Overcurrent Relay based Integrated Protection Scheme for Distribution Systems

This paper reports on the development of integrated protection for power system. The background of the development is firstly introduced, in which a centralized protection system (or relay) provides the protection of multiple power plant or a substation. A novel integrated protection scheme for distribution system is described. The scheme is based on overcurrent protection technique, in which specially designed protection relays are installed at each substation of a network. In the proposed scheme, one integrated relay is responsible for the protection of every line sections connected to the substation busbar. The conventional directional overcurrent and new adaptive accelerated protection algorithms are implemented into the relay with multiple overcurrent settings to cover all the protected line sections. The paper includes studies of a typical multi section distribution network to demonstrate the principle of the scheme. Studies show that the new scheme not only offer the new protection features for individual power line, but also provide the characteristics of integrated protection.

[1]  Z. Q. Bo,et al.  A new non-communication protection technique for transmission lines , 1998 .

[2]  Xinzhou Dong,et al.  Non-communication protection for radial connected distribution systems , 2004 .

[3]  X.Z. Dong,et al.  Application of percentage cross differential relay in EHV double lines , 2005, 2005 IEEE Russia Power Tech.

[4]  C. K. Chan,et al.  EXPLORING THE INTERNET FOR ON-LINE MONITORING AND CONTROL OF SUBSTATION PROTECTIVE RELAYS , 2005 .

[5]  P. Crossley,et al.  Distance Protection Based on Travelling Waves , 1983, IEEE Transactions on Power Apparatus and Systems.

[6]  Zhao Yang Dong,et al.  Non-communication protection of distribution feeders with tapped-off-loads , 2002, Proceedings. International Conference on Power System Technology.

[7]  Wang Kui,et al.  Quickaction Feeder Protection Based on Wireless CDMA Communications , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[8]  Armando Guzmán,et al.  Integrated Transformer, Feeder, and Breaker Protection: An Economic and Reliable Solution for Distribution Substations , 2000 .

[9]  Xinzhou Dong,et al.  Evaluation of an Accelerated Overcurrent Protection for Single Circuit Breaker Distribution Feeder , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[10]  B. Kulicke,et al.  Multi neural network based fault area estimation for high speed protective relaying , 1996 .

[11]  J. R. Linders,et al.  Adaptive transmission relaying concepts for improved performance , 1988 .

[12]  A. T. Johns,et al.  New ultra-high-speed directional comparison technique for the protection of e.h.v. transmission lines , 1980 .

[13]  Arun G. Phadke,et al.  Adaptive transmission system relaying , 1988 .

[14]  Zhiqian Bo,et al.  Development of non-communication relays for transmission and distribution systems , 2004 .

[15]  R.K. Aggarwal,et al.  A New Approach to Phase Selection Using Fault Generated High Frequency Noise and Neural Networks , 1997, IEEE Power Engineering Review.

[16]  M. Vitins,et al.  A Fundamental Concept for High Speed Relaying , 1981, IEEE Transactions on Power Apparatus and Systems.

[17]  Xinzhou Dong,et al.  An New Directional Comparison Scheme for Distribution Line Protection , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[18]  G. Weller,et al.  Positional protection of transmission systems using Global Positioning System , 2000 .

[19]  M C Meyer,et al.  The application of an artificial neural network and pharmacokinetic simulations in the design of controlled-release dosage forms. , 1999, Journal of controlled release : official journal of the Controlled Release Society.

[20]  P. Bastard,et al.  Neural network-based algorithm for power transformer differential relays , 1995 .

[21]  Mladen Kezunovic,et al.  High-speed fault detection and classification with neural nets , 1995 .

[22]  Yang Qi-xun Technical Development and Analysis on Modern Microprocessor-based Protection , 2003 .

[23]  A. T. Johns,et al.  Non-unit protection technique for EHV transmission systems based on fault-generated noise. Part 1: signal measurement , 1994 .

[24]  M. Chamia,et al.  Ultra High Speed Relay for EHV/UHV Transmission Lines -- Development, Design and Application , 1978, IEEE Transactions on Power Apparatus and Systems.

[25]  He Ben-teng TRANSMISSION LINE AGGREGATE PROTECTION AND ITS IMPLEMENTATION , 2005 .

[26]  Z.Q. Bo,et al.  Application of Transient Polarity Comparison Technique to Power System Protection , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[27]  W. Cong,et al.  A Wide Area Protection System and Division of Protection lED Associated Area Based on Petri Net , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[28]  M. S. Sachdev,et al.  Design, implementation and testing of an artificial neural network based fault direction discriminator for protecting transmission lines , 1995 .

[29]  G. D. Rockefeller,et al.  Fault Protection with a Digital Computer , 1969 .