High-frequency synthetic ultrasound array incorporating an actuator

Ultrasound imaging at frequencies above 20 MHz relies almost exclusively on single-element transducers. IN order to apply array technology at these frequencies, several practical problems must be solved, including spatial scale and fabrication limitations, low device capacitance, and lack of a hardware beamformer. One method of circumventing these problems is to combine an array, an actuator, and a synthetic aperture software beamformer. The array can use relatively wide elements spaced on a coarse pitch. The actuator is used to move the array in short steps (less than the element pitch), and pulse-echo data is acquired at intermediate sample positions. The synthetic aperture beamformer reconstructs the image from the pulse-echo data. A 50 MHz example is analyzed in detail. Estimates of signal-to-noise reveal performance comparable to a standard phased array; furthermore, the actuated array requires half the number of elements, the elements are 8x wider, and only one channel is required. Simulated three-dimensional point spread functions demonstrate side lobe levels approaching - 40dB and main beam widths of 50 to 100 microns. A 50 MHz piezo-composite array design has been tested which displays experimental bandwidth of 70% while maintaining high sensitivity. Individual composite sub-elements are 18 microns wide. Once this array is integrated with a suitable actuator, it is anticipated that a tractable method of imaging with high frequency arrays will result.

[1]  H. Ermert,et al.  Ultrasound synthetic aperture imaging: monostatic approach , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  M. O'Donnell,et al.  Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[4]  M. O'Donnell,et al.  Catheter arrays: can intravascular ultrasound make a difference in managing coronary artery disease , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[5]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  D. E. Dick,et al.  Ultrasonic Synthetic Aperture Imaging , 1977 .

[7]  G. R. Lockwood,et al.  Laser micromachined high frequency ultrasonic arrays , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[8]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Timothy A. Ritter,et al.  High-frequency transducer arrays for medical imaging , 2000, Medical Imaging.

[10]  M. O’Donnell,et al.  Experimental studies on an efficient catheter array imaging system. , 1995, Ultrasonic imaging.

[11]  K. Kushida,et al.  A 100-MHz ultrasonic transducer array using ZnO thin films , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  D.N. Stephens,et al.  Miniaturized circular array [for intravascular ultrasound] , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[13]  Peter Grant,et al.  A Digital Synthetic Focus Acoustic Imaging System for NDE , 1978 .

[14]  R. N. Thomson Transverse and longitudinal resolution of the synthetic aperture focusing technique , 1984 .

[15]  G. Trahey,et al.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  G. Kino Acoustic waves : devices, imaging, and analog signal processing , 1987 .