Membrane separation in flow injection systems

A critical review of membranes for on-line separations in flow-through dialysers is given. Historical perspectives are briefly outlined. The fundamental aspects of dialysis as the selective separation of species through a semi-permeable membrane are discussed. Work done on theoretical principles by a number of authors is described and a simplified model is given. The basic components, locations thereof and the influence of various parameters on dialysis efficiency are highlighted. The value of dialysis as sampling preparation system for chromatography and reactor systems is outlined and the suitability of dialyser/flow injection systems in dilution, preconcentration and multicomponent analysis is evaluated. The review is concluded with a brief look at the use of dialysis in proteinligand binding studies and microdialysis.

[1]  Miguel Valcárcel,et al.  Integration of separation and detection in continuous-flow systems , 1991 .

[2]  W. Pardridge,et al.  Determination of in vivo steady-state unbound drug concentration in the brain interstitial fluid by microdialysis , 1992 .

[3]  M. Koupparis,et al.  Drug dissolution studies in milk using the automated flow injection serial dynamic dialysis technique , 1986 .

[4]  M. J. Hunter,et al.  Interactions of Neutral Amino Acids with Human Serum Albumin and γ-Globulin1 , 1955 .

[5]  M. Koupparis,et al.  An automated flow injection-serial dynamic dialysis technique for drug-protein binding studies , 1986 .

[6]  Elo Harald Hansen,et al.  Flow injection analysis : Part X. theory, techniques and trends , 1978 .

[7]  P. Kissinger,et al.  Bioanalytical sample preparation using microdialysis and ultrafiltration capillaries , 1992 .

[8]  Fang Zhao-lun,et al.  On-line separation and preconcentration in flow injection analysis , 1988 .

[9]  W. Dreyer,et al.  Measurement of protein-binding phenomena by gel filtration. , 1962, Biochimica et biophysica acta.

[10]  D. Guttman,et al.  Novel method for studying protein binding. , 1968, Journal of pharmaceutical sciences.

[11]  W J Kolff,et al.  The Artificial Kidney: a dialyser with a great area , 2009 .

[12]  J. Cox,et al.  Separation of mixtures of cations by Donnan dialysis , 1981 .

[13]  P. Kissinger,et al.  In vivo sampling using loop microdialysis probes coupled to a liquid chromatograph. , 1992, Journal of chromatography.

[14]  L. Gorton,et al.  Flow injection analysis for glucose and urea with enzyme reactors and on-line dialysis , 1981 .

[15]  J. F. van Staden,et al.  Three component flow injection analysis with on-line dialysis. Simultaneous determination of free calcium, total calcium and total chloride in milk by flow injection analysis and on-line dialysis , 1990 .

[16]  J. Veuthey,et al.  Spectrophotometric determination of ethanol in blood using a flow-injection system with an immobilized enzyme (alcohol dehydrogenase) reactor coupled to an on-line dialyser , 1990 .

[17]  K. Rasmussen,et al.  Automated high-performance liquid chromatography of iopentol in human plasma and whole blood using on-line dialysis as sample preparation. , 1992, Journal of chromatography.

[18]  G. Christian,et al.  Serum lithium analysis by coated wire lithium ion selective electrodes in a flow injection analysis dialysis system. , 1986, Analytical chemistry.

[19]  J. J. Abel,et al.  ON THE REMOVAL OF DIFFUSIBLE SUBSTANCES FROM THE CIRCULATING BLOOD OF LIVING ANIMALS BY DIALYSIS II. SOME CONSTITUENTS OF THE BLOOD , 1914 .

[20]  Mark E. Meyerhoff,et al.  Flow Injection Determination of Ammonia-N Using Polymer Membrane Electrode-based Gas Sensing System , 1981 .

[21]  W. V. D. Linden,et al.  MEMBRANE SEPARATION IN FLOW INJECTION ANALYSIS Gas Diffusion , 1983 .

[22]  J. van der Greef,et al.  Automated analysis of mitomycin C in body fluids by high-performance liquid chromatography with on-line sample pre-treatment. , 1987, Journal of chromatography.

[23]  M. Tena,et al.  Solid interfaces as analytical problem solvers in flow injection analysis. , 1993, Talanta.

[24]  L. Gorton,et al.  Potentiometric determination of glucose by enzymatic oxidation in a flow system , 1979 .

[25]  I M Klotz,et al.  PHYSICOCHEMICAL ASPECTS OF DRUG‐PROTEIN INTERACTIONS: A GENERAL PERSPECTIVE , 1973, Annals of the New York Academy of Sciences.

