An adaptive current tomograph using voltage sources

An adaptive electric current tomography system that contains a novel front-end analog architecture was developed. Programmable voltage sources were used to deliver currents into the study object and to avoid the difficulties of obtaining high-quality current sources. Through inverting an admittance matrix, the system is capable of achieving a desired current drive pattern by applying a computed voltage pattern. The tomograph, operating at 9.6 kHz, comprises 32 driving electrodes and 32 voltage measurement electrodes. The study of system noise performance shows high SNR in the data acquisition which is enhanced by a digital demodulation scheme. In vitro reconstruction images have been obtained with the data collected by the tomograph.<<ETX>>

[1]  Paul Horowitz,et al.  The Art of Electronics - 2nd Edition , 1989 .

[2]  W. R. Bennett,et al.  Spectra of quantized signals , 1948, Bell Syst. Tech. J..

[3]  J. C. Goble,et al.  Current Sources For Impedance Imaging Systems , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  M. Pidcock,et al.  A hybrid phantom for electrical impedance tomography. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[5]  B H Brown,et al.  Applied potential tomography: a new non-invasive technique for assessing gastric function. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[6]  Brian H. Brown,et al.  Digital demodulator for electrical impedance imaging , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[7]  J.C. Newell,et al.  An electric current tomograph , 1988, IEEE Transactions on Biomedical Engineering.

[8]  J. C. Goble,et al.  A Phase Sensitive Voltmeter For A High-speed, High-precision Electrical Impedance Tomograph , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[9]  Michael Pidcock,et al.  Ill-Posedness and Non-Linearity in Electrical Impedance Tomography , 1988 .

[10]  D. C. Barber Electrical impedance tomography/applied potential tomography , 1993 .

[11]  D. Isaacson Distinguishability of Conductivities by Electric Current Computed Tomography , 1986, IEEE Transactions on Medical Imaging.

[12]  G.J. Saulnier,et al.  ACT3: a high-speed, high-precision electrical impedance tomograph , 1991, IEEE Transactions on Biomedical Engineering.

[13]  H W Woo,et al.  A prototype system and reconstruction algorithms for electrical impedance technique in medical body imaging. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[14]  B. Brown,et al.  Applied potential tomography. , 1989, Journal of the British Interplanetary Society.

[15]  B H Brown,et al.  The Sheffield data collection system. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.