Interventional Cardiovascular MRI

Interventional cardiovascular magnetic resonance imaging (iCMR) is potentially revolutionary because of the exquisite tissue and blood imaging afforded to guide therapeutic procedures. By making small compromises in spatial or temporal resolution, and with little or no modifications to commercial high-performance magnetic resonance imaging (MRI) systems, images can be acquired and displayed almost instantaneously to operators. This may be useful simply to avoid ionizing radiation during conventional catheter-based procedures, especially in children. Perhaps more important, iCMR promises to enable more advanced procedures not otherwise possible without open surgical exposure.

[1]  J V Hajnal,et al.  Twisted‐pair RF coil suitable for locating the track of a catheter , 1999, Magnetic resonance in medicine.

[2]  Eugen Hofmann,et al.  Visualization of vascular guidewires using MR tracking , 1998, Journal of magnetic resonance imaging : JMRI.

[3]  Warren J Manning,et al.  Magnetic Resonance–Guided Coronary Artery Stent Placement in a Swine Model , 2002, Circulation.

[4]  F A Jolesz,et al.  Prototype miniature endoluminal MR imaging catheter. , 1993, Journal of vascular and interventional radiology : JVIR.

[5]  David Saloner,et al.  Transendocardial delivery of extracellular myocardial markers by using combination X-ray/MR fluoroscopic guidance: feasibility study in dogs. , 2004, Radiology.

[6]  J. Finn,et al.  Real-Time Magnetic Resonance Imaging-Guided Coronary Catheterization in Swine , 2003, Circulation.

[7]  Ogan Ocali,et al.  Intravascular magnetic resonance imaging using a loopless catheter antenna , 1997, Magnetic resonance in medicine.

[8]  M. Mathier,et al.  Preserved right ventricular ejection fraction predicts exercise capacity and survival in advanced heart failure. , 1995, Journal of the American College of Cardiology.

[9]  J. Badimón,et al.  Real time magnetic resonance guided endomyocardial local delivery , 2005, Heart.

[10]  Ergin Atalar,et al.  Magnetic resonance image‐guided trans‐septal puncture in a swine heart , 2005, Journal of magnetic resonance imaging : JMRI.

[11]  Robert C. Susil,et al.  RF safety of wires in interventional MRI: Using a safety index , 2002 .

[12]  H. K. Charles,et al.  Catheter‐tracking FOV MR fluoroscopy , 1998, Magnetic resonance in medicine.

[13]  T. Schmitz-Rode,et al.  Use of a Nonmetallic Guide Wire for Magnetic Resonance-Guided Coronary Artery Catheterization , 2004, Investigative radiology.

[14]  D. Hill,et al.  Cardiac catheterisation guided by MRI in children and adults with congenital heart disease , 2003, The Lancet.

[15]  Jonathan M Sorger,et al.  Catheter-Based Endomyocardial Injection With Real-Time Magnetic Resonance Imaging , 2002, Circulation.

[16]  Intraarterial contrast material-enhanced magnetic resonance angiography of the aortoiliac system. , 2004, Journal of vascular and interventional radiology : JVIR.

[17]  Jeffrey L Duerk,et al.  Real‐time catheter tracking and adaptive imaging , 2003, Journal of magnetic resonance imaging : JMRI.

[18]  Markus Völk,et al.  Magnetic Resonance-Guided Percutaneous Angioplasty of Femoral and Popliteal Artery Stenoses Using Real-Time Imaging and Intra-arterial Contrast-Enhanced Magnetic Resonance Angiography , 2005, Investigative radiology.

[19]  Alastair J. Martin,et al.  Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: Assessment and validation in a large animal model , 2005, Journal of magnetic resonance imaging : JMRI.

[20]  Cengizhan Ozturk,et al.  Real‐time MRI guided atrial septal puncture and balloon septostomy in swine , 2006, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[21]  Eckart Fleck,et al.  Magnetic Resonance Imaging–Guided Balloon Angioplasty of Coarctation of the Aorta: A Pilot Study , 2006, Circulation.