[26]  M C Meyer,et al.  The binding of drugs by plasma proteins. , 1968, Journal of pharmaceutical sciences.

[27]  G. Johansson,et al.  Optimization of flow-through cells for dialysis and other membrane separations in flow-injection analysis using a laminar flow model , 1989 .

[28]  J. Cox,et al.  Metal speciation by Donnan dialysis , 1984 .

[29]  B. Karlberg,et al.  Flow Injection Analysis: A Practical Guide , 1989 .

[30]  J. Cooper,et al.  Automated sequential process for preparing samples for analysis by high-performance liquid chromatography. , 1987, Journal of chromatography.

[31]  L. Brand,et al.  Evidence for binding of rose bengal and anilinonaphthalenesulfonates at the active site regions of liver alcohol dehydrogenase. , 1967, Biochemistry.

[32]  D. Scott,et al.  Microdialysis-perfusion sampling for the investigation of phenol metabolism. , 1989, Journal of pharmaceutical and biomedical analysis.

[33]  F. Krug,et al.  Merging zones in flow injection analysis : Part 4. Simultaneous spectrophotometric determination of total nitrogen and phosphorus in plant material , 1980 .

[34]  J. Ruzicka,et al.  Gradient techniques in flow injection analysis , 1982 .

[35]  M. Valcárcel,et al.  Analytical potential of continuous precipitation in flow injection-atomic absorption configurations , 1987 .

[36]  J. Cox,et al.  Selection of the receiver electrolyte for the Donnan dialysis enrichment of cations , 1984 .

[37]  J. Burguera,et al.  Flow injection spectrophotometry followed by atomic Absorption spectrometry for the determination of iron(II) and total iron , 1984 .

[38]  P. Stockwell Automatic Chemical Analysis , 1996 .

[39]  K. Rasmussen,et al.  Automated analysis of oxolinic acid and flumequine in salmon whole blood and plasma using dialysis combined with trace enrichment as on-line sample preparation for high-performance liquid chromatography. , 1991, Journal of chromatography.

[40]  I Zini,et al.  Microdialysis and luminescent probe: analytical and clinical aspects. , 1991, Biosensors & bioelectronics.

[41]  J. Koropchak,et al.  Flow-injection Donnan dialysis preconcentration of cations for flame atomic absorption spectrophotometry , 1989 .

[42]  François Qian,et al.  THE USE of ON-LINE DIALYSIS WITH HPLC FOR THE AUTOMATED PREPARATION AND ANALYSIS OF COMPLEX SAMPLES , 1991 .

[43]  Jacobus F. van Staden,et al.  Flow-Injection Analysis of Chloride in Milk with a Dialyzer and a Coated Tubular Inorganic Chloride-Selective Electrode , 1986 .

[44]  J. Möller,et al.  Application of flow injection techniques for the analysis of inorganic anions , 1985 .

[45]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[46]  P. Worsfold,et al.  Introduction to flow injection analysis , 1983 .

[47]  M. Smyth,et al.  Monitoring excitatory amino acid release in vivo by microdialysis with capillary electrophoresis-electrochemistry. , 1992, Journal of chromatography.

[48]  S. Kolev,et al.  Laminar dispersion in parallel plate sections of flow systems used in analytical chemistry and chemical engineering , 1991 .

[49]  H. Stein Studies of binding by macromolecules. A new dialysis technique for obtaining quantitative data. , 1965, Analytical biochemistry.

[50]  M. Gisin,et al.  Hydrodynamically limited precision of gradient techniques in flow injection analysis , 1986 .

[51]  T. Ikeda,et al.  Serum Alkaline Phosphatase Assay Using a Dialysis Membrane-Covered Glassy-Carbon Electrode , 1992 .

[52]  B. Petersson Evaluation of an Enzymatic Method For Determination of Glucose In Whole Blood Using Flow Injection Analysis With Detection By Chemiluminescence , 1989 .

[53]  L. Skeggs An automatic method for colorimetric analysis. , 1957, American journal of clinical pathology.

[54]  B. Reis,et al.  Simultaneous determination of nitrate and nitrite by flow injection analysis , 1980 .

[55]  G. Brown,et al.  An improved technique for continuous in vivo analysis of glucose. , 1966, Clinica chimica acta; international journal of clinical chemistry.

