Parametric Imaging With PET and SPECT

In molecular imaging modalities such as positron emission tomography (PET) or single photon emission computed tomography (SPECT), parametric imaging is the process of creating fully quantitative 3-D maps of pharmacokinetic parameters from a dynamic series of radiotracer concentration images. An overview of the pharmacokinetic parameters that have been assessed in PET or SPECT studies, and the kinetic models that have been proposed to compute parametric images is presented. Parametric imaging is challenging due to the high level of noise in the raw images obtained from the scanner, and the additional needs to obtain the input function of the kinetic model and to correct for subject motion during the usually long dynamic scans. Methods that have been proposed to assess each of these challenges are been reviewed.

[1]  C. J. Thompson,et al.  Motion correction of PET images using multiple acquisition frames , 1997, IEEE Transactions on Medical Imaging.

[2]  Brian F. Hutton,et al.  Sign determination methods for the respiratory signal in data-driven PET gating , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[3]  Matthias Stuber,et al.  Self-Navigation with Compressed Sensing for 2D Translational Motion Correction in Free-Breathing Coronary MRI: A Feasibility Study , 2014, PloS one.

[4]  V J Cunningham,et al.  Compartmental Analysis of Diprenorphine Binding to Opiate Receptors in the Rat in vivo and its Comparison with Equilibrium Data in vitro , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[5]  Tobias Schaeffter,et al.  Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR , 2017, The Journal of Nuclear Medicine.

[6]  Bernard Bendriem,et al.  Modeling Analysis of [11C]Flumazenil Kinetics Studied by PET: Application to a Critical Study of the Equilibrium Approaches , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[7]  Ronald Boellaard,et al.  Evaluation of Basis Function and Linear Least Squares Methods for Generating Parametric Blood Flow Images Using 15O-Water and Positron Emission Tomography , 2005, Molecular Imaging and Biology.

[8]  Guobao Wang,et al.  Dynamic PET Image reconstruction for parametric imaging using the HYPR kernel method , 2017, Medical Imaging.

[9]  Sverre Myhra,et al.  Chemically amplified photoresist as a medium for quantitative 3-D high spatial resolution autoradiography , 2011 .

[10]  C. Tsoumpas,et al.  Convergence properties of algorithms for direct parametric estimation of linear models in dynamic PET , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[11]  Anthony P. Reeves,et al.  Automated aorta segmentation in low-dose chest CT images , 2014, International Journal of Computer Assisted Radiology and Surgery.

[12]  Guobao Wang,et al.  Acceleration of the direct reconstruction of linear parametric images using nested algorithms , 2010, Physics in medicine and biology.

[13]  Roger Fulton,et al.  Correction for head movements in positron emission tomography using an optical motion tracking system , 2000 .

[14]  James V. Beck,et al.  Parameter Estimation in Engineering and Science , 1977 .

[15]  Xiao Jin,et al.  Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution , 2017, Physics in medicine and biology.

[16]  P. Marsden,et al.  Retrospective data-driven respiratory gating for PET/CT , 2008, Physics in medicine and biology.

[17]  Claudio Cobelli,et al.  Tracer Kinetics in Biomedical Research: From Data to Model , 2013 .

[18]  M. Phelps,et al.  Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Jeffrey A Fessler,et al.  Improving PET Receptor Binding Estimates from Logan Plots Using Principal Component Analysis , 2008, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[20]  Roger Fulton,et al.  A scheme for PET data normalization in event-based motion correction , 2009, Physics in medicine and biology.

[21]  Charles A Mistretta,et al.  Dynamic PET Denoising with HYPR Processing , 2010, Journal of Nuclear Medicine.

[22]  Darrell Burckhardt,et al.  Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET. , 2016, Radiology.

[23]  Roger N Gunn,et al.  Positron Emission Tomography Compartmental Models: A Basis Pursuit Strategy for Kinetic Modeling , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[24]  Iwao Kanno,et al.  Measurement of Cerebral Blood Flow Using Bolus Inhalation of C15O2 and Positron Emission Tomography: Description of the Method and its Comparison with the C15O2 Continuous Inhalation Method , 1984, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[25]  Fang Yuan,et al.  A general method of Bayesian estimation for parametric imaging of the brain , 2008, NeuroImage.

[26]  R. Huesman,et al.  Fine-scale motion detection using intrinsic list mode PET information , 2001, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 2001).

[27]  Jerry L. Prince,et al.  Motion estimation from tagged MR image sequences , 1992, IEEE Trans. Medical Imaging.

