Unusual presence of ‘ghosts’ following lead extraction for recurrent reactive pericarditis: a case report

Abstract Background The presence of a persistent fibrous sheath in right-sided heart chambers after transvenous lead extraction has already been described in some studies as echocardiographic tubular mobile masses called ‘ghosts’. Their presence has been associated with cardiac device-related infective endocarditis or local device infection, but to the best of our knowledge, this is the first case where ‘ghosts’ have been reported among non-infected patients. Case summary We present a case of a 73-year-old woman hospitalized due to worsening dyspnoea and a significant pericardial effusion, relapsed after pericardiocentesis with removal of about 1500 mL of non-haemorrhagic fluid. The patient’s history revealed a previous dual-chamber pacemaker implantation due to symptomatic sick sinus syndrome. Transoesophageal echocardiography (TOE), essential to exclude endocarditis vegetations suggested an etiopathogenesis of mechanical irritation caused by the distal end of the passive fixation atrial lead on the right atrial appendage wall. Considering the echocardiographic report and the condition of reactive pericarditis with the early relapse of the significant pericardial effusion after pericardiocentesis, we opted for a lead removal procedure to eliminate the stimulus causing the irritation, with transoesophageal echocardiographic monitoring, thus the early detection of a ‘ghost’ was possible. Discussion This is the first clinical case describing the presence of fibrin ‘ghosts’ sometime after the implantation of a pacemaker, highlighting a non-exclusively infectious genesis, and emphasizing the importance of TOE for the early detection of this post-extraction complication and its monitoring.

[1]  M. Shoda,et al.  2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. , 2017, Heart rhythm.

[2]  A. Rebuzzi,et al.  Presence of ‘ghosts’ and mortality after transvenous lead extraction , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[3]  J. Geller,et al.  Incidence and Predictors of Pericardial Effusion After Permanent Heart Rhythm Device Implantation , 2013 .

[4]  D. Raoult,et al.  Diagnosis of cardiac device-related infective endocarditis after device removal. , 2010, JACC. Cardiovascular imaging.

[5]  A. Dello Russo,et al.  Residual fibrous tissue floating in the right atrium after percutaneous pacemaker lead extraction: an unusual complication early detected by intracardiac echocardiography. , 2008, International journal of cardiology.

[6]  M. Eldar,et al.  Pericarditis following permanent pacemaker insertion. , 2004, The Israel Medical Association journal : IMAJ.