Optimal combination of FLAIR and T2‐weighted MRI for improved lesion contrast in multiple sclerosis

Postacquisition combination of three‐dimensional T2‐weighted (T2w) and fluid‐attenuated inversion recovery (FLAIR) images can improve the visualization of brain lesions in multiple sclerosis (MS). However, an optimal way to combine these images has not been described so far. The main objective of this study is to investigate an optimal combination of T2w and FLAIR to improve the conspicuity of MS lesions.

[1]  E. Kahana,et al.  Multiple sclerosis: geoepidemiology, genetics and the environment. , 2010, Autoimmunity reviews.

[2]  K. Scheffler A pictorial description of steady-states in rapid magnetic resonance imaging , 1999 .

[3]  Christian Enzinger,et al.  Relaxation time mapping in multiple sclerosis , 2011, Expert review of neurotherapeutics.

[4]  M. Horsfield,et al.  Ultra-high-field MR imaging in multiple sclerosis , 2013, Journal of Neurology, Neurosurgery & Psychiatry.

[5]  Frederik Barkhof,et al.  Intracortical lesions in multiple sclerosis: improved detection with 3D double inversion-recovery MR imaging. , 2005, Radiology.

[6]  F. Barkhof,et al.  Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla , 2010, European Radiology.

[7]  Hellmut Merkle,et al.  Chronic multiple sclerosis lesions: characterization with high-field-strength MR imaging. , 2012, Radiology.

[8]  R Stollberger,et al.  A comparison of magnetization transfer ratio, magnetization transfer rate, and the native relaxation time of water protons related to relapsing-remitting multiple sclerosis. , 2000, AJNR. American journal of neuroradiology.

[9]  D. Okada,et al.  Digital Image Processing for Medical Applications , 2009 .

[10]  Richard Kijowski,et al.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo , 2008, Magnetic resonance in medicine.

[11]  Stephen M. Pizer,et al.  Fundamental properties of medical image perception , 1991, Journal of Digital Imaging.

[12]  O. Ciccarelli,et al.  MS cortical lesions on double inversion recovery MRI , 2012, Neurology.

[13]  D. MacManus,et al.  Magnetic resonance imaging in clinically isolated lesions of the brain stem. , 1986, Journal of neurology, neurosurgery, and psychiatry.

[14]  A. Traboulsee,et al.  FLAIR2: A Combination of FLAIR and T2 for Improved MS Lesion Detection , 2016, American Journal of Neuroradiology.

[15]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[16]  Chiara Romualdi,et al.  Detection of cortical inflammatory lesions by double inversion recovery magnetic resonance imaging in patients with multiple sclerosis. , 2007, Archives of neurology.

[17]  Brian B. Avants,et al.  N4ITK: Improved N3 Bias Correction , 2010, IEEE Transactions on Medical Imaging.

[18]  P. Narayana,et al.  Improved Identification of Intracortical Lesions in Multiple Sclerosis with Phase-Sensitive Inversion Recovery in Combination with Fast Double Inversion Recovery MR Imaging , 2007, American Journal of Neuroradiology.

[19]  G. Barker,et al.  Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis , 2000, Journal of the Neurological Sciences.

[20]  T W Redpath,et al.  Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter. , 1994, The British journal of radiology.

[21]  Jeffrey A. Cohen,et al.  Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteria , 2011, Annals of neurology.

[22]  R. Zivadinov,et al.  3D FLAIRED: 3D fluid attenuated inversion recovery for enhanced detection of lesions in multiple sclerosis , 2012, Magnetic resonance in medicine.

[23]  O. Ciccarelli,et al.  Consensus recommendations for MS cortical lesion scoring using double inversion recovery MRI , 2011, Neurology.

[24]  M Rovaris,et al.  Cortical/subcortical disease burden and cognitive impairment in patients with multiple sclerosis. , 2000, AJNR. American journal of neuroradiology.

[25]  K. Scheffler,et al.  Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS) , 2003, Magnetic resonance in medicine.

[26]  Amol S Pednekar,et al.  Automated patient‐specific optimization of three‐dimensional double‐inversion recovery magnetic resonance imaging , 2016, Magnetic resonance in medicine.

[27]  Pascal Sati,et al.  FLAIR*: a combined MR contrast technique for visualizing white matter lesions and parenchymal veins. , 2012, Radiology.

[28]  Refaat E. Gabr,et al.  Online brain tissue classification in multiple sclerosis using a scanner-integrated image analysis pipeline , 2015, 2014 International Conference on Computer Vision Theory and Applications (VISAPP).