[28]  Alexander Hammers,et al.  Multi-Scale hierarchical generation of PET parametric maps: Application and testing on a [11C]DPN study , 2010, NeuroImage.

[29]  Georgios I. Angelis,et al.  Impact of erroneous kinetic model formulation in Direct 4D image reconstruction , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[30]  N. Sadato,et al.  Noninvasive measurement of cerebral metabolic rate of glucose using standardized input function. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[31]  Kris Thielemans,et al.  Quiescent period respiratory gating for PET/CT. , 2010, Medical physics.

[32]  R. P. Maguire,et al.  Consensus Nomenclature for in vivo Imaging of Reversibly Binding Radioligands , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[33]  Václav Smídl,et al.  Bayesian Blind Separation and Deconvolution of Dynamic Image Sequences Using Sparsity Priors , 2015, IEEE Transactions on Medical Imaging.

[34]  Ashley Gillman,et al.  PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections , 2017, Medical physics.

[35]  R. deKemp,et al.  Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging. , 2016, Medical physics.

[36]  Bruce R. Rosen,et al.  A regularized full reference tissue model for PET neuroreceptor mapping , 2016, NeuroImage.

[37]  A. Lammertsma,et al.  Simplified Reference Tissue Model for PET Receptor Studies , 1996, NeuroImage.

[38]  Zhaoying Bian,et al.  Dynamic Positron Emission Tomography Image Restoration via a Kinetics-Induced Bilateral Filter , 2014, PloS one.

[39]  B. Lopresti,et al.  Implementation and performance of an optical motion tracking system for high resolution brain PET imaging , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[40]  Stefan Eberl,et al.  Evaluation of two population-based input functions for quantitative neurological FDG PET studies , 1997, European Journal of Nuclear Medicine.

[41]  L. Wahl,et al.  Equilibration of 6-[18F]fluoro-L-m-tyrosine between plasma and erythrocytes. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[42]  S. Gunn,et al.  Positron Emission Tomography Compartmental Models , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[43]  Ming-Rong Zhang,et al.  PET Quantification of Tau Pathology in Human Brain with 11C-PBB3 , 2015, The Journal of Nuclear Medicine.

[44]  Jieqing Jiao,et al.  Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET Data , 2017, IEEE Trans. Medical Imaging.

[45]  Nassir Navab,et al.  Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data , 2015, IEEE Transactions on Medical Imaging.

[46]  A. Lammertsma Quantification of Cerebral Blood Flow , 2012 .

[47]  Karmen K. Yoder,et al.  ntPET: a new application of PET imaging for characterizing the kinetics of endogenous neurotransmitter release. , 2005, Molecular imaging.

[48]  E. Hoffman,et al.  TOMOGRAPHIC MEASUREMENT OF LOCAL CEREBRAL GLUCOSE METABOLIC RATE IN HUMANS WITH (F‐18)2‐FLUORO-2‐DEOXY-D‐GLUCOSE: VALIDATION OF METHOD , 1980, Annals of neurology.

[49]  Alexander Hammers,et al.  Global-two-stage filtering of clinical PET parametric maps: Application to [11C]-(R)-PK11195 , 2011, NeuroImage.

[50]  Denis Guilloteau,et al.  Kinetic Analysis and Quantification of the Dopamine Transporter in the Nonhuman Primate Brain with 11C-PE2I and 18F-FE-PE2I , 2011, The Journal of Nuclear Medicine.

[51]  Marc Laruelle,et al.  A new positron emission tomography imaging agent for the serotonin transporter: synthesis, pharmacological characterization, and kinetic analysis of [11C]2-[2-(dimethylaminomethyl)phenylthio]-5-fluoromethylphenylamine ([11C]AFM). , 2004, Nuclear medicine and biology.

[52]  H. Zaidi,et al.  Impact of motion on indirect and direct reconstruction of kinetic parameters from dynamic PET data , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[53]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[54]  M. Ozaki,et al.  Evaluation of liver tumors using fluorine-18-fluorodeoxyglucose PET: characterization of tumor and assessment of effect of treatment. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[55]  C Tsoumpas,et al.  Analysis and comparison of two methods for motion correction in PET imaging. , 2012, Medical physics.

[56]  Cyrill Burger,et al.  Respiration-induced attenuation artifact at PET/CT: technical considerations. , 2003, Radiology.

[57]  T. Jones,et al.  Spectral Analysis of Dynamic PET Studies , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[58]  J. Jacquez Compartmental analysis in biology and medicine: Kinetics of distribution of tracer-labeled materials , 1972 .

