The Advanced Test Reactor (ATR) Full size plate In center flux trap Position (AFIP) experiment AFIP-2 was designed to evaluate the performance of monolithic fuels at a prototypic scale of 2.25 inches x 21.5 inches x 0.050 inches (5.75 cm x 54.6 cm x 0.13cm). The AFIP-2 experiment was fabricated by friction bond (FB) and consists of two plates, one with a zirconium (Zr) diffusion barrier and one with a silicon (Si) enhanced fuel/clad interface1,2. The following report summarizes the life of the AFIP-2 experiment through end of irradiation, including a brief description of the safety analysis, as-run neutronic analysis results, hydraulic testing results, and thermal analysis results. The safety analyses performed for AFIP-2 are summarized in Table 5 of the following report.