[56]  M. Meyerhoff,et al.  Membrane-dialzer injection loop for enhancing the selectivity of anion-responsive liquid-membrane electrodes in flow systems. Part 1. A sensing system for NOx and nitrite , 1986 .

[57]  J. Cox,et al.  Voltammetric determination of trace quantities of nitrate in an anion exchange membrane isolated cell , 1975 .

[58]  A. O. Rangel,et al.  Determination of metallic cations in wines by flow injection analysis , 1990 .

[59]  J. Cox,et al.  Tubular flow Donnan dialysis , 1980 .

[60]  L. A. Beightol,et al.  Automated solid-phase extraction and high-performance liquid chromatographic determination of ranitidine from urine, plasma and peritoneal dialysate. , 1987, Journal of chromatography.

[61]  Robert L. Wilson,et al.  Enrichment of nickel and cobalt in natural hard water by Donnan dialysis , 1981 .

[62]  J. Cooper,et al.  Automated sequential trace enrichment of dialysates and robotics. A technique for the preparation of biological samples prior to high-performance liquid chromatography. , 1988, Journal of chromatography.

[63]  Josef Stein Table errata: Handbook of mathematical functions with formulas, graphs, and mathematical tables (Nat. Bur. Standards, Washington, D.C., 1964) edited by Milton Abramowitz and Irene A. Stegun , 1970 .

[64]  Gary D. Christian,et al.  Split zone flow-injection analysis: an approach to automated dilutions , 1989 .

[65]  M. Valcárcel,et al.  Indirect atomic absorption determination of chloride by continuous precipitation of silver chloride in a flow injection system , 1987 .

[66]  J. B. Justice,et al.  Rapid sampling and determination of extracellular dopamine in vivo. , 1987, Analytical chemistry.

[67]  J. F. Staden,et al.  Experimental evaluation of commercially available semi-permeable membranes for use with parallel-plate dialysers in flow injection systems , 1990 .

[68]  E. Da̧bek-Złotorzyńska,et al.  Rapid, On-Line Preconcentration, Matrix Normalization, and Signal Enhancement for Flame Atomic Absorption via Tubular Donnan Dialysis , 1987 .

[69]  Z. Fang Flow Injection Separation and Preconcentration , 1993 .

[70]  J. G. Mcelligott,et al.  Physical and chemical considerations in the in vitro calibration of microdialysis probes for biogenic amine neurotransmitters and metabolites , 1990, Journal of Neuroscience Methods.

[71]  L. Hansen,et al.  Automatic dialyzing-injection system for liquid chromatography of ions and small molecules , 1982 .

[72]  G. S. Deshmukh,et al.  Bromometric determination of vanadium (V) by hydrazine , 1956 .

[73]  A. E. Russell,et al.  An automated continuous-flow dynamic dialysis technique for investigating protein-ligand binding. , 1982, Analytical biochemistry.

[74]  N. Kasthurikrishnan,et al.  Flow injection Donnan dialysis preconcentration of trace metal cations for inductively coupled plasma atomic emission spectrometry , 1993 .

[75]  L. Murphy,et al.  A dialysis electrode for glycerol , 1993 .

[76]  U. Brinkman,et al.  On-line combination of dialysis and column-switching liquid chromatography as a fully automated sample preparation technique for biological samples. Determination of nitrofuran residues in edible products. , 1990, Journal of chromatography.

[77]  J. Greef,et al.  Bioanalysis of the peptide de-enkephalin-γ-endorphin , 1990 .

[78]  D. A. Hall,et al.  A new method for the continuous monitoring of blood glucose by measurement of dissolved oxygen. , 1965, Clinical chemistry.

[79]  S. Kolev,et al.  Influence of the main parameters of a parallel-plate dialyser under laminar flow conditions , 1992 .

[80]  J. Cooper,et al.  Totally automated liquid-chromatographic assay for cortisol and associated glucocorticoids in serum, with use of ASTED sample preparation. , 1988, Clinical chemistry.

[81]  J. Korf,et al.  An enzyme-reactor for electrochemical monitoring of choline and acetylcholine: applications in high-performance liquid chromatography, brain tissue, microdialysis and cerebrospinal fluid. , 1992, Analytical biochemistry.

[82]  B. Bernhardsson,et al.  Solute transfer in on-line analytical flow-through dialyzers , 1985 .

[83]  G. Johansson,et al.  Galactose determination in an automated flow-injection system containing enzyme reactors and an on-line dialyzer , 1985 .