[59]  Peter Herscovitch,et al.  Comparison of Bolus and Infusion Methods for Receptor Quantitation: Application to [18F]Cyclofoxy and Positron Emission Tomography , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[60]  Georgios I. Angelis,et al.  Adaptive parametric kinetic modelling for improved full field of view fitting of PET data , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[61]  Yun Zhou,et al.  Clustering-Based Linear Least Square Fitting Method for Generation of Parametric Images in Dynamic FDG PET Studies , 2007, Int. J. Biomed. Imaging.

[62]  Richard E Carson,et al.  Noise Reduction in the Simplified Reference Tissue Model for Neuroreceptor Functional Imaging , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[63]  B. Rosen,et al.  Functional Characterization of 5-HT1B Receptor Drugs in Nonhuman Primates Using Simultaneous PET-MR , 2017, The Journal of Neuroscience.

[64]  Thomas Beyer,et al.  On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[65]  R. Carson,et al.  PET physiological measurements using constant infusion. , 2000, Nuclear medicine and biology.

[66]  T Schaeffter,et al.  Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator , 2012, Medical Image Anal..

[67]  D. Bailey,et al.  The direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction. , 1997 .

[68]  Kewei Chen,et al.  Image-Derived Input Function for Brain PET Studies: Many Challenges and Few Opportunities , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[69]  Loïc Fin,et al.  Motion correction based on an appropriate system matrix for statistical reconstruction of respiratory-correlated PET acquisitions , 2009, Comput. Methods Programs Biomed..

[70]  Anthonin Reilhac,et al.  Optimization of dynamic measurement of receptor kinetics by wavelet denoising , 2006, NeuroImage.

[71]  C S Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data , 1983, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[72]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[73]  Randy L. Gollub,et al.  Simultaneous fMRI–PET of the opioidergic pain system in human brain , 2014, NeuroImage.

[74]  Paul E Kinahan,et al.  The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging , 2009, Physics in medicine and biology.

[75]  El Mostafa Fadaili,et al.  Comparison of Eight Methods for the Estimation of the Image-Derived Input Function in Dynamic [18F]-FDG PET Human Brain Studies , 2009, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[76]  C. Comtat,et al.  Fully 4D image reconstruction by estimation of an input function and spectral coefficients , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[77]  Guobao Wang,et al.  Direct Estimation of Kinetic Parametric Images for Dynamic PET , 2013, Theranostics.

[78]  Michael A. King,et al.  Quantitative Study of Rigid-Body and Respiratory Motion of Patients Undergoing Stress and Rest Cardiac SPECT Imaging , 2008, IEEE Transactions on Nuclear Science.

[79]  Georges El Fakhri,et al.  Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[80]  Claudio Cobelli,et al.  Carbohydrate metabolism: Quantitative physiology and mathematical modelling , 1981 .

[81]  Urs E. Ruttimann,et al.  Head motion during positron emission tomography: is it significant? , 1995, Psychiatry Research: Neuroimaging.

[82]  A. Rahmim,et al.  Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach , 2004, IEEE Transactions on Nuclear Science.

[83]  Jim O'Doherty,et al.  Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET , 2015, Nuclear medicine communications.

[84]  Y Yonekura,et al.  In vivo assessment of glucose metabolism in hepatocellular carcinoma with FDG-PET. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[85]  R. Parsey,et al.  Simultaneous Estimation of Input Functions: An Empirical Study , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[86]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[87]  Tim Mulnix,et al.  Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET , 2019, Physics in medicine and biology.

[88]  Arun Krishnan,et al.  Robust Learning-Based Parsing and Annotation of Medical Radiographs , 2011, IEEE Transactions on Medical Imaging.

[89]  Jeih-San Liow,et al.  Linearized Reference Tissue Parametric Imaging Methods: Application to [11C]DASB Positron Emission Tomography Studies of the Serotonin Transporter in Human Brain , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[90]  Kevin M. Johnson,et al.  Improved waveform fidelity using local HYPR reconstruction (HYPR LR) , 2008, Magnetic resonance in medicine.

[91]  Guobao Wang,et al.  An Optimization Transfer Algorithm for Nonlinear Parametric Image Reconstruction From Dynamic PET Data , 2012, IEEE Transactions on Medical Imaging.

[92]  Florian Büther,et al.  On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework , 2014, EJNMMI Physics.

[93]  Ciprian Catana,et al.  Imaging Agonist-Induced D2/D3 Receptor Desensitization and Internalization In Vivo with PET/fMRI , 2016, Neuropsychopharmacology.