[22]  Alastair Martin,et al.  Magnetic Resonance–Guided Cardiac Catheterization in a Swine Model of Atrial Septal Defect , 2003, Circulation.

[23]  Daniel Steven,et al.  Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model , 2009, European heart journal.

[24]  Arne Reykowski,et al.  Active device tracking and high‐resolution intravascular MRI using a novel catheter‐based, opposed‐solenoid phased array coil , 2004, Magnetic resonance in medicine.

[25]  G. Laub,et al.  MR‐guided placement of a temporary vena cava filter: Technique and feasibility , 1998, Journal of magnetic resonance imaging : JMRI.

[26]  W. Nitz,et al.  Feasibility of MR-guided Angioplasty of Femoral Artery Stenoses Using Real-time Imaging and Intraarterial Contrast-enhanced MR Angiography , 2004, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[27]  J. Lewin,et al.  MR imaging-guided percutaneous angioplasty and stent placement in a swine model comparison of open- and closed-bore scanners. , 2005, Academic radiology.

[28]  Chris J G Bakker,et al.  Fully MR‐guided hepatic artery catheterization for selective drug delivery: A feasibility study in pigs , 2006, Journal of magnetic resonance imaging : JMRI.

[29]  M A Viergever,et al.  Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventions , 1996, Magnetic resonance in medicine.

[30]  J. Neuerburg,et al.  MR-gesteuerte Spiralembolisation von Nierenarterien in einem Tiermodell , 2003 .

[31]  D B Plewes,et al.  MR imaging of blood vessels with an intravascular coil , 1992, Journal of magnetic resonance imaging : JMRI.

[32]  Elliot R. McVeigh,et al.  Magnetic Resonance Fluoroscopy Allows Targeted Delivery of Mesenchymal Stem Cells to Infarct Borders in Swine , 2003, Circulation.

[33]  E. Wellnhofer,et al.  Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension , 2005, Heart.

[34]  Clemens Bos,et al.  Placement of an inferior vena cava filter in a pig guided by high‐resolution MR fluoroscopy at 1.5 T , 2000, Journal of magnetic resonance imaging : JMRI.

[35]  L. Tavazzi,et al.  Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failure. , 2001, Journal of the American College of Cardiology.

[36]  R Frayne,et al.  MR-guided angioplasty of renal artery stenosis in a pig model: a feasibility study. , 2000, Journal of vascular and interventional radiology : JVIR.

[37]  W. Nitz,et al.  MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. , 2001, Radiology.

[38]  Cengizhan Ozturk,et al.  Real-Time Magnetic Resonance Imaging–Guided Stenting of Aortic Coarctation With Commercially Available Catheter Devices in Swine , 2005, Circulation.

[39]  Richard B. Thompson,et al.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine. , 2005, Journal of the American College of Cardiology.

[40]  R W Günther,et al.  Real-time MR Guidance for inferior vena cava filter placement in an animal model. , 2001, Journal of vascular and interventional radiology : JVIR.

[41]  Peter Boesiger,et al.  Image‐based tracking of optically detunable parallel resonant circuits , 2003, Magnetic resonance in medicine.

[42]  Michael Bock,et al.  Renal Embolization: Feasibility of Magnetic Resonance-Guidance Using Active Catheter Tracking and Intraarterial Magnetic Resonance Angiography , 2004, Investigative radiology.

[43]  Titus Kuehne,et al.  Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. , 2003, Radiology.

[44]  Maggie Fung,et al.  Electroanatomic Mapping of the Left Ventricle in a Porcine Model of Chronic Myocardial Infarction With Magnetic Resonance–Based Catheter Tracking , 2008, Circulation.

[45]  Hugh Calkins,et al.  Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. , 2006, Journal of the American College of Cardiology.

[46]  G. Maddern,et al.  Surgical treatment of atrial fibrillation via energy ablation. , 2005, Circulation.

[47]  Cengizhan Ozturk,et al.  Invasive human magnetic resonance imaging: Feasibility during revascularization in a combined XMR suite , 2005 .

