Advantages of using microfabricated extracellular electrodes for in vitro neuronal recording

We describe fabrication methods and the characterisation and use of extracellalar microelectrode arrays for the detection of action potentials from neurons in culture. The 100 μm2 platinised gold microelectrodes in the 64 electrode array detect the external current which flows during an action potential with S:N ratios of up to 500:1, giving a maximum recorded signal of several millivolts. The performance of these electrodes is enhanced if good sealing of the cells over the electrodes is obtained and further enhanced if the electrodes and the cells lie in a deep groove in the substratum. The electrodes can be used for both recording and stimulation of activity in cultured neurons and for recording from multiple sites on a single cell. The use of such electrodes to obtain recordings from invertebrate neurons is described. The particular advantages of these electrodes, their long term stability, non‐invasive nature, high packing density, and utility in stimulation, are demonstrated. © 1995 Wiley‐Liss, Inc.

[1]  F. Clarac,et al.  Direct evidence for presynaptic inhibitory mechanisms in crayfish sensory afferents. , 1992, Journal of neurophysiology.

[2]  A. Bulloch,et al.  Identification, characterisation and in vitro reconstruction of an interneuronal network of the snail Helisoma trivolvis. , 1993, The Journal of experimental biology.

[3]  J. Pine Recording action potentials from cultured neurons with extracellular microcircuit electrodes , 1980, Journal of Neuroscience Methods.

[4]  A. Bulloch,et al.  In vitro reconstruction of the respiratory central pattern generator of the mollusk Lymnaea. , 1990, Science.

[5]  P. Connolly,et al.  Simultaneous multisite recordings and stimulation of single isolated leech neurons using planar extracellular electrode arrays , 1994, Journal of Neuroscience Methods.

[6]  Y. Jimbo,et al.  Electrical stimulation and recording from cultured neurons using a planar electrode array , 1992 .

[7]  W. N. Ross,et al.  Simultaneous optical measurements of electrical activity from multiple sites on processes of cultured neurons. , 1981, Proceedings of the National Academy of Sciences of the United States of America.

[8]  P Connolly,et al.  Growth cone guidance and neuron morphology on micropatterned laminin surfaces. , 1993, Journal of cell science.

[9]  P. Fromherz,et al.  A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate field-effect transistor. , 1991, Science.

[10]  David J. Edell,et al.  A Peripheral Nerve Information Transducer for Amputees: Long-Term Multichannel Recordings from Rabbit Peripheral Nerves , 1986, IEEE Transactions on Biomedical Engineering.

[11]  C. Wilkinson,et al.  An extracellular microelectrode array for monitoring electrogenic cells in culture. , 1990, Biosensors & bioelectronics.

[12]  I. Tasaki EXCITATION OF SINGLE NERVE FIBER BY ACTION CURRENT FROM ANOTHER SINGLE FIBER , 1950 .

[13]  C. Wilkinson,et al.  Topographical control of cell behaviour: II. Multiple grooved substrata. , 1990, Development.

[14]  D. Baylor,et al.  Synchronous bursts of action potentials in ganglion cells of the developing mammalian retina. , 1991, Science.

[15]  David W. Tank,et al.  Sealing cultured invertebrate neurons to embedded dish electrodes facilitates long-term stimulation and recording , 1989, Journal of Neuroscience Methods.

[16]  W. Winlow,et al.  The distribution of three wide-acting synaptic inputs to identified neurons in the isolated brain of , 1981 .

[17]  I. Levitan,et al.  Concanavalin A alters synaptic specificity between cultured Aplysia neurons. , 1987, Science.

[18]  S. Kater,et al.  Neurite outgrowth in molluscan organ and cell cultures: the role of conditioning factor(s) , 1981, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[19]  W. Regehr,et al.  A long-term in vitro silicon-based microelectrode-neuron connection , 1988, IEEE Transactions on Biomedical Engineering.

[20]  Guenter W. Gross,et al.  Recording of spontaneous activity with photoetched microelectrode surfaces from mouse spinal neurons in culture , 1982, Journal of Neuroscience Methods.

[21]  Julian A. T. Dow,et al.  Single cell mobility and adhesion monitoring using extracellular electrodes , 1991 .

[22]  G. Gross,et al.  Multielectrode analysis of coordinated, multisite, rhythmic bursting in cultured CNS monolayer networks , 1986, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[23]  Matthias Chiquet,et al.  Neurite outgrowth and synapse formation by identified leech neurones in culture. , 1987, The Journal of experimental biology.

[24]  M. Chiquet,et al.  Attachment of Con A or extracellular matrix initiates rapid sprouting by cultured leech neurons. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[25]  P. Fromherz,et al.  Cable properties of a straight neurite of a leech neuron probed by a voltage-sensitive dye. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[26]  Patricia Connolly,et al.  Finite-element analysis applied to extracellular microelectrode design , 1991 .

[27]  A. S. G. Curtis,et al.  THE MECHANISM OF ADHESION OF CELLS TO GLASS , 1964, The Journal of cell biology.

[28]  W. N. Ross,et al.  Optical measurements of potential changes in axons and processes of neurons of a barnacle ganglion , 1984, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[29]  P. Fromherz,et al.  Cable properties of arborized Retzius cells of the leech in culture as probed by a voltage-sensitive dye. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[30]  R. Miledi,et al.  Motor units in the rat diaphragm , 1958, The Journal of physiology.

[31]  R. Pickard,et al.  Printed circuit microelectrodes and their application to honeybee brain. , 1976, The Journal of experimental biology.