[94]  C Burger,et al.  Kinetic and equilibrium analyses of [(123)I]epidepride binding to striatal and extrastriatal dopamine D(2) receptors. , 1999, Synapse.

[95]  L Cinotti,et al.  Parameter and index images of benzodiazepine receptor concentration in the brain. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[96]  Robert B. Innis,et al.  Strategies to Improve Neuroreceptor Parameter Estimation by Linear Regression Analysis , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[97]  James Hamill,et al.  Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[98]  R. Huesman,et al.  Non-rigid summing of gated PET via optical flow , 1996 .

[99]  David J. Schlyer,et al.  Graphical Analysis of Reversible Radioligand Binding from Time—Activity Measurements Applied to [N-11C-Methyl]-(−)-Cocaine PET Studies in Human Subjects , 1990, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[100]  Ciprian Catana,et al.  Neurovascular coupling to D2/D3 dopamine receptor occupancy using simultaneous PET/functional MRI , 2013, Proceedings of the National Academy of Sciences.

[101]  Ramin V. Parsey,et al.  Determination of Volume of Distribution using Likelihood Estimation in Graphical Analysis: Elimination of Estimation Bias , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[102]  G. Sedvall,et al.  Quantitative analysis of D2 dopamine receptor binding in the living human brain by PET. , 1986, Science.

[103]  M Slifstein,et al.  Effects of statistical noise on graphic analysis of PET neuroreceptor studies. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[104]  Ioannis A. Kakadiaris,et al.  Segmentation of the Thoracic Aorta in Noncontrast Cardiac CT Images , 2013, IEEE Journal of Biomedical and Health Informatics.

[105]  Yiyun Huang,et al.  Parametric Imaging and Test–Retest Variability of 11C-(+)-PHNO Binding to D2/D3 Dopamine Receptors in Humans on the High-Resolution Research Tomograph PET Scanner , 2014, The Journal of Nuclear Medicine.

[106]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[107]  Yuji Nakamoto,et al.  PET/CT: artifacts caused by bowel motion , 2004, Nuclear medicine communications.

[108]  N. Volkow,et al.  Distribution Volume Ratios without Blood Sampling from Graphical Analysis of PET Data , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[109]  Kris Thielemans,et al.  Motion compensated image reconstruction of respiratory gated PET/CT , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[110]  Xiaoyi Jiang,et al.  A Dynamic Thorax Phantom for the Assessment of Cardiac and Respiratory Motion Correction in PET/MRI: A Preliminary Evaluation. , 2013 .

[111]  S. Hesse,et al.  News and views on in-vivo imaging of neurotransmission using PET and MRI. , 2017, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[112]  Kris Thielemans,et al.  Correction of head movement on PET studies: comparison of methods. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[113]  C Crouzel,et al.  Cardiac beta-adrenergic receptor density measured in vivo using PET, CGP 12177, and a new graphical method. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[114]  Ken D. Sauer,et al.  Direct reconstruction of kinetic parameter images from dynamic PET data , 2005, IEEE Transactions on Medical Imaging.

[115]  Alessandra Bertoldo,et al.  Plasma radiometabolite correction in dynamic PET studies: Insights on the available modeling approaches , 2016, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[116]  Richard E. Carson,et al.  Cardiac‐gated parametric images from 82Rb PET from dynamic frames and direct 4D reconstruction , 2018, Medical physics.

[117]  D. Visvikis,et al.  Respiratory motion in positron emission tomography for oncology applications: Problems and solutions , 2006 .

[118]  F E Turkheimer,et al.  Modeling Dynamic PET-SPECT Studies in the Wavelet Domain , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[119]  R. Myers,et al.  Quantitation of Carbon‐11‐labeled raclopride in rat striatum using positron emission tomography , 1992, Synapse.

[120]  M. Phelps,et al.  Parametric images of myocardial metabolic rate of glucose generated from dynamic cardiac PET and 2-[18F]fluoro-2-deoxy-d-glucose studies. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[121]  Mikko Sams,et al.  Dissociable Roles of Cerebral &mgr;-Opioid and Type 2 Dopamine Receptors in Vicarious Pain: A Combined PET–fMRI Study , 2017, Cerebral cortex.

[122]  Tim Mulnix,et al.  Investigation of Sub-Centimeter Lung Nodule Quantification for Low-Dose PET , 2018, IEEE Transactions on Radiation and Plasma Medical Sciences.

[123]  Kris Thielemans,et al.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography. , 2008, Medical physics.

