An Experimental Study of Small-Diameter Wickless Heat Pipes Operating in the Temperature Range 200°C to 450°C

An experimental investigation is reported for medium-temperature, wickless, small-diameter heat pipes charged with environmentally sound and commercially available working fluids. The wickless heat pipes (thermosyphons) studied have many applications in heat recovery systems since their operational temperature range is between 200°C and 450°C. The heat pipes investigated had an internal diameter of 6 mm and a length of 209 mm. The lengths of evaporator and condenser sections were 50 mm and 100 mm, respectively. The working fluids tested were diphenyl based: Therminol VP1 and Dowtherm A. High-grade stainless steel was chosen as the shell material for the heat pipes to provide chemical compatibility between heat pipe casing material and working fluids at elevated temperatures. Thermal resistances of less than 0.4 K/W have been achieved at working temperatures of up to 420°C with an effective thermal conductivity of 20 kW/m-K, which corresponds to an axial heat flux of 2.5 MW/m2. Even for such small-diameter heat pipes, the experimental data for the evaporator showed good agreement with Rohsenow's pool boiling correlation.

[1]  W. Rohsenow A Method of Correlating Heat-Transfer Data for Surface Boiling of Liquids , 1952, Journal of Fluids Engineering.

[2]  U. Mital,et al.  A two-phase closed thermosyphon , 1972 .

[3]  P. Štulc,et al.  Heat pipes for the temperature range from 200 to 600 C , 1976 .

[4]  D. D. Kenney,et al.  Heat pipe life tests at temperatures up to 400 C , 1978 .

[5]  M. Shiraishi,et al.  Investigation of Heat Transfer Characteristics of a Two-Phase Closed Thermosyphon , 1981 .

[6]  Aliakbar Akbarzadeh,et al.  The thermal characteristics of a closed two-phase thermosyphon at low temperature difference , 1991 .

[7]  T. Wadowski,et al.  Hysteresis in thermosyphon-based heat exchangers and introduction of a novel triggering system for low-temperature difference heat-recovery applications , 1991 .

[8]  Amir Faghri,et al.  Heat Pipe Science And Technology , 1995 .

[9]  J. J. Bland,et al.  High temperature loop heat pipes , 1995 .

[10]  P. Johnson,et al.  Design, construction and testing of a thermosyphon heat exchanger for medium temperature heat recovery in bakeries , 1995 .

[11]  Ioan Sauciuc,et al.  Characteristics of two-phase closed thermosiphons for medium temperature heat recovery applications , 1995 .

[12]  Khalid A. Joudi,et al.  Improvements of gravity assisted wickless heat pipes , 2000 .

[13]  Yiding Cao,et al.  Closed-form analytical solutions for radially rotating miniature high-temperature heat pipes including non-condensable gas effects , 2000 .

[14]  Hosny Z. Abou-Ziyan,et al.  Performance of stationary and vibrated thermosyphon working with water and R134a , 2001 .

[15]  K. S. Ong,et al.  Performance of a R-134a-filled thermosyphon , 2003 .

[16]  Angirasa Devarakonda An Evaluation of Halides and Other Substances as Potential Heat Pipe Fluids , 2004 .

[17]  D. Angirasa,et al.  Evaluation of Heat Pipe Working Fluids In The Temperature Range 450 to 700 K , 2004 .

[18]  S. H. Noie Heat transfer characteristics of a two-phase closed thermosyphon , 2005 .

[19]  William G. Anderson,et al.  Thermo‐Physical Properties of Intermediate Temperature Heat Pipe Fluids , 2005 .