Shape and Contact Force Estimation of Inserted Flexible Medical Device

Flexible devices such as colonoscopy tube or catheter being inserted into the human-body make contact with the human tissues at several locations. Excessive contact force may damage the human tissues. To cope with this problem, the first aim of this paper is the shape estimation of the flexible body inside the human body using only two electromagnetic sensors. For this, the flexible body is modeled as kinematically redundant manipulator with many joints and links. The second aim is to estimate contact forces at a point, line contact, and multiple points. Cosserat-rod theory is employed to solve this problem. The effectiveness of the proposed algorithms is proved through both experiment and simulation for a flexible colonoscopy tube.

[1]  S. Antman Nonlinear problems of elasticity , 1994 .

[2]  Kawal Rhode,et al.  Three dimensional force estimation for steerable catheters through bi-point tracking , 2018, Sensors and Actuators A: Physical.

[3]  Pietro Valdastri,et al.  Six DOF motion estimation for teleoperated flexible endoscopes using optical flow: A comparative study , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[4]  Kaspar Althoefer,et al.  New kinematic multi-section model for catheter contact force estimation and steering , 2016, 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[5]  Bruno Siciliano,et al.  Kinematic control of redundant robot manipulators: A tutorial , 1990, J. Intell. Robotic Syst..

[6]  J. Bruce C. Davies,et al.  Continuum robots - a state of the art , 1999, Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C).

[7]  Timothy Bretl,et al.  Mechanics and Quasi-Static Manipulation of Planar Elastic Kinematic Chains , 2013, IEEE Transactions on Robotics.

[8]  Kai Xu,et al.  Analytic Formulation for Kinematics, Statics, and Shape Restoration of Multibackbone Continuum Robots Via Elliptic Integrals , 2010 .

[9]  Richard M. Murray,et al.  A Mathematical Introduction to Robotic Manipulation , 1994 .

[10]  Ian D. Walker,et al.  Dynamic Modelling for Planar Extensible Continuum Robot Manipulators , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[11]  Byung-Ju Yi,et al.  Kinematic modelling and configuration estimation for elastic wire using minimum sensors , 2015 .

[13]  Sang-Rok Oh,et al.  Control design for human-like reaching movements using redundancy in robot arm-trunk systems , 2011 .

[14]  Garret N. Vanderplaats,et al.  Numerical optimization techniques for engineering design , 1999 .

[15]  Takashi Maeno,et al.  Development of a Master-Slave System for Active Endoscope Using a Multi-DOF Ultrasonic Motor , 2002 .

[16]  Kaspar Althoefer,et al.  Catheter contact force estimation from shape detection using a real-time Cosserat rod model , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[17]  Youngjin Choi,et al.  New form of block matrix inversion , 2009, 2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[18]  Ian D. Walker,et al.  Design and experimental testing of the OctArm soft robot manipulator , 2006, SPIE Defense + Commercial Sensing.

[19]  Seong Young Ko,et al.  Feasibility study on magnetically steerable guidewire device for percutaneous coronary intervention , 2017 .

[20]  Hosang Jung,et al.  Development of a smart handheld surgical tool with tactile feedback , 2017, Intell. Serv. Robotics.

[21]  Daniel Caleb Rucker,et al.  The mechanics of continuum robots: Model-based sensing and control , 2011 .

[22]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[23]  Tsuneo Yoshikawa,et al.  Manipulability and redundancy control of robotic mechanisms , 1985, Proceedings. 1985 IEEE International Conference on Robotics and Automation.

[24]  Byung-Ju Yi,et al.  Application of Cosserat Rod Theory to Configuration Estimation of Coionoscope , 2018, 2018 15th International Conference on Ubiquitous Robots (UR).

[25]  Wang,et al.  development of a continuum robot for colonoscopy , 2009 .

[26]  Sarthak Misra,et al.  Force sensing in continuum manipulators using fiber Bragg grating sensors , 2017, 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[27]  Ian D. Walker,et al.  New dynamic models for planar extensible continuum robot manipulators , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[28]  Byung-Ju Yi,et al.  A continuum module for developing a biopsy device , 2012, 2012 9th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI).

[29]  Christian Duriez,et al.  Motion Control of Cable-Driven Continuum Catheter Robot Through Contacts , 2019, IEEE Robotics and Automation Letters.

[30]  I. Walker,et al.  NOVEL KINEMATICS FOR CONTINUUM ROBOTS , 2000 .