[124]  Dean F. Wong,et al.  Accurate Event-Driven Motion Compensation in High-Resolution PET Incorporating Scattered and Random Events , 2008, IEEE Transactions on Medical Imaging.

[125]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[126]  W. O'Dell,et al.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. , 1995, Radiology.

[127]  Richard E Carson,et al.  Measurement of Bmax and Kd with the Glycine Transporter 1 Radiotracer 18F-MK6577 using a Novel Multi-Infusion Paradigm , 2015, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[128]  Cyril Riddell,et al.  A linear wavelet filter for parametric imaging with dynamic PET , 2003, IEEE Transactions on Medical Imaging.

[129]  Alexander Hammers,et al.  Multi-scale hierarchical generation of PET parametric maps: Application and testing on [11C]DPN study , 2010, NeuroImage.

[130]  C. Ling,et al.  Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[131]  M'hamed Bentourkia,et al.  Kinetic modeling of PET-FDG in the brain without blood sampling , 2006, Comput. Medical Imaging Graph..

[132]  A human PET study of [11C]HMS011, a potential radioligand for AMPA receptors , 2017, EJNMMI Research.

[133]  Ronald Boellaard,et al.  Optimization algorithms and weighting factors for analysis of dynamic PET studies , 2006, Physics in medicine and biology.

[134]  Michael E. Phelps,et al.  The C15O2 Build-up Technique to Measure Regional Cerebral Blood Flow and Volume of Distribution of Water , 1989, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[135]  Charles A Mistretta,et al.  Improved kinetic analysis of dynamic PET data with optimized HYPR-LR. , 2012, Medical physics.

[136]  José Guimón,et al.  Wavelet Analysis of Dynamic PET Data: Application to the Parametric Imaging of Benzodiazepine Receptor Concentration , 2000, NeuroImage.

[137]  M. Faddy,et al.  Compartmental Analysis in Biology and Medicine, 2nd edition. , 1987 .

[138]  M. Mintun,et al.  A quantitative model for the in vivo assessment of drug binding sites with positron emission tomography , 1984, Annals of neurology.

[139]  E. Hoffman,et al.  Cardiac Emission Computed Tomography: Underestimation of Regional Tracer Concentrations Due to Wall Motion Abnormalities , 1984, Journal of computer assisted tomography.

[140]  R A Koeppe,et al.  Performance Comparison of Parameter Estimation Techniques for the Quantitation of Local Cerebral Blood Flow by Dynamic Positron Computed Tomography , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[141]  R. Boellaard,et al.  Quantification of 11C-Laniquidar Kinetics in the Brain , 2015, The Journal of Nuclear Medicine.

[142]  S. Mustafovic,et al.  Normalisation of Histogrammed List Mode Data , 2008, IEEE Transactions on Nuclear Science.

[143]  Jieqing Jiao,et al.  Impact of image-based motion correction on dopamine D3/D2 receptor occupancy—comparison of groupwise and frame-by-frame registration approaches , 2015, EJNMMI Physics.

[144]  N. Alpert,et al.  Comparison of Two Compartmental Models for Describing Receptor Ligand Kinetics and Receptor Availability in Multiple Injection PET Studies , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[145]  F. O'Sullivan,et al.  An adaptation of ridge regression for improved estimation of kinetic model parameters from PET studies , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[146]  Ulas Bagci,et al.  A review on segmentation of positron emission tomography images , 2014, Comput. Biol. Medicine.

[147]  G Malandain,et al.  Model-based respiratory motion compensation for emission tomography image reconstruction , 2007, Physics in medicine and biology.

[148]  Jing Tang,et al.  4D respiratory motion-corrected Rb-82 myocardial perfusion PET image reconstruction , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[149]  David A Lynch,et al.  Data‐driven optimal binning for respiratory motion management in PET , 2018, Medical physics.

[150]  Xiaoyi Jiang,et al.  Lung motion correction on respiratory gated 3-D PET/CT images , 2006, IEEE Transactions on Medical Imaging.

[151]  I. Buvat,et al.  A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology , 2012, Physics in medicine and biology.

[152]  R. Frackowiak,et al.  Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission Tomography: Theory, Procedure, and Normal Values , 1980, Journal of computer assisted tomography.

[153]  Mark Lubberink,et al.  Off-line motion correction methods for multi-frame PET data , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[154]  Lutz Tellmann,et al.  Motion artifact reduction on parametric PET images of neuroreceptor binding. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[155]  Philippe Millet,et al.  Quantification of dopamine D2/3 receptors in rat brain using factor analysis corrected [18F]Fallypride images , 2012, NeuroImage.