[48]  Charles L Dumoulin,et al.  Transfemoral catheterization of carotid arteries with real-time MR imaging guidance in pigs. , 2005, Radiology.

[49]  R Frayne,et al.  A rapid 2D time‐resolved variable‐rate k‐space sampling MR technique for passive catheter tracking during endovascular procedures , 1998, Magnetic resonance in medicine.

[50]  A. Bücker,et al.  Ein Verfahren zur sicheren Visualisierung und Lokalisierung von Kathetern für MR-geführte intravaskuläre Prozeduren , 2003 .

[51]  R. Balaban,et al.  In Vivo 31P Nuclear Magnetic Resonance Measurements in Canine Heart Using a Catheter‐Coil , 1984, Circulation research.

[52]  P A Bottomley,et al.  High resolution intravascular MRI and MRS by using a catheter receiver coil , 1996, Magnetic resonance in medicine.

[53]  Tobias Schaeffter,et al.  Simultaneous real‐time visualization of the catheter tip and vascular anatomy for MR‐guided PTA of iliac arteries in an animal model , 2002, Journal of magnetic resonance imaging : JMRI.

[54]  Charles L Dumoulin,et al.  Feasibility of stent placement in carotid arteries with real-time MR imaging guidance in pigs. , 2005, Radiology.

[55]  J L Duerk,et al.  Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging , 1992, Magnetic resonance in medicine.

[56]  J S Lewin,et al.  Pulse sequences for interventional magnetic resonance imaging. , 2000, Topics in magnetic resonance imaging : TMRI.

[57]  E. Nagel,et al.  Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: Feasibility study in swine. , 2004, Journal of the American College of Cardiology.

[58]  F. Korosec,et al.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. , 2000, Journal of vascular and interventional radiology : JVIR.

[59]  Simon Wildermuth,et al.  MR-guided percutaneous angioplasty: Assessment of tracking safety, catheter handling and functionality , 2009, CardioVascular and Interventional Radiology.

[60]  Vivek Muthurangu,et al.  Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow , 2004, Circulation.

[61]  Reza Nezafat,et al.  Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study. , 2009, JACC. Cardiovascular imaging.

[62]  H Calkins,et al.  Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. , 2000, Circulation.

[63]  Interventional MRI: Electroanatomical mapping using real-time MR tracking of a deflectable catheter , 2005 .

[64]  M. Ladd,et al.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes , 2000, Magnetic Resonance in Medicine.

[65]  Vivek Muthurangu,et al.  Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization. , 2005, American journal of physiology. Heart and circulatory physiology.

[66]  T Schaeffter,et al.  Real‐time MR fluoroscopy for MR‐guided iliac artery stent placement , 2000, Journal of magnetic resonance imaging : JMRI.

[67]  Mark E Ladd,et al.  Inductively coupled stent antennas in MRI , 2002, Magnetic resonance in medicine.

[68]  Mark E Ladd,et al.  Interventional MRA using actively visualized catheters, TrueFISP, and real‐time image fusion , 2003, Magnetic resonance in medicine.

[69]  V Daanen,et al.  MR‐guided balloon angioplasty of stenosed aorta: In vivo evaluation using near‐standard instruments and a passive tracking technique , 2000, Journal of magnetic resonance imaging : JMRI.

[70]  R. Günther,et al.  MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs. , 2005, Radiology.

[71]  P Boesiger,et al.  Guidewire antennas for MR fluoroscopy , 1997, Magnetic resonance in medicine.

[72]  Robert J. Lederman,et al.  Cardiovascular Interventional MRI , 2005 .

[73]  Rebecca Fahrig,et al.  MR-guided transjugular intrahepatic portosystemic shunt creation with use of a hybrid radiography/MR system. , 2005, Journal of vascular and interventional radiology : JVIR.

[74]  Eugenio Picano,et al.  Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report. , 2009, American heart journal.

[75]  N Chakfé,et al.  Endovascular procedures under near-real-time magnetic resonance imaging guidance: an experimental feasibility study. , 2000, Journal of vascular surgery.

