Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties.

Phase contrast techniques in combination with k-space segmented CINE imaging are widely used for the quantitative assessment of blood flow or tissue motion. The temporal resolution of the corresponding pulse sequences plays an important role concerning the potential of the method to fully detect time resolved flow or motion patterns. A further improvement of temporal or spatial resolution in phase contrast CINE MRI can be achieved by the application of view sharing. Based on simulations with point-spread-functions resulting from different cyclic flow or motion patterns an analysis of view sharing techniques in combination with phase contrast MRI is presented. Velocity mapping properties and the role of different k-space regions concerning the resulting values in the phase images and thus encoded velocities were investigated. It could be shown that the velocity induced phase shifts in phase contrast techniques are mainly encoded in the central sections of k-space which makes view sharing also suitable for velocity mapping. As a result the use of appropriate sampling and data acquisition schemes permits the assessment of flow or motion patterns with significantly improved temporal resolution without loss of functional information. In addition phantom measurements with an oscillation phantom were performed in order to validate the simulation results and to demonstrate the potential of view sharing techniques to accelerate phase contrast imaging and improve the detection of the underlying flow or motion dynamics.

[1]  Michael Markl,et al.  Analysis of myocardial motion based on velocity measurements with a black blood prepared segmented gradient‐echo sequence: Methodology and applications to normal volunteers and patients , 1998, Journal of magnetic resonance imaging : JMRI.

[2]  C L Dumoulin,et al.  Quantitative flow measurement in phase contrast MR angiography. , 1988, Journal of computer assisted tomography.

[3]  T K Foo,et al.  Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques. , 1995, Radiology.

[4]  X Hu,et al.  Hybrid technique for dynamic imaging , 2000, Magnetic resonance in medicine.

[5]  G. Pohost,et al.  Block Regional Interpolation Scheme for k‐Space (BRISK): A Rapid Cardiac Imaging Technique , 1995, Magnetic resonance in medicine.

[6]  P Boesiger,et al.  Heart motion adapted cine phase‐contrast flow measurements through the aortic valve , 1999, Magnetic resonance in medicine.

[7]  D N Firmin,et al.  In vivo validation of MR velocity imaging. , 1987, Journal of computer assisted tomography.

[8]  C L Dumoulin,et al.  Phase contrast MR angiography techniques. , 1995, Magnetic resonance imaging clinics of North America.

[9]  D N Firmin,et al.  Magnetic resonance velocity mapping. , 1990, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  R. Balaban,et al.  Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia , 1999, Magnetic resonance in medicine.

[11]  B. Carroll,et al.  Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation. , 1997, AJR. American journal of roentgenology.

[12]  D. Pennell,et al.  MR blood flow measurement. Clinical application in the heart and circulation. , 1998, Cardiology clinics.

[13]  T. Grist,et al.  Measurement of coronary blood flow and flow reserve using magnetic resonance imaging. , 1997, Cardiology.

[14]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[15]  K. Rossmann Point spread-function, line spread-function, and modulation transfer function. Tools for the study of imaging systems. , 1969, Radiology.

[16]  D N Firmin,et al.  The application of phase shifts in NMR for flow measurement , 1990, Magnetic resonance in medicine.

[17]  N J Pelc,et al.  In vitro verification of myocardial motion tracking from phase-contrast velocity data. , 1998, Magnetic resonance imaging.

[18]  J. Hennig,et al.  K-space sampling strategies , 1999, European Radiology.

[19]  E. McVeigh MRI of myocardial function: motion tracking techniques. , 1996, Magnetic resonance imaging.

[20]  E M Haacke,et al.  Cardiac MR Imaging: Principles and Techniques , 1995, Topics in magnetic resonance imaging : TMRI.

[21]  C Thomsen,et al.  A segmented k‐space velocity mapping protocol for quantification of renal artery blood plow during breath‐holding , 1995, Journal of magnetic resonance imaging : JMRI.

[22]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[23]  G M Pohost,et al.  Rapid cardiac imaging with turbo BRISK , 1997, Magnetic resonance in medicine.

[24]  R Frayne,et al.  Frequency response of multi‐phase segmented k‐space phase‐contrast , 1996, Magnetic resonance in medicine.

[25]  F Schick,et al.  Evaluation of K-space segmented cine sequences for fast functional cardiac imaging. , 1996, Investigative radiology.

[26]  O. Haraldseth,et al.  K‐space substitution: A novel dynamic imaging technique , 1993, Magnetic resonance in medicine.

[27]  R. Herfkens,et al.  Evaluation of Myocardial Motion Tracking With Cine-Phase Contrast Magnetic Resonance Imaging , 1994, Investigative radiology.