[156]  Sung-Cheng Huang,et al.  Linear regression with spatial constraint to generate parametric images of ligand-receptor dynamic PET studies with a simplified reference tissue model , 2003, NeuroImage.

[157]  Bruce R. Rosen,et al.  Cortical surface-based analysis reduces bias and variance in kinetic modeling of brain PET data , 2014, NeuroImage.

[158]  Yiyun Huang,et al.  Binding to D 2 /D 3 Dopamine Receptors in Humans on the High-Resolution Research Tomograph PET Scanner , 2014 .

[159]  Eric P. Visser,et al.  A Curve-Fitting Approach to Estimate the Arterial Plasma Input Function for the Assessment of Glucose Metabolic Rate and Response to Treatment , 2009, Journal of Nuclear Medicine.

[160]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[161]  C. Nahmias,et al.  Dopamine visualized in the basal ganglia of living man , 1983, Nature.

[162]  Yi Su,et al.  The application of maximum likelihood factor analysis (MLFA) with uniqueness constraints on dynamic cardiac microPET data. , 2007, Physics in medicine and biology.

[163]  Sibylle I Ziegler,et al.  Advances in PET/MR instrumentation and image reconstruction. , 2018, The British journal of radiology.

[164]  P. Herrero,et al.  Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model. , 1990, Circulation.

[165]  Georges El Fakhri,et al.  Parametric imaging with Bayesian priors: A validation study with 11C-Altropane PET , 2012, NeuroImage.

[166]  R. Fulton,et al.  Accuracy of motion correction methods for PET brain imaging , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[167]  T. Greitz,et al.  Head fixation device for reproducible position alignment in transmission CT and positron emission tomography. , 1981, Journal of computer assisted tomography.

[168]  J. Delforge,et al.  Identifiability analysis and parameter identification of an in vivo ligand-receptor model from PET data , 1990, IEEE Transactions on Biomedical Engineering.

[169]  S. Nehmeh,et al.  Respiratory motion in positron emission tomography/computed tomography: a review. , 2008, Seminars in nuclear medicine.

[170]  Vincent J Cunningham,et al.  In vivo metabolism and partitioning of 6-[18F]fluoro-L-meta-tyrosine in whole blood: a unified compartment model. , 2002, Physics in medicine and biology.

[171]  James S. Duncan,et al.  Segmentation of the Left Ventricle From Cardiac MR Images Using a Subject-Specific Dynamical Model , 2010, IEEE Transactions on Medical Imaging.

[172]  Paul J Schleyer,et al.  Extension of a data-driven gating technique to 3D, whole body PET studies , 2011, Physics in medicine and biology.

[173]  Michael Brady,et al.  Regularized B-spline deformable registration for respiratory motion correction in PET images , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[174]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[175]  Yun Zhou,et al.  A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies , 2009, NeuroImage.

[176]  Richard E Carson,et al.  Direct EM reconstruction of parametric images from list-mode brain PET using a novel model based on logan graphical analysis , 2016, 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD).

[177]  Jesper L. R. Andersson,et al.  How to obtain high-accuracy image registration: application to movement correction of dynamic positron emission tomography data , 1998, European Journal of Nuclear Medicine.

[178]  Scott E Kasner,et al.  Carotid Artery Diameter in Men and Women and the Relation to Body and Neck Size , 2006, Stroke.

[179]  E. Meyer Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[180]  Vincent J. Cunningham,et al.  Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region Model , 1997, NeuroImage.

[181]  E. M. Renkin Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. , 1959, The American journal of physiology.

[182]  R. Fulton,et al.  Event-by-event motion compensation in 3D PET , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[183]  Uwe Just,et al.  An accurate method for correction of head movement in PET , 2004, IEEE Transactions on Medical Imaging.

[184]  B E Sobel,et al.  Influence of Cardiac and Respiratory Motion on Tomographic Reconstructions of the Heart: Implications for Quantitative Nuclear Cardiology , 1982, Journal of computer assisted tomography.

[185]  R Todd Ogden,et al.  Estimation of kinetic parameters in graphical analysis of PET imaging data , 2003, Statistics in medicine.

[186]  Chung Chan,et al.  Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET , 2018, IEEE Transactions on Medical Imaging.

[187]  Richard E. Carson,et al.  Direct 4-D PET List Mode Parametric Reconstruction With a Novel EM Algorithm , 2012, IEEE Transactions on Medical Imaging.

