiology.

[53]  Ferdinando Auricchio,et al.  A novel ‘optimal’ exponential‐based integration algorithm for von‐Mises plasticity with linear hardening: Theoretical analysis on yield consistency, accuracy, convergence and numerical investigations , 2006 .