Performance of Wood Shear Walls Sheathed with FRP-Reinforced OSB Panels

This study addresses the development and structural testing of a hybrid sheathing panel designed to improve the lateral resistance of light wood-frame shear walls. The panel consists of thin outer sheets of oriented-strand board (OSB) bonded to strips of fiber-reinforced polymer (FRP) that are sandwiched between the OSB panels at the edges. The FRP-reinforced panel material selection and fabrication are summarized. Monotonic and cyclic tests were conducted to assess the performance of single-connector sheathing-to-framing connections using both OSB and FRP-reinforced OSB. Twenty-four full-scale shear walls were tested under monotonic and cyclic racking loads to determine the benefits of FRP-reinforced OSB to wall lateral load resistance. For a 102 mm perimeter nail spacing, FRP-reinforced OSB-sheathed walls exhibited increases in peak capacity and energy dissipation under cyclic loading of 27 and 73%, respectively, compared to walls sheathed with conventional OSB. Based on these experimental results, FRP-reinforced OSB panels appear to have significant potential for increasing the energy dissipation capacity and lateral load resistance of wood-frame structures subjected to extreme lateral loads. However, their full utilization will require higher strengths for critical shear wall components such as tension ties and framing interconnections, as well as improvements in sheathing-to-framing fastener performance.

[1]  Roger Frost,et al.  International Organization for Standardization (ISO) , 2004 .

[2]  Frank Lam,et al.  Cyclic Performance of Perforated Wood Shear Walls with Oversize OSB Panels , 1999 .

[3]  J. Daniel Dolan,et al.  The racking performance of shear walls with various aspect ratios. Part I. Monotonic tests of fully anchored walls , 2003 .

[4]  Frank Lam,et al.  Seismic Resistance of Wood Shear Walls with Large OSB Panels , 2001 .

[5]  Lawrence A. Soltis,et al.  Fiberglass-reinforced bolted wood connections , 1998 .

[6]  Frank Lam,et al.  Lateral Resistance of Wood Shear Walls with Large Sheathing Panels , 1997 .

[7]  J. D. Dolan,et al.  Monotonie and cyclic tests of timber shear walls , 1992 .

[8]  Guk-Rwang Won American Society for Testing and Materials , 1987 .

[9]  Jeffrey D. Langlois Effects of reference displacement and damage accumulation in wood shear walls subjected to the CUREE protocol , 2002 .

[10]  Eric Dana Cassidy Development and Structural Testing of FRP Reinforced OSB Panels for Disaster Resistant Construction , 2002 .

[11]  F. Fonseca,et al.  Strength and Behavior of Hybrid Diaphragms , 2002 .

[12]  Y. Chui,et al.  Load-Embedment Response of Timber to Reversed Cyclic Load , 2007 .

[13]  Fernando Fonseca,et al.  Capacity of Oriented Strand Board Shear Walls with Overdriven Sheathing Nails , 2002 .

[14]  Harry W. Shenton,et al.  COMPARISON OF STATIC AND DYNAMIC RESPONSE OF TIMBER SHEAR WALLS , 1998 .

[15]  J. D. Dolan Reply: Monotonic and cyclic tests of timber shear walls , 1992 .