[188]  Ciprian Catana,et al.  Motion correction options in PET/MRI. , 2015, Seminars in nuclear medicine.

[189]  Marvin Bergsneider,et al.  Improved Parametric Image Generation Using Spatial-Temporal Analysis of Dynamic PET Studies , 2002, NeuroImage.

[190]  Margaret E. Daube-Witherspoon,et al.  A head motion measurement system suitable for emission computed tomography , 1997, IEEE Transactions on Medical Imaging.

[191]  Kuan-Hao Su,et al.  A novel approach for direct reconstruction of parametric images for myocardial blood flow from PET imaging. , 2013, Medical physics.

[192]  Zhizhong Wang,et al.  A study on statistically reliable and computationally efficient algorithms for generating local cerebral blood flow parametric images with positron emission tomography , 1993, IEEE Trans. Medical Imaging.

[193]  Ronald Boellaard,et al.  Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET , 2001, European Journal of Nuclear Medicine.

[194]  Claus Svarer,et al.  Methods for Motion Correction Evaluation Using 18F-FDG Human Brain Scans on a High-Resolution PET Scanner , 2012, The Journal of Nuclear Medicine.

[195]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[196]  Xiao Jin,et al.  Event-by-event respiratory motion correction for PET with 3D internal-1D external motion correlation. , 2013, Medical physics.

[197]  Jan Axelsson,et al.  A Study of Dynamic PET Frame-Binning on the Reference Logan Binding Potential , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.

[198]  A J Reader,et al.  Respiratory motion correction for PET oncology applications using affine transformation of list mode data , 2007, Physics in medicine and biology.

[199]  T. Zeffiro,et al.  Head movement in normal subjects during simulated PET brain imaging with and without head restraint. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[200]  Richard E Carson,et al.  Tracer Kinetic Modeling of [11C]AFM, a New PET Imaging Agent for the Serotonin Transporter , 2008, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[201]  F. Hashimoto,et al.  Denoising of Dynamic Sinogram by Image Guided Filtering for Positron Emission Tomography , 2018, IEEE Transactions on Radiation and Plasma Medical Sciences.

[202]  Ci-Ren Jiang,et al.  Smoothing dynamic positron emission tomography time courses using functional principal components , 2009, NeuroImage.

[203]  Florian Büther,et al.  Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[204]  Tim Mulnix,et al.  Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data , 2018, The Journal of Nuclear Medicine.

[205]  Jianfeng He,et al.  A Novel Method for Respiratory Motion Gated With Geometric Sensitivity of the Scanner in 3D PET , 2008, IEEE Transactions on Nuclear Science.

[206]  F E Turkheimer,et al.  Multiresolution Analysis of Emission Tomography Images in the Wavelet Domain , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[207]  R. Carson,et al.  Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels , 2017, Physics in medicine and biology.

[208]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[209]  L. Nummenmaa,et al.  Simultaneous PET-MRI Confirms That Cerebral Blood Flow Does Not Confound PET Neuroreceptor Activation Studies. , 2018, ACS chemical neuroscience.

[210]  Jeih-San Liow,et al.  Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[211]  Doris J. Doudet,et al.  In Vivo Receptor Assay with Multiple Ligand Concentrations: An Equilibrium Approach , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[212]  Finbarr O'Sullivan,et al.  Use of ridge regression for improved estimation of kinetic constants from PET data , 1999, IEEE Transactions on Medical Imaging.

[213]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[214]  A. Reader,et al.  4D image reconstruction for emission tomography , 2014, Physics in medicine and biology.

[215]  Jeih-San Liow,et al.  Image-derived input function in PET brain studies: blood-based methods are resistant to motion artifacts , 2012, Nuclear medicine communications.

[216]  Raymond F Muzic,et al.  Evaluation of objective functions for estimation of kinetic parameters. , 2006, Medical physics.

[217]  Lei Xing,et al.  Model-based image reconstruction for four-dimensional PET. , 2006, Medical physics.

[218]  Dimitris Visvikis,et al.  Direct 4D patlak parametric image reconstruction algorithm integrating respiratory motion correction for oncology studies , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[219]  Cyril Riddell,et al.  Noninvasive estimation of the aorta input function for measurement of tumor blood flow with [/sup 15/O] water , 2001, IEEE Transactions on Medical Imaging.

[220]  Hans Olsson,et al.  A comparison of recent parametric neuroreceptor mapping approaches based on measurements with the high affinity PET radioligands [11C]FLB 457 and [11C]WAY 100635 , 2006, NeuroImage.

