Glaucoma Diagnostic Ability of the New Circumpapillary Retinal Nerve Fiber Layer Thickness Analysis Based on Bruch's Membrane Opening.

PURPOSE To compare the diagnostic ability of the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), with the conventional circumpapillary RNFL thickness measurement centered on the optic disc. METHODS In 75 eyes with primary open-angle glaucoma (POAG) and 71 healthy control eyes, circumpapillary RNFL thickness was measured with SD-OCT, first by centering the scan circle on the optic disc (RNFLDi), and then on the BMO (RNFLBMO). Difference between the topographic profiles of RNFLDi and RNFLBMO was compared and factors influencing any discrepancies between methods were investigated. Glaucoma diagnostic abilities of each method were assessed using the areas under receiver operating characteristic curve (AUCs). RESULTS Axial length did not differ between POAG and healthy eyes. A longer axial length and larger width of externally oblique border tissue (BT) associated with tilted optic disc were the two major factors influencing discrepancies between RNFLBMO and RNFLDi (both P < 0.001). Compared with RNFLBMO, RNFLDi tended to result in a thinner nasal RNFL in eyes with externally oblique BT, while RNFLBMO and RNFLDi were comparable in eyes without externally oblique BT. The glaucoma diagnostic capabilities were generally comparable, but RNFLBMO was superior to RNFLDi in eyes having a larger width (>250 μm) of externally oblique BT (AUC = 0.933 vs. 0.843, respectively, P = 0.027). CONCLUSIONS The new circumpapillary RNFL scanning algorithm centered on BMO may provide a more reliable RNFL profile in eyes with tilted optic discs, with a largely comparable glaucoma diagnostic ability to the conventional algorithm.

[1]  Y. Hwang,et al.  Characteristics of Peripapillary Retinal Nerve Fiber Layer Thickness in Eyes With Myopic Optic Disc Tilt and Rotation , 2012, Journal of glaucoma.

[2]  Y. Yoo,et al.  Correct calculation circle location of optical coherence tomography in measuring retinal nerve fiber layer thickness in eyes with myopic tilted discs. , 2011, Investigative ophthalmology & visual science.

[3]  G. Wollstein,et al.  Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma. , 2005, Archives of ophthalmology.

[4]  C. Cheung,et al.  Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling study , 2009, Eye.

[5]  Eun Ji Lee,et al.  Differentiation of parapapillary atrophy using spectral-domain optical coherence tomography. , 2013, Ophthalmology.

[6]  Robert N. Weinreb,et al.  Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. , 2010, Ophthalmology.

[7]  E A Swanson,et al.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. , 1995, Archives of ophthalmology.

[8]  F. Medeiros,et al.  A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma. , 2006, Investigative ophthalmology & visual science.

[9]  Ki Ho Park,et al.  Structure-function relationships in normal and glaucomatous eyes determined by time- and spectral-domain optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[10]  J. Fujimoto,et al.  Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. , 1996, Ophthalmology.

[11]  Johannes F de Boer,et al.  Analysis of Normal Retinal Nerve Fiber Layer Thickness by Age, Sex, and Race Using Spectral Domain Optical Coherence Tomography , 2011, Journal of glaucoma.

[12]  B. Chauhan,et al.  From clinical examination of the optic disc to clinical assessment of the optic nerve head: a paradigm change. , 2013, American journal of ophthalmology.

[13]  S L Zeger,et al.  Regression analysis for correlated data. , 1993, Annual review of public health.

[14]  J. Funk,et al.  Repeatability of nerve fiber layer thickness measurements in patients with glaucoma and without glaucoma using spectral-domain and time-domain OCT , 2012, Graefe's Archive for Clinical and Experimental Ophthalmology.

[15]  Mauricio E Pons,et al.  Heidelberg retina tomography and optical coherence tomography in normal, ocular-hypertensive, and glaucomatous eyes. , 1999, Ophthalmology.

[16]  M S Pepe,et al.  Three approaches to regression analysis of receiver operating characteristic curves for continuous test results. , 1998, Biometrics.

[17]  Hiroshi Ishikawa,et al.  Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability. , 2008, Investigative ophthalmology & visual science.

[18]  M. Nicolela,et al.  Optic disc margin anatomy in patients with glaucoma and normal controls with spectral domain optical coherence tomography. , 2012, Ophthalmology.

[19]  Robert N Weinreb,et al.  Evaluation of retinal nerve fiber layer progression in glaucoma: a comparison between spectral-domain and time-domain optical coherence tomography. , 2011, Ophthalmology.

[20]  Seung Woo Hong,et al.  Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[21]  T-W Kim,et al.  Peripapillary retinal nerve fibre layer thickness profile in subjects with myopia measured using the Stratus optical coherence tomography , 2009, British Journal of Ophthalmology.

[22]  J. Hanley,et al.  Statistical analysis of correlated data using generalized estimating equations: an orientation. , 2003, American journal of epidemiology.

[23]  J. Jonas,et al.  Optic disc shape, corneal astigmatism, and amblyopia. , 1997, Ophthalmology.

[24]  M. Nicolela,et al.  Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter. , 2013, Ophthalmology.

[25]  Gary Longton,et al.  Accommodating Covariates in Receiver Operating Characteristic Analysis , 2009 .

[26]  R. Weinreb,et al.  Optic disc change with incipient myopia of childhood. , 2012, Ophthalmology.

[27]  A. Turpin,et al.  Enhanced structure-function relationship in glaucoma with an anatomically and geometrically accurate neuroretinal rim measurement. , 2014, Investigative ophthalmology & visual science.

[28]  Robert N Weinreb,et al.  Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes. , 2003, Ophthalmology.

[29]  N. Strouthidis,et al.  Comparison of clinical and spectral domain optical coherence tomography optic disc margin anatomy. , 2009, Investigative ophthalmology & visual science.

[30]  Y. Hwang,et al.  Ability of cirrus high-definition spectral-domain optical coherence tomography clock-hour, deviation, and thickness maps in detecting photographic retinal nerve fiber layer abnormalities. , 2013, Ophthalmology.

[31]  Thomas A. Severini,et al.  Extended Generalized Estimating Equations for Clustered Data , 1998 .

[32]  J. Jonas,et al.  Interobserver variability of optic disk variables measured by confocal scanning laser tomography. , 2001, American journal of ophthalmology.

[33]  H. Shin,et al.  The effect of myopic optic disc tilt on measurement of spectral-domain optical coherence tomography parameters , 2014, British Journal of Ophthalmology.

[34]  Dong Myung Kim,et al.  Diagnostic Ability of Spectral-domain Versus Time-domain Optical Coherence Tomography in Preperimetric Glaucoma , 2014, Journal of glaucoma.

[35]  L. Zangwill,et al.  Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography. , 2000, Ophthalmology.

[36]  N. Strouthidis,et al.  Comparison of clinical and three-dimensional histomorphometric optic disc margin anatomy. , 2009, Investigative ophthalmology & visual science.

[37]  Eun Ji Lee,et al.  Microstructure of β-zone parapapillary atrophy and rate of retinal nerve fiber layer thinning in primary open-angle glaucoma. , 2014, Ophthalmology.

[38]  C. Cheung,et al.  Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. , 2006, Investigative ophthalmology & visual science.

[39]  F. Medeiros,et al.  Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma. , 2011, Investigative ophthalmology & visual science.