FE Analysis of Contact between Residual Limb and Socket during Simulation of Amputee Motion
暂无分享,去创建一个
[1] Vincent G. Duffy. Digital Human Modeling and Perception-Based Safety Design , 2007, ERCIM News.
[2] M. Eder,et al. Patient-Specific Optimization of Prosthetic Socket Construction and Fabrication Using Innovative Manufacturing Processes : A Project in Progress , 2010 .
[3] A. Mak,et al. In vivo friction properties of human skin , 1999, Prosthetics and orthotics international.
[4] M Zhang,et al. Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.
[5] Caterina Rizzi,et al. Knowledge-based system for guided modelling of sockets for lower limb prostheses , 2010 .
[6] J C H Goh,et al. Development of an integrated CAD-FEA process for below-knee prosthetic sockets. , 2005, Clinical biomechanics.
[7] Daniel Thalmann,et al. Handbook of Virtual Humans , 2004 .
[8] M. Zhang,et al. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. , 2000, Medical engineering & physics.
[9] Aft Mak,et al. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface , 2001 .
[10] Jung Hwa Hong. Effect of hip moment on socket interface pressure during stance phase gait of transfemoral amputee , 2006 .
[11] W. Lee,et al. Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. , 2004, Journal of biomechanics.
[12] D. Thalmann,et al. Handbook of Virtual Humans: Magnenat-Thalma/Handbook of Virtual Humans , 2006 .
[13] V. C. Roberts,et al. Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis. , 1998, Medical engineering & physics.
[14] Ming Zhang,et al. Using computational simulation to aid in the prediction of socket fit: a preliminary study. , 2007, Medical engineering & physics.
[15] A F Mak,et al. State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review. , 2001, Journal of rehabilitation research and development.
[16] D S Childress,et al. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. , 1996, Journal of rehabilitation research and development.
[17] V. C. Roberts,et al. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. , 1995, Medical engineering & physics.
[18] P Sewell,et al. Developments in the transtibial prosthetic socket fitting process: A review of past and present research , 2000, Prosthetics and orthotics international.
[19] J. Geertzen,et al. Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses , 2005, Prosthetics and orthotics international.
[20] D. Childress,et al. Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. , 1993, Journal of rehabilitation research and development.
[21] Chih-Han Chang,et al. A proposal for the pre‐evaluation protocol of below‐knee socket design - integration pain tolerance with finite element analysis , 2003 .
[22] Xiaohong Jia,et al. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.
[23] Caterina Rizzi,et al. Physically Based Modelling and Simulation to Innovate Socket Design , 2011 .
[24] Xiaohong Jia,et al. A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. , 2005, Clinical biomechanics.
[25] Caterina Rizzi,et al. A digital patient for computer-aided prosthesis design , 2013, Interface Focus.