FE Analysis of Contact between Residual Limb and Socket during Simulation of Amputee Motion

The contact pressure at the socket–residual limb interface is the most important parameter to evaluate comfort of leg prosthesis. Experimental works analyzed this parameter for typical postures and during walking of an amputee; but experimental tests require a real prototype of the socket equipped with transducers. To optimize socket design, this work presents a virtual approach based on a digital avatar of the patient wearing lower limb prosthesis. Our approach considers the integration of two different types of simulation: the first one concerns the multi-body gait analysis, the second one the pressure evaluation at the socket–residual limb interface with FE analyses. The paper describes the model used, the simulation tools adopted and their integration. Finally the case study related to patient walking on flat floor is described.

[1]  Vincent G. Duffy Digital Human Modeling and Perception-Based Safety Design , 2007, ERCIM News.

[2]  M. Eder,et al.  Patient-Specific Optimization of Prosthetic Socket Construction and Fabrication Using Innovative Manufacturing Processes : A Project in Progress , 2010 .

[3]  A. Mak,et al.  In vivo friction properties of human skin , 1999, Prosthetics and orthotics international.

[4]  M Zhang,et al.  Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.

[5]  Caterina Rizzi,et al.  Knowledge-based system for guided modelling of sockets for lower limb prostheses , 2010 .

[6]  J C H Goh,et al.  Development of an integrated CAD-FEA process for below-knee prosthetic sockets. , 2005, Clinical biomechanics.

[7]  Daniel Thalmann,et al.  Handbook of Virtual Humans , 2004 .

[8]  M. Zhang,et al.  Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket. , 2000, Medical engineering & physics.

[9]  Aft Mak,et al.  State-of-the-art research in lower-limb prosthetic biomechanics-socket interface , 2001 .

[10]  Jung Hwa Hong Effect of hip moment on socket interface pressure during stance phase gait of transfemoral amputee , 2006 .

[11]  W. Lee,et al.  Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. , 2004, Journal of biomechanics.

[12]  D. Thalmann,et al.  Handbook of Virtual Humans: Magnenat-Thalma/Handbook of Virtual Humans , 2006 .

[13]  V. C. Roberts,et al.  Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis. , 1998, Medical engineering & physics.

[14]  Ming Zhang,et al.  Using computational simulation to aid in the prediction of socket fit: a preliminary study. , 2007, Medical engineering & physics.

[15]  A F Mak,et al.  State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review. , 2001, Journal of rehabilitation research and development.

[16]  D S Childress,et al.  Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. , 1996, Journal of rehabilitation research and development.

[17]  V. C. Roberts,et al.  Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. , 1995, Medical engineering & physics.

[18]  P Sewell,et al.  Developments in the transtibial prosthetic socket fitting process: A review of past and present research , 2000, Prosthetics and orthotics international.

[19]  J. Geertzen,et al.  Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses , 2005, Prosthetics and orthotics international.

[20]  D. Childress,et al.  Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. , 1993, Journal of rehabilitation research and development.

[21]  Chih-Han Chang,et al.  A proposal for the pre‐evaluation protocol of below‐knee socket design - integration pain tolerance with finite element analysis , 2003 .

[22]  Xiaohong Jia,et al.  Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.

[23]  Caterina Rizzi,et al.  Physically Based Modelling and Simulation to Innovate Socket Design , 2011 .

[24]  Xiaohong Jia,et al.  A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. , 2005, Clinical biomechanics.

[25]  Caterina Rizzi,et al.  A digital patient for computer-aided prosthesis design , 2013, Interface Focus.