Robust Design of a TCSC Oscillation Damping Controller in a Weak 500-kV Interconnection Considering Multiple Power Flow Scenarios and External Disturbances

The power oscillation damping (POD) controllers implemented in the two thyristor controlled series compensators of the Brazilian North-South (NS) interconnection, in the year 1999, were solely intended to damp the low-frequency NS oscillation mode. These controllers are still under operation and are derived from the modulus of the active power flow in the NS line that is phase-lagged at the frequency of the NS mode and may experience relatively large excursions generated by exogenous disturbances. This paper utilizes the same 1999 data to compare the performance of a proposed robust POD controller design with those of two conventional designs. A recent robust control synthesis algorithm used in this work is based on a nonsmooth optimization technique and has the capability to handle various controller structures, including reduced-order, and to deal with time-domain constraints on both controlled and measured outputs. Moreover, the nonsmooth design technique encompasses multiple operating conditions subject to various test signals, hence building a truly time-domain multi-scenarios approach. According to the results discussed hereafter, this is a key advantage in the industrial context of increasing demand for performance and robustness. The described results relate to a large-scale system model used in the feasibility studies for that interconnection.

[1]  P.C. Pellanda,et al.  Robust Signals for the TCSC Oscillation Damping Controllers of the Brazilian North-South Interconnection Considering Multiple Power Flow Scenarios and External Disturbances , 2007, 2007 IEEE Power Engineering Society General Meeting.

[2]  N. Christl Advanced Series Compensation (ASC) with Thyristor Controlled Impedance , 1992 .

[3]  Pierre Apkarian,et al.  Nonsmooth H∞ synthesis , 2005, IEEE Trans. Autom. Control..

[4]  Joe H. Chow,et al.  A robust frequency domain optimization technique for tuning series compensation damping controllers , 1995 .

[5]  L. A. Aguirre Quantitative measure of modal dominance for continuous systems , 1993, Proceedings of 32nd IEEE Conference on Decision and Control.

[6]  N. Martins,et al.  Efficient computation of transfer function dominant poles using subspace acceleration , 2006, IEEE Transactions on Power Systems.

[7]  A. de Castro,et al.  Utilizing transfer function modal equivalents of low-order for the design of power oscillation damping controllers in large power systems , 2005, IEEE Power Engineering Society General Meeting, 2005.

[8]  L. Angquist,et al.  Power oscillation damping using controlled reactive power compensation-a comparison between series and shunt approaches , 1993 .

[9]  Pierre Apkarian,et al.  Control design in the time and frequency domain using nonsmooth techniques , 2008, Syst. Control. Lett..

[10]  Pierre Apkarian,et al.  IQC analysis and synthesis via nonsmooth optimization , 2006, Syst. Control. Lett..

[11]  Joe H. Chow,et al.  Power system reduction to simplify the design of damping controllers for interarea oscillations , 1996 .

[12]  Pierre Apkarian,et al.  Mixed H2/Hinfinity Control via Nonsmooth Optimization , 2008, SIAM J. Control. Optim..

[13]  M. Noroozian,et al.  Damping of power system oscillations by use of controllable components , 1994 .

[14]  J. Doyle,et al.  Essentials of Robust Control , 1997 .

[15]  N. Martins,et al.  Efficient Computation of Multivariable Transfer Function Dominant Poles Using Subspace Acceleration , 2006, IEEE Transactions on Power Systems.

[16]  Joe H. Chow,et al.  Concepts for design of FACTS controllers to damp power swings , 1995 .

[17]  Joe H. Chow,et al.  A comparison of classical, robust, and decentralized control designs for multiple power system stabilizers , 2000 .

[18]  N. Martins,et al.  Retuning stabilizers for the north-south Brazilian interconnection , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[19]  G. Ingeström COMMISSIONING AND OPERATIVE EXPERIENCE OF TCSC FOR DAMPING POWER OSCILLATION IN THE BRAZILIAN NORTH-SOUTH INTERCONNECTION , 2000 .

[20]  David J. N. Limebeer,et al.  Linear Robust Control , 1994 .

[21]  C. Portela,et al.  Computing small-signal stability boundaries for large-scale power systems , 2002 .