[84]  J. Cooper,et al.  Automatic preparation of human serum samples for analysis of the drug enoximone and its sulphoxide metabolite using high-performance liquid chromatography. , 1986, Journal of chromatography.

[85]  J. Toei An Improved Zone Sampling Method for Flow Injection Analysis , 1988 .

[86]  H. K. Lonsdale,et al.  The growth of membrane technology , 1982 .

[87]  J. F. Staden Simultaneous flow injection analysis for two components with a double on-line dialyser , 1993 .

[88]  D. Cooney,et al.  Mass transfer in parallel-plate dialyzers—A conjugated boundary value problem , 1974 .

[89]  Martyn G. Boutelle,et al.  The dialysis electrode—a new method for in vivo monitoring , 1992 .

[90]  J. Ruzicka,et al.  Flow injection analysis : Part V. Simultaneous determination of nitrogen and phosphorus in acid digests of plant material with a single spectrophotometer , 1976 .

[91]  K. Rasmussen,et al.  Automated on-Line Dialysis and Column-Switching HPLC Determination of Flumequine and Oxolinic Acid in Fish Liver , 1990 .

[92]  M. Meyerhoff,et al.  Membrane-dialyzer injection loop for enhancing the selectivity of anion-responsive liquid-membrane electrodes in flow systems Part 2. A selective sensing system for salicylate , 1986 .

[93]  K. Stewart,et al.  Exponential dilution chambers for scale expansion in flow injection analysis , 1982 .

[94]  J. Dinunzio,et al.  Donnan dialysis preconcentration for ion chromatography , 1983 .

[95]  Huang Ting-Chia,et al.  Selective separation of nickel and copper from a complexing solution by a cation-exchange membrane , 1988 .

[96]  J. Cox,et al.  Separation of platinum group metal ions by Donnan dialysis , 1985 .

[97]  J. H. Wolf,et al.  The Extracellular Concentration of the Anti‐epileptic Drug Valproate in the Rat Brain as Determined with Microdialysis and an Automated HPLC Procedure , 1991, The Journal of pharmacy and pharmacology.

[98]  G. Christian,et al.  Cascade system for rapid on-line dilutions in flow-injection analysis. , 1989, Talanta.

[99]  Elo Harald Hansen,et al.  Flow injection analysis, 2nd edn. : Wiley, Chichester, 1988 ISBN (0-471-81355-9) xx+498 pp. Price £65.00 , 1989 .

[100]  M. Koupparis,et al.  An automated flow-injection serial dynamic dialysis technique for drug-protein binding studies , 1986 .

[101]  W W Holl,et al.  THE AUTOMATION OF SINGLE TABLET ASSAYS * , 1965, Annals of the New York Academy of Sciences.

[102]  Miguel Valcárcel Cases,et al.  Flow-injection analysis : principles and applications , 1987 .

[103]  Irene A. Stegun,et al.  Handbook of Mathematical Functions. , 1966 .

[104]  T. Lynch,et al.  Speciation of metals in solution by flow injection analysis. Part 1. Sequential spectrophotometric and atomic-absorption detectors , 1984 .

[105]  J. F. Staden,et al.  Direct determination of calcium in milk on a non-segmented continuous-flow system , 1979 .

[106]  U. Sundqvist A new microdialysis unit for flow injection analysis , 1988 .

[107]  B. Rietz,et al.  Flow injection analysis: Part VIII. Determination of glucose in blood serum with glucose dehydrogenase , 1977 .

[108]  Bo Olsson,et al.  Amperometric Determination of Galactose, Lactose and Dihydroxyacetone Using Galactose Oxidase in a Flow Injection System with Immobilized Enzyme Reactors and On-Line Dialysis , 1985 .

[109]  J. Korf,et al.  Direct coupling of intracerebral dialysis with flow injection analysis based on enzymatic/fluorescence detection of lactic acid , 1988 .

[110]  U. Ungerstedt,et al.  Simultaneous determination of lactate, pyruvate, and ascorbate in microdialysis samples from rat brain, blood, fat, and muscle using high-performance liquid chromatography. , 1989, Journal of pharmacological methods.

[111]  Shahida B. Niazi,et al.  Binding of butylated hydroxyanisole to human albumin using a novel dynamic method. , 1978, Journal of pharmaceutical sciences.

[112]  J. Ruzicka,et al.  Flow injection analysis : Part VI. The determination of phosphate and chloride in blood serum by dialysis and sample dilution , 1976 .

