Aspergillus terreus Infections in Patients With Hematologic Malignancies

tor circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia. Chest 1998;113:405-411. 22. Han JN, Liu YP, Ma S, et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilatorassociated pneumonia in a Beijing hospital. Respir Care 2001;46:891896. 23. Alfredson T, Earl A, Larson R, et al. Effect of extending ventilator circuit changes from 2 to 7 days. Respir Care 1994;39:161. 24. Krause S, Fisher M, Fink J. Reduction of ventilator associated pneumonias with seven day circuit changes. Respir Care 1994;39:164. 25. Goodhart G, Gilliam C. Developing a program for monitoring ventilator associated nosocomial infections. Respir Care 1994;39:90. 26. Gastmeier P, Wendt C, Ruden H. Breathing circuit exchange in intensive care: once daily or once weekly? Anaesthesist 1997;46:943-948. 27. Craven DE, Connolly MG, Lichtenberg DA, Primeau PJ, McCabe WR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med 1982;306:1505-1509. 28. Dreyfuss D, Djedaini K, Weber P, et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 8 hours versus no change. Am Rev Respir Dis 1991;143:738-743.

[1]  H. Rüden,et al.  [Breathing circuit exchange in intensive care. Once daily once weekly?]. , 1997, Der Anaesthesist.

[2]  M. A. de la Cal,et al.  How to classify infections in intensive care units--the carrier state, a criterion whose time has come? , 1996, The Journal of hospital infection.

[3]  D. Dreyfuss,et al.  Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. , 1991, The American review of respiratory disease.

[4]  B. Make,et al.  Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. , 1986, The American review of respiratory disease.

[5]  W. R. Mccabe,et al.  Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. , 1982, The New England journal of medicine.

[6]  S. Lareau,et al.  The relationship between frequency of ventilator circuit changes and infectious hazard. , 2015, The American review of respiratory disease.

[7]  B. Eberle,et al.  Pseudomonas aeruginosa respiratory tract infection acquired from a contaminated anesthesia machine. , 1972, The American review of respiratory disease.

[8]  J. A. Zadeh,et al.  Infection by anaesthetic apparatus. , 1968, Lancet.

[9]  W. H. Bain,et al.  Cross-infection by Pseudomonas aeruginosa as a hazard of intensive surgery. , 1967, British medical journal.

[10]  I. Phillips,et al.  Pseudomonas aeruginosa cross-infection due to contaminated respiratory apparatus. , 1965, Lancet.

[11]  J. M. Joseph Disease transmission by inefficiently sanitized anesthetizing apparatus. , 1952, Journal of the American Medical Association.