[76]  Michael O Zenge,et al.  Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization , 2005, Magnetic resonance in medicine.

[77]  Ergin Atalar,et al.  Multifunctional interventional devices for MRI: A combined electrophysiology/MRI catheter , 2002, Magnetic resonance in medicine.

[78]  C L Dumoulin,et al.  Intravascular MR tracking catheter: preliminary experimental evaluation. , 1995, AJR. American journal of roentgenology.

[79]  R J Herfkens,et al.  1999 Gary J. Becker Young Investigator Award. MR-guided transjugular portosystemic shunt placement in a swine model. , 1999, Journal of vascular and interventional radiology : JVIR.

[80]  Ergin Atalar,et al.  MRI‐guided coronary catheterization and PTCA: A feasibility study on a dog model , 2003, Magnetic resonance in medicine.

[81]  R. Lederman Cardiovascular Interventional Magnetic Resonance Imaging , 2005, Circulation.

[82]  Cengizhan Ozturk,et al.  Real-Time Magnetic Resonance Imaging–Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model , 2006, Circulation.

[83]  K. Murase,et al.  Primary pulmonary hypertension: 3D dynamic perfusion MRI for quantitative analysis of regional pulmonary perfusion. , 2007, AJR. American journal of roentgenology.

[84]  Daniel F. Kacher,et al.  Characterization of Human Atherosclerotic Plaques by Intravascular Magnetic Resonance Imaging , 2005, Circulation.

[85]  C J Bakker,et al.  Development of an MR‐safe tracking catheter with a laser‐driven tip coil , 2001, Journal of magnetic resonance imaging : JMRI.

[86]  E Atalar,et al.  Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study. , 1998, Journal of vascular and interventional radiology : JVIR.

[87]  C J Bakker,et al.  Passive tracking of catheters and guidewires by contrast‐enhanced MR fluoroscopy , 2001, Magnetic resonance in medicine.

[88]  Ergin Atalar,et al.  Percutaneous MR imaging-guided transvascular access of mesenteric venous system: study in swine model. , 2006, Radiology.

[89]  Michael Jerosch-Herold,et al.  Magnetic Resonance Image-Guided Transcatheter Closure of Atrial Septal Defects , 2003, Circulation.

[90]  E. Atalar,et al.  MR‐trackable intramyocardial injection catheter , 2004, Magnetic resonance in medicine.

[91]  E. McVeigh,et al.  Interventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderings , 2007, Journal of magnetic resonance imaging : JMRI.

[92]  Bernd Hamm,et al.  A Vascular Stent as an Active Component for Locally Enhanced Magnetic Resonance Imaging: Initial In Vivo Imaging Results After Catheter-guided Placement in Rabbits , 2003, Investigative radiology.

[93]  Vivek Muthurangu,et al.  Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients , 2004, Magnetic resonance in medicine.

[94]  Bob S. Hu,et al.  In vivo real-time intravascular MRI. , 2002, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[95]  Rebecca Fahrig,et al.  Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations , 2003, Journal of magnetic resonance imaging : JMRI.

[96]  Ergin Atalar,et al.  Intravascular extended sensitivity (IVES) MRI antennas , 2003, Magnetic resonance in medicine.

[97]  David S. Lee,et al.  Human peripheral arteries: feasibility of transvenous intravascular MR imaging of the arterial wall. , 2005, Radiology.

[98]  Meir Shinnar,et al.  A Novel Nonobstructive Intravascular MRI Coil: In Vivo Imaging of Experimental Atherosclerosis , 2003, Arteriosclerosis, thrombosis, and vascular biology.

[99]  Cengizhan Ozturk,et al.  Active two‐channel 0.035″ guidewire for interventional cardiovascular MRI , 2009, Journal of magnetic resonance imaging : JMRI.

[100]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[101]  Tobias Schaeffter,et al.  Magnetic Resonance–Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale , 2002, Circulation.

[102]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[103]  J S Lewin,et al.  An optical system for wireless detuning of parallel resonant circuits. , 2000, Journal of magnetic resonance imaging : JMRI.