[113]  L. Fellows,et al.  Enzyme packed bed system for the on-line measurement of glucose, glutamate, and lactate in brain microdialysate. , 1992, Analytical chemistry.

[114]  P. Worsfold,et al.  A comparison of spectrophotometric and chemiluminescence methods for the determination of blood glucose by flow injection analysis , 1984 .

[115]  Klotz Im,et al.  The Binding of Organic Ions by Proteins1 , 1946 .

[116]  Bo Mattiasson,et al.  Evaluation of a dialysis probe for continuous sampling in fermentors and in complex media , 1984 .

[117]  D. C. Turnell,et al.  A concurrent process for the automatic preparation of biological samples combined with high pressure liquid chromatographic analysis , 1986, The Journal of automatic chemistry.

[118]  L. Luzzi,et al.  Structure relationship for binding of sulfonamides and penicillins to bovine serum albumin by fluorescence probe technique. , 1974, Journal of pharmaceutical sciences.

[119]  T. Silhavy,et al.  On the significance of the retention of ligand by protein. , 1975, Proceedings of the National Academy of Sciences of the United States of America.

[120]  P. Kissinger,et al.  Capillary ultrafiltration: in vivo sampling probes for small molecules. , 1992, Analytical chemistry.

[121]  J. Tyson Flow injection atomic spectrometry , 1991 .

[122]  J. Cox,et al.  Donnan dialysis enrichment of cations , 1977 .

[123]  J. Toffaletti,et al.  Spectrophotometric micro method for measurement of dialyzable calcium by use of cresolphthalein complexone and continuous-flow analysis. , 1980, Clinical chemistry.

[124]  M. Smyth,et al.  Capillary electrophoresis—electrochemistry of microdialysis samples for pharmacokinetic studies , 1992 .

[125]  C. A. Marsden,et al.  Measurement of neurotransmitter release in vivo , 1984 .

[126]  Y. Michotte,et al.  The use of microdialysis for the determination of plasma protein binding of drugs. , 1992, Journal of pharmaceutical and biomedical analysis.

[127]  M. Valcárcel,et al.  Coupling of continuous separation techniques with unsegmented flow systems , 1992 .

[128]  M. Mascini,et al.  Electrochemical biosensors for extracorporeal measurements. , 1991, Biochemical Society Transactions.

[129]  A. Townshend,et al.  Determination of glucose in blood by flow injection analysis and an immobilized glucose oxidase column , 1985 .

[130]  J. Slanina,et al.  A computer-controlled multichannel continuous flow analysis system applied to the measurement of nitrate, chloride and ammonium ions in small samples of rain water , 1980 .

[131]  R. M. Wallace Concentration and Separation of Ions by Donnan Membrane Equilibrium , 1967 .

[132]  J. Cox,et al.  Donnan dialysis matrix normalization for the voltammetric determination of metal ions , 1980 .

[133]  L. Craig,et al.  DIALYSIS STUDIES. III. MODIFICATION OF PORE SIZE AND SHAPE IN CELLOPHANE MEMBRANES , 1961 .

[134]  M. Aguilar,et al.  Removal of interferences in the spectrophotometric determination of cyanide by dialysis using flow injection analysis , 1988 .

[135]  Miguel Valcárcel,et al.  Continuous separation techniques in flow injection analysis , 1987 .

[136]  J. F. Staden Simultaneous flow-injection analysis of three components with on-line dialyzers in series. Determination of sodium, potassium and chloride in blood serum. , 1991 .

[137]  F. Vérillon,et al.  Couplage de la dialyse avec la chromatographie en phase liquide pour l'analyse automatique d'échantillons complexes , 1991 .

[138]  J. F. Staden,et al.  Simultaneous determination of sodium, potassium, magnesium and calcium in surface, ground and domestic water by flow-injection analysis , 1980 .

[139]  W. Frenzel Membrane based gas sampling and analysis coupled to continuous flow systems , 1992 .

[140]  J. Alvin,et al.  CHARACTERIZATION OF DRUG‐PROTEIN INTERACTIONS BY CLASSIC METHODS * , 1973, Annals of the New York Academy of Sciences.

[141]  W. Traag,et al.  Fully automated column-switching HPLC determination of aflatoxin M1 in milk using dialysis as sample preparation , 1989 .

[142]  J. Cox,et al.  High sample convection Donnan dialysis , 1983 .

[143]  G. Scatchard,et al.  THE ATTRACTIONS OF PROTEINS FOR SMALL MOLECULES AND IONS , 1949 .

