Electrical stimulation of isolated retina with microwire glass electrodes

The development of high-resolution retinal prostheses fabricated from silicon wafers presents an interesting problem: how to electrically bridge the space between the flat silicon wafer and the curved retinal surface. One potential "bridge" is a microwire glass electrode. In this paper we present our results in evaluating microwire glass electrodes. We stimulated isolated rabbit retina (n = 5) with a 0.0256 cm(2) microwire electrode. The current and pulse duration were varied from 498 to 1660 microA and 0.1 to 3 ms, respectively. We found that short pulses produced more spikes per coulomb and longer pulses produced more spikes per milliamp. The optimal pulse duration range of 0.7-1 ms was identified as a compromise between the advantages of short and long pulses. Stimulation of isolated rabbit retina with microwire glass results in consistent neuronal spike formation at safe charge density, 20.7 +/- 4.3 microC/cm(2). We also examined the response of retinas (n = 6) to stimulation with a smaller microwire electrode, 0.0002 cm(2). We found that less current was required (15 microA versus 756 microA) for a 1 ms pulse, but at the expense of greater charge density (75 microC/cm(2) versus 29.5 microC/cm(2)). Nonetheless, a 128-fold reduction in area resulted in only a 2.7-fold increase in charge density required for a 1 ms pulse duration. The results presented here indicate that microwire glass can be used as a neural stimulating electrode to bridge the gap between flat microelectronic stimulator chips and curved neuronal tissue.

[1]  E. Zrenner,et al.  Electrical multisite stimulation of the isolated chicken retina , 2000, Vision Research.

[2]  E. Guallar,et al.  Use of two-segmented logistic regression to estimate change-points in epidemiologic studies. , 1998, American journal of epidemiology.

[3]  In Vitro Activation Of Ganglion Cells In Rabbit Retina: Effects Of Glutamate Receptor Agents , 2002 .

[4]  J. Mortimer,et al.  Visual sensations produced by optic nerve stimulation using an implanted self-sizing spiral cuff electrode , 1998, Brain Research.

[5]  W. Liu,et al.  A neuro-stimulus chip with telemetry unit for retinal prosthetic device , 2000, IEEE Journal of Solid-State Circuits.

[6]  J. Weiland,et al.  Pattern electrical stimulation of the human retina , 1999, Vision Research.

[7]  A. Y. Chow,et al.  Implantation of silicon chip microphotodiode arrays into the cat subretinal space , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  D Hickingbotham,et al.  Bipolar surface electrical stimulation of the vertebrate retina. , 1994, Archives of ophthalmology.

[9]  E. Zrenner,et al.  Can subretinal microphotodiodes successfully replace degenerated photoreceptors? , 1999, Vision Research.

[10]  Barry B. Lee,et al.  Single Units and Sensation: A Retrospect , 1999, Perception.

[11]  R. Jensen,et al.  Unexpectedly Small Percepts Evoked by Epi-Retinal Electrical Stimulation in Blind Humans , 2003 .

[12]  J. Weiland,et al.  Intraocular retinal prosthesis test device , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  A. Ames,et al.  In Vitro Retina as an Experimental Model of the Central Nervous System , 1981, Journal of neurochemistry.

[14]  S. Ghaskadbi,et al.  Post‐nodal mesoblast caudalizes the host axis and inhibits cell population growth, and induces new primitive streaks in chick embryos , 2002, Development, growth & differentiation.

[15]  R. Eckmiller Learning retina implants with epiretinal contacts. , 1997, Ophthalmic research.

[16]  W. Grill,et al.  The effect of stimulus pulse duration on selectivity of neural stimulation , 1996, IEEE Transactions on Biomedical Engineering.

[17]  Srinivas R. Sadda,et al.  Electrical Stimulation of Normal and Retinal Degenerate (rd) Isolated Mouse Retina with 25 um Electrodes , 2002 .

[18]  James D. Weiland,et al.  In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes , 2002, IEEE Transactions on Biomedical Engineering.

[19]  J. Wyatt,et al.  REVIEW ■ : Prospects for a Visual Prosthesis , 1997 .

[20]  J. Rizzo,et al.  Multi-electrode stimulation and recording in the isolated retina , 2000, Journal of Neuroscience Methods.

[21]  J. Weiland,et al.  Retinal prosthesis for the blind. , 2002, Survey of ophthalmology.

[22]  V. Deshmukh Logistic Patterning of Brain Activity , 1989, Clinical EEG.

[23]  T.L. Rose,et al.  Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application) , 1990, IEEE Transactions on Biomedical Engineering.

[24]  J. Weiland,et al.  Intraocular retinal prosthesis , 2006, IEEE Engineering in Medicine and Biology Magazine.

[25]  G V Ostir,et al.  Logistic Regression: A Nontechnical Review , 2000, American journal of physical medicine & rehabilitation.

[26]  Gislin Dagnelie,et al.  Understanding the origin of visual percepts elicited by electrical stimulation of the human retina , 1999, Graefe's Archive for Clinical and Experimental Ophthalmology.

[27]  A. Y. Chow,et al.  Subretinal electrical stimulation of the rabbit retina , 1997, Neuroscience Letters.

[28]  Gislin Dagnelie,et al.  Visual perception in a blind subject with a chronic microelectronic retinal prosthesis , 2003, Vision Research.

[29]  R. H. Propst,et al.  Visual perception elicited by electrical stimulation of retina in blind humans. , 1996, Archives of ophthalmology.

[30]  H Bostock,et al.  The strength‐duration relationship for excitation of myelinated nerve: computed dependence on membrane parameters. , 1983, The Journal of physiology.