Intra‐examiner repeatability and agreement in accommodative response measurements

Purpose:  Clinical measurement of the accommodative response (AR) identifies the focusing plane of a subject with respect to the accommodative target. To establish whether a significant change in AR has occurred, it is important to determine the repeatability of this measurement. This study had two aims: First, to determine the intraexaminer repeatability of AR measurements using four clinical methods: Nott retinoscopy, monocular estimate method (MEM) retinoscopy, binocular crossed cylinder test (BCC) and near autorefractometry. Second, to study the level of agreement between AR measurements obtained with the different methods.

[1]  D. B. E. P. M. Faao Clinical Procedures in Primary Eye Care , 2003 .

[2]  Rent M. Daum,et al.  CLINICAL MANAGEMENT OF BINOCULAR VISION: HETEROPHORIC, ACCOMMODATIVE AND EYE MOVEMENT DISORDERS , 1994 .

[3]  A J Adams,et al.  The repeatability of measurement of the ocular components. , 1992, Investigative ophthalmology & visual science.

[4]  L C Locke,et al.  A Comparison Study of Dynamic Retinoscopy Techniques , 1989, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  J. J. Villa,et al.  Capítulo 9 – Estudios descriptivos , 2004 .

[7]  B Gilmartin,et al.  Effect of target proximity on the open-loop accommodative response. , 1990, Optometry and vision science : official publication of the American Academy of Optometry.

[8]  R. Held,et al.  Myopic children show insufficient accommodative response to blur. , 1993, Investigative ophthalmology & visual science.

[9]  Gang Tao,et al.  A Comparison Study , 2003 .

[10]  Jackson Tw,et al.  Variation and correlation of clinical tests of accommodative function in a sample of school-age children. , 1991 .

[11]  J. Tassinari,et al.  Comparison between MEM and Nott dynamic retinoscopy. , 2000, Optometry and vision science : official publication of the American Academy of Optometry.

[12]  J S Wolffsohn,et al.  Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[13]  D. Goss Clinical accommodation testing , 1992, Current opinion in ophthalmology.

[14]  W. Charman,et al.  Dynamic retinoscopy and accommodation , 1992, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[15]  J S Wolffsohn,et al.  Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[16]  J. J. Saladin,et al.  Chapter 21 – Phorometry and Stereopsis , 2006 .

[17]  D. Goss,et al.  COMPARISON OF MEM RETINOSCOPY & NOTT RETINOSCOPY & THEIR INTEREXAMINER REPEATABILITIES , 2005 .

[18]  K. Saunders,et al.  The repeatability and validity of dynamic retinoscopy in assessing the accommodative response , 2003, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[19]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[20]  J. Wolffsohn,et al.  Clinical Evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K Autorefractor , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[21]  J. A. Holterman OPTOMETRIC MANAGEMENT OF NEARPOINT VISION DISORDERS , 1994 .

[22]  R. Greer Clinical Procedures in Primary Eye Care , 1998 .

[23]  M. Rosenfield,et al.  Comparison of Clinical Techniques to Assess the Near Accommodative Response , 1996, Optometry and vision science : official publication of the American Academy of Optometry.

[24]  James S. Wolffsohn,et al.  Continuous recording of accommodation and pupil size using the Shin‐Nippon SRW‐5000 autorefractor , 2001 .

[25]  K. Zadnik The ocular examination : measurements and findings , 1997 .

[26]  T. W. Jackson,et al.  Variation and correlation of clinical tests of accommodative function in a sample of school-age children. , 1991, Journal of the American Optometric Association.

[27]  J S Wolffsohn,et al.  Simultaneous continuous recording of accommodation and pupil size using the modified Shin‐Nippon SRW‐5000 autorefractor , 2004, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[28]  S. Chat,et al.  Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[29]  N Flax,et al.  Clinical assessment of accommodative facility in symptomatic and asymptomatic individuals. , 1985, Journal of the American Optometric Association.

[30]  M. Rouse,et al.  An Evaluation of the Monocular Estimate Method of Dynamic Retinoscopy , 1982, American journal of optometry and physiological optics.

[31]  James S. Wolffsohn,et al.  Clinical evaluation of the Shin‐Nippon SRW‐5000 autorefractor in adults , 2001 .

[32]  Howard C. Howland,et al.  Chapter 18 – Objective Refraction: Retinoscopy, Autorefraction, and Photorefraction , 2006 .

[33]  Hiroshi Ohtsuki,et al.  Accommodative lag under habitual seeing conditions: comparison between adult myopes and emmetropes. , 2003, Japanese journal of ophthalmology.