Combined Planar Magnetic Induction Tomography for Local Detection of Intracranial Hemorrhage

Magnetic induction tomography (MIT) is a contactless and harmless technique for intracranial hemorrhage detection. Due to the low electrical conductivity of biological tissues, the phase shift signals are very weak. To improve the sensitivity of the phase shift signals and achieve the local detection of intracranial hemorrhage, a planar MIT method is proposed. The coil parameters were optimized based on the sensitivity analysis. The performance of single planar and combined planar MITs was investigated with a 3-D anatomical head model. Two evaluation indexes, correlation coefficient <inline-formula> <tex-math notation="LaTeX">$\text {cc}_{\text {ima}}$ </tex-math></inline-formula> and localization error <inline-formula> <tex-math notation="LaTeX">$L_{e}$ </tex-math></inline-formula>, were introduced to evaluate the imaging quality. Finally, experimental tests were carried out to verify the ability of combined planar MIT for hemorrhage detection. The simulation results indicate that the combined planar MIT has better imaging quality and distinguishing ability for the hemorrhage with different deviation positions, depths, and volumes. For the 8-mL hemorrhage, <inline-formula> <tex-math notation="LaTeX">$\text {cc}_{\text {ima}}$ </tex-math></inline-formula> of combined planar MIT is increased by 40.2%, and <inline-formula> <tex-math notation="LaTeX">$L_{e}$ </tex-math></inline-formula> is reduced by 77.8% compared with single planar MIT. The experimental results indicate that a 16-mL hemorrhage can be reconstructed, and the change in position can be distinguished by combined planar MIT. The study demonstrates that combined planar MIT is a feasible method for hemorrhage detection. The proposed method provides a portable solution for local detection of intracranial hemorrhage and promotes the practical application of MIT in biomedical imaging.

[1]  Min Han,et al.  Magnetic Induction Tomography , 2015 .

[2]  Boris Rubinsky,et al.  Non-Contact Monitoring of Temporal Volume Changes of a Hematoma in the Head by a Single Inductive Coil: A Numerical Study , 2019, IEEE Transactions on Biomedical Engineering.

[3]  Raul G Nogueira,et al.  Spontaneous intracerebral hemorrhage. , 1992, Neurosurgery clinics of North America.

[4]  O Dössel,et al.  Design and performance of a planar-array MIT system with normal sensor alignment. , 2005, Physiological measurement.

[5]  Nevzat G. Gencer,et al.  Electrical conductivity imaging via contactless measurements: an experimental study , 2003, IEEE Transactions on Medical Imaging.

[6]  Feng Dong,et al.  Optimization of Dual Frequency-Difference MIT Sensor Array Based on Sensitivity and Resolution Analysis , 2018, IEEE Access.

[7]  Hermann Scharfetter,et al.  Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability. , 2004, Physiological measurement.

[8]  H Griffiths,et al.  Magnetic Induction Tomography: A Measuring System for Biological Tissues , 1999, Annals of the New York Academy of Sciences.

[9]  Feng Dong,et al.  Sensitivity Comparison of a Cambered Magnetic Induction Tomography for Local Hemorrhage Detection , 2018, 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[10]  Jochen B. Fiebach,et al.  Intracranial hemorrhage , 2004, Neurocritical care.

[11]  Jingbo Chen,et al.  Detection of rabbit intracranial hemorrhage based on permittivity , 2019, Measurement Science and Technology.

[12]  Ze Liu,et al.  A novel algorithm based on L1-L norm for inverse problem of electromagnetic tomography , 2019, Flow Measurement and Instrumentation.

[13]  A Korjenevsky,et al.  Magnetic induction tomography: experimental realization. , 2000, Physiological measurement.

[14]  Doga Gursoy,et al.  Imaging artifacts in magnetic induction tomography caused by the structural incorrectness of the sensor model , 2011 .

[15]  Patricia Brunner,et al.  Solution of the inverse problem of magnetic induction tomography (MIT) , 2005, Physiological measurement.

