Primary TKA With a Zirconia Ceramic Femoral Component

This article presents the 2-year clinical results of primary total knee arthroplasty (TKA) performed with a zirconia ceramic femoral component. A posterior-stabilized TKA was performed for degenerative arthritis in 36 patients (39 knees). The components included a zirconia femoral component, a cobalt-chrome alloy tibial baseplate, and a polyethylene patella; all were implanted with bone cement. The ultra-high molecular-weight polyethylene-bearing insert had a deep-dish, ultra-congruent design. At the 2-year interval, mean Western Ontario and McMaster Universities (WOMAC) osteoarthritis indices improved from 41 to 86, and mean Knee Society Scores improved from 40 to 92. Revision to constrained implants was necessary in one patient for persistent knee instability after trauma. These early results are encouraging, but more data are needed to determine whether ceramics are a suitable alternative to metal countersurfaces in TKAs.

[1]  J. Chevalier,et al.  Low‐Temperature Aging of Y‐TZP Ceramics , 2004 .

[2]  S. Catledge,et al.  Examination of surface and material properties of explanted zirconia femoral heads. , 2004, The Journal of arthroplasty.

[3]  R. Laskin The Use of a Ceramic Surfaced Oxinium™ Implant in Total Knee Replacement , 2004 .

[4]  J. Jacobs,et al.  Metal degradation products: a cause for concern in metal-metal bearings? , 2003, Clinical orthopaedics and related research.

[5]  R. Laskin An Oxidized Zr Ceramic Surfaced Femoral Component for Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.

[6]  H. Oonishi,et al.  Development and Improvement of Ceramic TKP for 19 Years and Clinical Results , 2001 .

[7]  R. Bourne,et al.  Wear Performance of Ultra-High Molecular Weight Polyethylene on Oxidized Zirconium Total Knee Femoral Components , 2001, The Journal of bone and joint surgery. American volume.

[8]  A S Greenwald,et al.  Alternative Bearing Surfaces: The Good, the Bad, and the Ugly , 2001, The Journal of bone and joint surgery. American volume.

[9]  M. Ries,et al.  Relationship Between Gravimetric Wear and Particle Generation in Hip Simulators: Conventional Compared with Cross-Linked Polyethylene , 2001, The Journal of bone and joint surgery. American volume.

[10]  N. Sugano,et al.  Phase transformation of a zirconia ceramic head after total hip arthroplasty. , 2001, The Journal of bone and joint surgery. British volume.

[11]  M A Ritter,et al.  Long-Term Followup of Anatomic Graduated Components Posterior Cruciate-Retaining Total Knee Replacement , 2001, Clinical orthopaedics and related research.

[12]  M. Akagi,et al.  The Bisurface Total Knee Replacement: A Unique Design for Flexion Four-to-Nine-Year Follow-up Study* , 2000, The Journal of bone and joint surgery. American volume.

[13]  B. Calès Zirconia as a sliding material: histologic, laboratory, and clinical data. , 2000, Clinical orthopaedics and related research.

[14]  H. Oonishi,et al.  3 to 18 Year Clinical Results of Total Knee Replacement with Ceramic Components , 2000 .

[15]  F. Kummer,et al.  Alternative bearing surfaces for total joint arthroplasty. , 1998, The Journal of the American Academy of Orthopaedic Surgeons.

[16]  D. Dowson,et al.  The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  L. Whiteside,et al.  Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. , 1994, Clinical orthopaedics and related research.

[18]  J. Galante,et al.  Wear Debris in Total Joint Replacements , 1994, The Journal of the American Academy of Orthopaedic Surgeons.

[19]  B. Calès,et al.  Long-term in vivo and in vitro aging of a zirconia ceramic used in orthopaedy. , 1994, Journal of biomedical materials research.

[20]  H. Oonishi,et al.  Alumina versus polyethylene in total knee arthroplasty. , 1992, Clinical orthopaedics and related research.

[21]  A Walter,et al.  On the material and the tribology of alumina-alumina couplings for hip joint prostheses. , 1992, Clinical orthopaedics and related research.

[22]  F. C. Ewald The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. , 1989, Clinical orthopaedics and related research.

[23]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[24]  C. Lohmann,et al.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. , 2005, The Journal of bone and joint surgery. American volume.

[25]  J. Stiehl,et al.  The spectrum of prosthesis design for primary total knee arthroplasty. , 2003, Instructional course lectures.

[26]  J. Heckman,et al.  Selected Instructional Course Lectures The American Academy of Orthopaedic Surgeons , 2000 .

[27]  C. Piconi,et al.  Zirconia as a ceramic biomaterial. , 1999, Biomaterials.

[28]  K. Kaneda,et al.  Low friction total knee arthroplasty with the alumina ceramic condylar prosthesis. , 1993, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).