Viral detection using an embedded piezoresistive microcantilever sensor

The detection of aerosol-based vaccinia virus and solution-based vaccinia virus has been studied using a new type of microsensor design. In the embedded piezoresistive microcantilever (EPM) sensor, a tiny piezoresistive microcantilever is embedded or partially embedded into an active sensing material whose volumetric response to the presence of an analyte is recorded as a strain in the cantilever, and subsequent change in the resistance of the cantilever. In one set of experiments, a composite consisting of poly(ethylene oxide), or PEO, combined with vaccinia antibody was used as the active sensing material. In aerosol exposures, this sensor produced a distinct signal owing to vaccinia virus adsorption/incorporation. In addition, experiments using a piezoresistive microcantilever in direct contact with a pure antibody layer in solution were also performed to detect vaccinia virus in solution. Again, a clear and distinct analyte signals obtained.

[1]  Michael P. Eastman,et al.  Sensor based on piezoresistive microcantilever technology , 2001 .

[2]  Drechsler,et al.  A cantilever array-based artificial nose , 2000, Ultramicroscopy.

[3]  James K. Gimzewski,et al.  An artificial nose based on a micromechanical cantilever array , 1999 .

[4]  N. Lewis,et al.  Use of compatible polymer blends to fabricate arrays of carbon black-polymer composite vapor detectors. , 1998, Analytical chemistry.

[5]  Thomas Thundat,et al.  Micromechanical sensors for chemical and physical measurements , 1995 .

[6]  Toyoichi Tanaka,et al.  Volume phase transition in a nonionic gel , 1984 .

[7]  K. Manygoats,et al.  The interaction of biological molecules with clay minerals: a scanning force microscopy study. , 2006, Scanning.

[8]  Toyoichi Tanaka,et al.  Saccharide-sensitive phase transition of a lectin-loaded gel , 1991, Nature.

[9]  N S Lewis,et al.  Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors for the nerve agent simulants dimethylmethylphosphonate and diisopropylmethylphosponate. , 2001, Analytical chemistry.

[10]  Thomas Thundat,et al.  Thermal and ambient-induced deflections of scanning force microscope cantilevers , 1994 .

[11]  Takashi Miyata,et al.  A reversibly antigen-responsive hydrogel , 1999, Nature.

[12]  Toyoichi Tanaka Collapse of Gels and the Critical Endpoint , 1978 .

[13]  Y. Osada,et al.  A polymer gel with electrically driven motility , 1992, Nature.

[14]  N S Lewis,et al.  Quantitative study of the resolving power of arrays of carbon black-polymer composites in various vapor-sensing tasks. , 1998, Analytical chemistry.