Validation of the Microbiological Testing of Tissue Preparations Using the BACTECTM Blood Culture System

Background: Since blood culture bottles are validated by the manufacturer for blood only, an additional validation for the use with fluids of tissue preparations is necessary. Methods: Two 10-ml samples of cornea culture medium, histidine-tryptophan-ketoglutarate (HTK) solution, or Ringer solution at the end of femur head thermo-disinfection were given into blood culture bottles (BD BACTECTM Plus Aerobic/F, Anaerobic/F for cornea culture medium and BD BACTECTM Standard Aerobic/ Anaerobic for HTK and Ringer solution) and subsequently spiked with 10–100 colony forming units (CFU) of bacteria or fungi (aerobic bacteria: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa; anaerobic bacteria: Clostridium sporogenes; fungi: Candida albicans, Aspergillus brasiliensis) according to the European Pharmacopoeia Chapter 2.6.1. Results: All tested bacteria and fungi could be detected in all solutions. All positive and negative controls were tested correctly. Compared to the positive controls, the microbial growth was delayed in the antibiotic-containing cornea culture medium, and negative in two cases of B. subtilis spiking. Conclusion: The use of BACTECTM blood culture bottles seems to be a suitable method for microbiological testing of HTK solution, Ringer solution, and, with limitations, also for testing of the antibiotic-containing cornea culture medium.

[1]  G. Vrensen,et al.  Microbial decontamination of human donor eyes with povidone-iodine: penetration, toxicity, and effectiveness , 1999, The British journal of ophthalmology.

[2]  L. Frommelt,et al.  Validation of the 'Marburg bone bank system' for thermodisinfection of allogenic femoral head transplants using selected bacteria, fungi, and spores. , 2003, Biologicals : journal of the International Association of Biological Standardization.

[3]  O. Damour,et al.  Validation of the BacT/ALERT®3D automated culture system for the detection of microbial contamination of epithelial cell culture medium , 2011, Cell and Tissue Banking.

[4]  P. Gain,et al.  Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media , 2005, British Journal of Ophthalmology.

[5]  B. Nzeako,et al.  Evaluation of the neutralising capacity of Bactec medium for some antibiotics , 2004, British journal of biomedical science.

[6]  M. Weinstein,et al.  General principles in the laboratory detection of bacteremia and fungemia. , 1994, Clinics in laboratory medicine.

[7]  T. Reinhard,et al.  [Corneoscleral transplant excision in the cadaver. Experiences of the North Rhine Westphalia Lions Cornea Bank 1995 and 1996]. , 1997, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[8]  M. Wilson Blood cultures. Introduction. , 1994, Clinics in laboratory medicine.

[9]  D. Ponzin,et al.  Bacterial Contamination of Human Organ-Cultured Corneas , 2005, Cornea.

[10]  K. Carroll,et al.  Comparison of BACTEC PLUS Blood Culture Media to BacT/Alert FA Blood Culture Media for Detection of Bacterial Pathogens in Samples Containing Therapeutic Levels of Antibiotics , 2006, Journal of Clinical Microbiology.

[11]  R. H. Keates,et al.  Bacterial contamination of donor eyes. , 1977, American journal of ophthalmology.

[12]  P. Gain,et al.  Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi , 2002, The British journal of ophthalmology.

[13]  J. Dyke,et al.  Enhanced detection of bacteremia with a new BACTEC resin blood culture medium , 1983, Journal of clinical microbiology.

[14]  C. Wallis,et al.  Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device , 1980, Journal of clinical microbiology.

[15]  T. Reinhard,et al.  In situ corneal excision – Experience of the Lions Cornea Bank of Nordrhein-Westfalen in 1995 and 1996 , 1997, Der Ophthalmologe.