[144]  F. Karush Heterogeneity of the Binding Sites of Bovine Serum Albumin1 , 1950 .

[145]  G. Christian,et al.  Universal sandwich membrane cell and detector for optical flow injection analysis , 1992 .

[146]  J. F. Staden,et al.  Simultaneous determination of total and free calcium in milk by flow injection , 1990 .

[147]  M. Gisin,et al.  Extensive flow-injection dilution for in-line sample pretreatment , 1988 .

[148]  L. Chia,et al.  Simultaneous measurement of serotonin, catecholamines and their metabolites in cat and human plasma by in vitro microdialysis-microbore high-performance liquid chromatography with amperometric detection. , 1992, Journal of chromatography.

[149]  D. Cooney,et al.  Analyses of mass transfer in hemodialyzers for laminar blood flow and homogeneous dialysate , 1974 .

[150]  J. H. Wolf,et al.  Automated analysis procedure for valproic acid in blood, serum and brain dialysate by high-performance liquid chromatography with bromomethylmethoxycoumarin as fluorescent label. , 1989, Journal of chromatography.

[151]  Craig E. Lunte,et al.  Pharmacokinetic studies of aspirin in rats using in vivo microdialysis sampling , 1991 .

[152]  K. Pyrzyńska Membrane method for preconcentrating and separating gold complexes from aqueous solutions containing other platinum group metals , 1991 .

[153]  U. Ungerstedt,et al.  A comparison between three methods for estimation of extracellular concentrations of exogenous and endogenous compounds by microdialysis. , 1991, Journal of pharmacological methods.

[154]  Jiří Koryta ION-Selective Electrodes , 1986 .

[155]  J. Cooper,et al.  Automated preparation of biological samples prior to high pressure liquid chromatography: Part I- The use of dialysis for deproteinizing serum for amino-acid analysis , 1985, The Journal of automatic chemistry.

[156]  S. Colowick,et al.  Binding of diffusible molecules by macromolecules: rapid measurement by rate of dialysis. , 1969, The Journal of biological chemistry.

[157]  G. J. Jong,et al.  Liquid chromatographic determination of azidothymidine in human plasma using on-line dialysis and preconcentration on a silver(I)-thiol stationary phase , 1990 .

[158]  N. Tanaka,et al.  Donnan dialysis preconcentrator for the ion chromatography of anions , 1985 .

[159]  G. Tucker,et al.  The Second Ionization of 5,5-Disubstituted Derivatives of Barbituric Acid1 , 1955 .

[160]  D. Berggren speciation of Cadmium(II) Using Donnan Dialysis and Differential-Pulse Anodic Stripping Voltammetry in a Flow-Injection System , 1990 .

[161]  L. Gorton,et al.  A study of the use of microdialysis probes as a sampling unit in on-line bioprocess monitoring in conjunction with column liquid chromatography , 1993 .

[162]  U. Ungerstedt,et al.  Microdialysis in the study of extracellular levels of amino acids in the rat brain. , 1986, Acta physiologica Scandinavica.

[163]  S. Kolev,et al.  Analysis of transient laminar mass transfer in a parallel-plate dialyser , 1992 .

[164]  J. Dinunzio,et al.  Preconcentration of some transition and rare-earth elements by Donnan dialysis. , 1983, Talanta.

[165]  J. B. Justice,et al.  Sampling considerations for on-line microbore liquid chromatography of brain dialysate. , 1986, Analytical chemistry.

[166]  J. F. Staden Automated prevalve dilution in flow-injection analysis , 1985 .

[167]  B. Westerink MONITORING MOLECULES IN THE CONSCIOUS BRAIN BY MICRODIALYSIS , 1992 .

[168]  J. Cooper,et al.  Automated preparation of biological samples prior to high pressure liquid chromatography: Part II- The combined use of dialysis and trace enrichment for analysing biological material , 1985, The Journal of automatic chemistry.

[169]  J. F. Staden Automated dilution in flow injection analysis with double on-line dialysis. A system for the determination of chloride in industrial effluents and plating bath solutions , 1991 .

[170]  F. Krug,et al.  Zone-sampling processes in flow injection analysis , 1981 .

[171]  J. F. Staden Simultaneous flow-injection analysis for two components with on-line dialysis and gas diffusion in series. Determination of chloride and ammonia nitrogen in industrial effluent water , 1992 .

[172]  J. L. Hudson,et al.  Data analysis of chaotic chemical reactions , 1992 .