Interline Power Flow Controller (IPFC) Deployment in Long Transmission Lines and its Effects on Distance Relay

This article presents apparent impedance calculations of the existing transmission lines and their distance protection zone 1, zone 2, and zone 3 settings when the interline power flow controller is deployed on the existing transmission lines. An interline power flow controller (IPFC) can considerably affect the performance of a distance relay in an existing transmission line. Installation of IPFC into an existing transmission line near generating plants is challenging in terms of installation of the IPFC in an available place and changing existing protection setting requirements of a transmission line. Due to the deployment of the IPFC into the transmission line, there will be a change in transmission line apparent impedance that will affect the zone settings of the distance relay. These zone settings play a major role in the protection of transmission lines. The application of IPFC is to control power flows of multiple transmission lines with different loading conditions. Distance protection setting calculations are performed on 2X660MW Singhitarai power plant (Chhattisgarh, India) 400 kV outgoing lines with the existing MICOM P443 distance relay with and without deployment of the IPFC. Zone settings for the line to ground (L–G) fault and three-phase faults are analyzed and the results are presented.

[1]  R.K. Aggarwal,et al.  Performance evaluation of a distance relay as applied to a transmission system with UPFC , 2006, IEEE Transactions on Power Delivery.

[2]  Raj Naidoo,et al.  Adaptive digital distance relay for SSSC‐based double‐circuit transmission line using phasor measurement unit , 2018, International Transactions on Electrical Energy Systems.

[3]  Ganapati Panda,et al.  Distance protection in the presence of unified power flow controller , 2000 .

[4]  A. Salemnia,et al.  Impact of static synchronous compensator (STATCOM) on performance of distance relay , 2009, 2009 IEEE Bucharest PowerTech.

[5]  Almoataz Y. Abdelaziz,et al.  Synchrophasors assisted protection scheme for the shunt-compensated transmission line , 2017 .

[6]  Ganapati Panda,et al.  Adaptive relay setting for flexible AC transmission systems (FACTS) , 2000 .

[7]  A. Kazemi,et al.  Modified distance protection due to presence of STATCOM on a transmission line , 2009, 2009 IEEE Bucharest PowerTech.

[8]  Azam Karami,et al.  VOLTAGE SECURITY ENHANCEMENT AND CONGESTION MANAGEMENT VIA STATCOM & IPFC USING ARTIFICIAL INTELLIGENCE , 2007 .

[9]  Devesh Raj Saxena Multi-Line power Flow Control Using Interline Power Flow Controller (IPFC) in Power Transmission system , 2013 .

[10]  H. Shateri,et al.  Locus of apparent impedance of distance protection in the presence of SSSC , 2011 .

[11]  A. Salemnia,et al.  Impact of SSSC on the digital distance relaying , 2009, 2009 IEEE Power & Energy Society General Meeting.

[12]  Claus Leth Bak,et al.  Variation of UPFC controllable parameters during power swing and their impacts on distance relay , 2017 .

[13]  Gevork B. Gharehpetian,et al.  Performance analysis of distance relay in presence of unified interphase power controller and voltage-source converters-based interphase power controller , 2015 .

[14]  Bijay Ketan Panigrahi,et al.  Simultaneous impact of unified power flow controller and off-shore wind penetration on distance relay characteristics , 2014 .

[15]  Sirigiri Sivanagaraju,et al.  POWER FLOW ANALYSIS OF A POWER SYSTEM IN THE PRESENCE OF INTERLINE POWER FLOW CONTROLLER (IPFC) , 2010 .

[16]  Mohan P. Thakre,et al.  An adaptive approach for three zone operation of digital distance relay with Static Var Compensator using PMU , 2016 .

[17]  Sukumar Brahma,et al.  Development of adaptive protection scheme for distribution systems with high penetration of distributed generation , 2004 .

[18]  T.S. Sidhu,et al.  Performance of distance relays on shunt-FACTS compensated transmission lines , 2005, IEEE Transactions on Power Delivery.

[19]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[20]  Paresh Kumar Nayak,et al.  State-of-the-art on the protection of FACTS compensated high-voltage transmission lines: a review , 2018 .

[21]  T.S. Sidhu,et al.  Performance Comparison of Distance Protection Schemes for Shunt-FACTS Compensated Transmission Lines , 2007, IEEE Transactions on Power Delivery.