[16]  O Dössel,et al.  A comparison of sensors for minimizing the primary signal in planar-array magnetic induction tomography. , 2005, Physiological measurement.

[17]  R. Keep,et al.  Intracerebral haemorrhage: mechanisms of injury and therapeutic targets , 2012, The Lancet Neurology.

[18]  Yonggui Dong,et al.  Design of a Magnetic Induction Tomography System by Gradiometer Coils for Conductive Fluid Imaging , 2019, IEEE Access.

[19]  H Scharfetter,et al.  Sensitivity maps and system requirements for magnetic induction tomography using a planar gradiometer. , 2001, Physiological measurement.

[20]  Manuchehr Soleimani,et al.  Magnetic induction tomography methods and applications: a review , 2017 .

[21]  Boris Rubinsky,et al.  The detection of brain oedema with frequency-dependent phase shift electromagnetic induction , 2006, Physiological measurement.

[22]  D W Armitage,et al.  Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling , 2009, Physiological measurement.

[23]  H Griffiths,et al.  A primary field compensation scheme for planar array magnetic induction tomography. , 2004, Physiological measurement.

[24]  E. Neufeld,et al.  IT’IS Database for Thermal and Electromagnetic Parameters of Biological Tissues , 2012 .

[25]  Ming Yan,et al.  Imaging hemorrhagic stroke with magnetic induction tomography: realistic simulation and evaluation , 2010, Physiological measurement.

[26]  N. H. Saunders,et al.  A feasibility study of in vivo electromagnetic imaging. , 1993, Physics in medicine and biology.

[27]  Y D Jiang,et al.  Capacitively Coupled Electrical Impedance Tomography for Brain Imaging , 2019, IEEE Transactions on Medical Imaging.

[28]  Wei He,et al.  A multi-channel magnetic induction tomography measurement system for human brain model imaging. , 2009, Physiological measurement.

[29]  Min Han,et al.  Comparison with reconstruction algorithms in magnetic induction tomography , 2016, Physiological measurement.

[30]  Hsin-Yu Wei,et al.  Design of a Sensor Coil and Measurement Electronics for Magnetic Induction Tomography , 2011, IEEE Transactions on Instrumentation and Measurement.

[31]  H Griffiths,et al.  Frequency-difference MIT imaging of cerebral haemorrhage with a hemispherical coil array: numerical modelling. , 2010, Physiological measurement.

[32]  H. Griffiths,et al.  The cardiff Mk2b MIT head array: Optimising the coil configuration , 2010 .

[33]  Xuetao Shi,et al.  Time-difference imaging of magnetic induction tomography in a three-layer brain physical phantom , 2014 .

[34]  Ale Algra,et al.  Incidence, case fatality, and functional outcome of intracerebral haemorrhage over time, according to age, sex, and ethnic origin: a systematic review and meta-analysis , 2010, The Lancet Neurology.

[35]  Hermann Scharfetter,et al.  Magnetic Induction Tomography: A feasibility study of brain oedema detection using a finite element human head model , 2007 .

[36]  H Scharfetter,et al.  Fast calculation of the sensitivity matrix in magnetic induction tomography by tetrahedral edge finite elements and the reciprocity theorem. , 2004, Physiological measurement.

[37]  Wuliang Yin,et al.  A Method to Solve the Forward Problem in Magnetic Induction Tomography Based on the Weakly Coupled Field Approximation , 2010, IEEE Transactions on Biomedical Engineering.

[38]  Ville Kolehmainen,et al.  Electrical Impedance Tomography Problem With Inaccurately Known Boundary and Contact Impedances , 2006, IEEE Transactions on Medical Imaging.

[39]  Hungsun Son,et al.  Magnetic Induction Tomography Using Magnetic Dipole and Lumped Parameter Model , 2019, IEEE Access.

[40]  T. Huisman,et al.  Intracranial hemorrhage: ultrasound, CT and MRI findings , 2005, European Radiology.

[41]  Zhili Xiao,et al.  3-D Hemorrhage Imaging by Cambered Magnetic Induction Tomography , 2019, IEEE Transactions on Instrumentation and Measurement.