[221]  Robert B. Innis,et al.  Kinetic and equilibrium analyses of [123I]epidepride binding to striatal and extrastriatal dopamine D2 receptors , 1999 .

[222]  G J Meyer,et al.  Accurate local blood flow measurements with dynamic PET: fast determination of input function delay and dispersion by multilinear minimization. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[223]  V. Dhawan,et al.  Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve. , 1993, Radiology.

[224]  Gwenn S. Smith,et al.  Analyses of [18F]altanserin bolus injection PET data. II: Consideration of radiolabeled metabolites in humans , 2001, Synapse.

[225]  Habib Zaidi,et al.  Application of adaptive kinetic modeling for bias propagation reduction in direct 4D image reconstruction , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[226]  M. Senda,et al.  Fast formation of statistically reliable FDG parametric images based on clustering and principal components. , 2002, Physics in medicine and biology.

[227]  Y Yonekura,et al.  Noninvasive estimation of FDG input function for quantification of cerebral metabolic rate of glucose: optimization and multicenter evaluation. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[228]  M. S. Atkins,et al.  Compensation methods for head motion detected during PET imaging , 1996 .

[229]  Tianyu Ma,et al.  Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging , 2016, The Journal of Nuclear Medicine.

[230]  A. Rahmim,et al.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy , 2010, 2008 IEEE Nuclear Science Symposium Conference Record.

[231]  Claudia Kuntner,et al.  A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods. , 2010, Medical physics.

[232]  Yun Zhou,et al.  Linear ridge regression with spatial constraint for generation of parametric images in dynamic positron emission tomography studies , 2001 .

[233]  M. Espeland,et al.  Carotid Arterial Structure in Patients With Documented Coronary Artery Disease and Disease-Free Control Subjects , 2003, Circulation.

[234]  Yun Zhou,et al.  Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction , 2012, Physics in medicine and biology.

[235]  K. Krohn,et al.  Radiolabelled fluoromisonidazole as an imaging agent for tumor hypoxia. , 1989, International journal of radiation oncology, biology, physics.

[236]  C. Patlak,et al.  Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. Generalizations , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[237]  Kris Thielemans,et al.  Using PCA to detect head motion from PET list mode data , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[238]  Jan Pruim,et al.  Comparison of image-derived and arterial input functions for estimating the rate of glucose metabolism in therapy-monitoring 18F-FDG PET studies. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[239]  D. Holt,et al.  Analyses of [18F]altanserin bolus injection PET data. I: Consideration of radiolabeled metabolites in baboons , 2001, Synapse.

[240]  A. A. Lammertsma,et al.  On the use of image-derived input functions in oncological fluorine-18 fluorodeoxyglucose positron emission tomography studies , 1999, European Journal of Nuclear Medicine.

[241]  A A Lammertsma,et al.  Image-derived input functions for determination of MRGlu in cardiac (18)F-FDG PET scans. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[242]  Alessandra Bertoldo,et al.  "Population" approach improves parameter estimation of kinetic models from dynamic PET data , 2004, IEEE Transactions on Medical Imaging.

[243]  Andrew J. Reader,et al.  Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[244]  J. Delforge,et al.  Kinetic Analysis of Central [76Br]Bromolisuride Binding to Dopamine D2 Receptors Studied by PET , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[245]  Xiaoyi Jiang,et al.  Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration , 2012, IEEE Transactions on Medical Imaging.

[246]  Rajendra D. Badgaiyan,et al.  A novel method for noninvasive detection of neuromodulatory changes in specific neurotransmitter systems , 2003, NeuroImage.

[247]  Evan D. Morris,et al.  A linear model for estimation of neurotransmitter response profiles from dynamic PET data , 2012, NeuroImage.

[248]  Michael Brady,et al.  Motion Correction and Attenuation Correction for Respiratory Gated PET Images , 2011, IEEE Transactions on Medical Imaging.

[249]  Xiaoyi Jiang,et al.  Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms , 2008, IEEE Transactions on Medical Imaging.

[250]  Ronald H. Huesman,et al.  List mode reconstruction for PET with motion compensation: a simulation study , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[251]  Guobao Wang,et al.  Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity , 2018, IEEE Transactions on Medical Imaging.

[252]  S. Cherry chapter 21 – Tracer Kinetic Modeling , 2012 .

[253]  D. Feng,et al.  Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input Function , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[254]  Jian Sun,et al.  Guided Image Filtering , 2010, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[255]  Yun Dong,et al.  Real-time data-driven rigid motion detection and correction for brain scan with listmode PET , 2016, 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD).