Small cavity creation in the vertebral body reduces the rate of cement leakage during vertebroplasty

Cement leakage is the most common complication during vertebroplasty and may result in serious morbidity. Measures to reduce the rate of cement leakage are valuable ways to improve vertebroplasty safety. The present study aimed to evaluate whether creating a small cavity in the vertebral body prior to cement injection would reduce the rate of cement leakage during vertebroplasty. The study included 36 consecutive patients with 42 painful osteoporotic vertebral body compression fractures that were classified as A1 fractures according to AO classification. Patients were randomly assigned to receive either treatment with vertebroplasty (control) or with a procedure termed cavuplasty, in which a small cavity was created in the vertebral body prior to cement injection. CT scanning was performed to detect cement leakage. Cement leakage was observed in 14 (66.6%) of the 21 vertebral bodies treated with vertebroplasty and 5 (23.8%) of the 21 vertebral bodies treated with cavuplasty (p = 0.012). These results suggest that the creation of a small cavity in the vertebral body prior to cement injection is an effective way to reduce cement leakage during vertebroplasty. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:154–159, 2017.

[1]  Yong Shen,et al.  Comparison of vertebroplasty and kyphoplasty in the treatment of osteoporotic vertebral compression fractures with intravertebral clefts , 2014, European Journal of Orthopaedic Surgery & Traumatology.

[2]  A. V. van Erkel,et al.  Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. , 2011, The spine journal : official journal of the North American Spine Society.

[3]  J. Yeom,et al.  The Volumetric Analysis of Cement in Vertebroplasty: Relationship With Clinical Outcome and Complications , 2011, Spine.

[4]  I. Cha,et al.  Analysis of adjacent fracture after percutaneous vertebroplasty: does intradiscal cement leakage really increase the risk of adjacent vertebral fracture? , 2011, Skeletal Radiology.

[5]  Wen-Jer Chen,et al.  Impact of Cement Leakage Into Disks on the Development of Adjacent Vertebral Compression Fractures , 2010, Journal of spinal disorders & techniques.

[6]  F. Al-Ali,et al.  Vertebroplasty: What Is Important and What Is Not , 2009, American Journal of Neuroradiology.

[7]  D. Gelb,et al.  Neurologic Deficit Following Percutaneous Vertebral Stabilization , 2007, Spine.

[8]  D. Kallmes,et al.  The effects of cement volume on clinical outcomes of percutaneous vertebroplasty. , 2006, AJNR. American journal of neuroradiology.

[9]  S. Ferguson,et al.  Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies , 2006, Spine.

[10]  Gero Miesenböck,et al.  New technologies , 2005, Current Opinion in Neurobiology.

[11]  M. Aebi,et al.  A comprehensive classification of thoracic and lumbar injuries , 2005, European Spine Journal.

[12]  R. Schmidt,et al.  Cement leakage during vertebroplasty: an underestimated problem? , 2005, European Spine Journal.

[13]  K. Ahrar,et al.  Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty. , 2004, AJR. American journal of roentgenology.

[14]  J. Mathis,et al.  Vertebroplasty versus kyphoplasty: a comparison and contrast. , 2004, AJNR. American journal of neuroradiology.

[15]  T. Franz,et al.  Kyphoplasty for treatment of osteoporotic vertebral fractures: a prospective non-randomized study , 2004, European Spine Journal.

[16]  S. Chung,et al.  Intravertebral vacuum phenomenon in osteoporotic compression fracture: report of 67 cases with quantitative evaluation of intravertebral instability. , 2004, Journal of neurosurgery.

[17]  C. K. Lee,et al.  Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. , 2003, The Journal of bone and joint surgery. British volume.

[18]  D. Kallmes,et al.  Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures. , 2002, AJNR. American journal of neuroradiology.

[19]  Joon-ki Kang,et al.  Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. , 2002, Journal of neurosurgery.

[20]  I. Lieberman,et al.  Initial Outcome and Efficacy of “Kyphoplasty” in the Treatment of Painful Osteoporotic Vertebral Compression Fractures , 2001, Spine.

[21]  Mark A. Reiley,et al.  New Technologies in Spine: Kyphoplasty and Vertebroplasty for the Treatment of Painful Osteoporotic Compression Fractures , 2001, Spine.

[22]  H. Genant,et al.  Treatment of Painful Osteoporotic Vertebral Fractures with Percutaneous Vertebroplasty or Kyphoplasty , 2001, Osteoporosis International.

[23]  Michael K. Landi,et al.  Vertebroplasty: techniques to avoid complications. , 2001, The spine journal : official journal of the North American Spine Society.