Prospective motion correction for single‐voxel 1H MR spectroscopy

Head motion during 1H MR spectroscopy acquisitions may compromise the quality and reliability of in vivo metabolite measurements. Therefore, a three‐plane image‐based motion‐tracking module was integrated into a single‐voxel 1H MR spectroscopy (point‐resolved spectroscopy) sequence. A series of three orthogonal spiral navigator images was acquired immediately prior to the MR spectroscopy water suppression module in order to estimate head motion. By applying the appropriate rotations and translations, the MR spectroscopy voxel position can be updated such that it remains stationary with respect to the brain. Frequency and phase corrections were applied during postprocessing to reduce line width and restore coherent averaging. Spectra acquired during intentional head motion in 11 volunteers demonstrate reduced lipid contamination and increased spectral reproducibility when motion correction is applied. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Thomas Ernst,et al.  A novel phase and frequency navigator for proton magnetic resonance spectroscopy using water‐suppression cycling , 2011, Magnetic resonance in medicine.

[2]  Dan Rettmann,et al.  PROMO: Real‐time prospective motion correction in MRI using image‐based tracking , 2010, Magnetic resonance in medicine.

[3]  P K Bhattacharyya,et al.  Spectral quality control in motion‐corrupted single‐voxel J‐difference editing scans: An interleaved navigator approach , 2007, Magnetic resonance in medicine.

[4]  André J W van der Kouwe,et al.  Real‐time rigid body motion correction and shimming using cloverleaf navigators , 2006, Magnetic resonance in medicine.

[5]  Oliver Speck,et al.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system , 2006, NeuroImage.

[6]  G. Elbel,et al.  Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilities , 2002, Magnetic resonance in medicine.

[7]  H E Cline,et al.  Design of a logarithmic k‐space spiral trajectory , 2001, Magnetic resonance in medicine.

[8]  M W Weiner,et al.  Region and tissue differences of metabolites in normally aged brain using multislice 1H magnetic resonance spectroscopic imaging , 2001, Magnetic resonance in medicine.

[9]  C. Jack,et al.  Prospective multiaxial motion correction for fMRI , 2000, Magnetic resonance in medicine.

[10]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[11]  T. Ernst,et al.  Elimination of artifacts in short echo time 1H MR spectroscopy of the frontal lobe , 1996, Magnetic resonance in medicine.

[12]  H. Bruhn,et al.  Localized high‐resolution proton NMR spectroscopy using stimulated echoes: Initial applications to human brain in vivo , 1989, Magnetic resonance in medicine.

[13]  P. Bottomley Spatial Localization in NMR Spectroscopy in Vivo , 1987, Annals of the New York Academy of Sciences.

[14]  Jens Frahm,et al.  Localized proton spectroscopy using stimulated echoes. , 1987 .

[15]  B. Anderson,et al.  Optimal Filtering , 1979 .

[16]  Anders M. Dale,et al.  Motion insensitive 3D imaging using a novel real-time image-based 3D PROspective MOtion correction method (3D PROMO) , 2007 .

[17]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.