Robust Heartbeat Detector Based on Weighted Correlation and Multichannel Input: Implementation on the ECG Recorded with Textile Electrodes

The aim of this study was to develop and evaluate a robust heartbeat detector for noisy electrocardiograms (ECGs) recorded with textile electrodes. The authors suggest a method based on weighted correlation in a multi-channel ECG to obtain a heartbeat detector. Signals were acquired during rest and at movements which simulate every day activities. From each recording a segment corresponding to a heartbeat was extracted and correlated with the whole signal. From the correlation data, heartbeat candidates were derived and weighted based on their variance similarity with the heartbeat model and previous heartbeats. Finally, the outputs of each channel were added to create the global output. The output was compared to the Pan Tompkins heartbeat detector. Results are promising for recordings at rest (sensitivity = 0.97, positive predictive value (PPV) = 0.97). For static muscle tension in the torso the results were much higher than the reference method (sensitivity = 0.77, PPV = 0.85). Corresponding values for the reference method were sensitivity = 0.96 and PPV = 0.95 at rest and sensitivity = 0.52 and PPV = 0.75 during muscle tension.

[1]  Maria Lindén,et al.  A Canonical correlation approach to heart beat detection in textile ECG measurements , 2006 .

[2]  Maria Lindén,et al.  Electrical characteristics of conductive yarns and textile electrodes for medical applications , 2007, Medical & Biological Engineering & Computing.

[3]  A. Rickards,et al.  Relation between QT interval and heart rate. New design of physiologically adaptive cardiac pacemaker. , 1981, British heart journal.

[4]  Robert Puers,et al.  Towards the integration of textile sensors in a wireless monitoring suit , 2004 .

[5]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[6]  Fabrice Axisa,et al.  Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention , 2005, IEEE Transactions on Information Technology in Biomedicine.

[7]  S. Ödman,et al.  Movement-induced potentials in surface electrodes , 1982, Medical and Biological Engineering and Computing.

[8]  Marcus Karlsson,et al.  Adaptive spatio-temporal filtering of disturbed ECGs: a multi-channel approach to heartbeat detection in smart clothing , 2007, Medical & Biological Engineering & Computing.

[9]  Enzo Pasquale Scilingo,et al.  Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables , 2005, IEEE Transactions on Information Technology in Biomedicine.

[10]  Paul Kiekens,et al.  Quality Control of Textile Electrodes by Electrochemical Impedance Spectroscopy , 2006 .