Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma–mass spectrometry and atomic absorption spectrometry

Abstract A biomonitoring method for the determination of Pb, Cd, and Hg at background levels in whole blood by inductively coupled plasma-mass spectrometry is described. While this method was optimized for assessing Pb, Cd and Hg at environmental levels, it also proved suitable for assessing concentrations associated with occupational exposure. The method requires as little as 200 μl of blood that is diluted 1 + 49 for direct analysis in the inductively coupled plasma-mass spectrometer. Method performance is compared to well-established AAS methods. Initial method validation was accomplished using National Institute of Standards and Technology (NIST) Standard Reference Material 966, Toxic Metals in Bovine Blood. Method detection limits (3s) are 0.05 μg dl − 1 for Pb, 0.09 μg l − 1 for Cd; and 0.17 μg l − 1 for Hg. Repeatability ranged from 1.4% to 2.8% for Pb; 3% to 10% for Cd; and 2.6% to 8.8% for Hg. In contrast, AAS method detection limits were 1 μg dl − 1 , 0.54 μg l − 1 , and 0.6 μg l − 1 , for Pb, Cd, and Hg, respectively. Further performance assessments were conducted over a 2-year period via participation in four international External Quality Assessment Schemes (EQAS) operated specifically for toxic metals in blood. This includes schemes operated by (a) the New York State Department of Health's Wadsworth Center, Albany, NY, USA (b) L′Institut National de Sante Publique du Quebec, Centre de Toxicologie du Quebec, Canada, (c) Friedrich-Alexander University, Erlangen, Germany, and (d) the University of Surrey, Guildford, UK Trace Elements scheme. The EQAS data reflect analytical performance for blind samples analyzed independently by both inductively coupled plasma-mass spectrometry and AAS methods.

[1]  Thomas P. Moyer,et al.  The determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry , 1999 .

[2]  D. Paschal,et al.  Determination of total and inorganic mercury in whole blood by on-line digestion with flow injection , 1998 .

[3]  B. Sturman Comment on “Determination of mercury in potable water by ICP-MS using gold as a stabilising agent” (J. Allibone, E. Fatemian and P. J. Walker, J. Anal. At. Spectrom., 1999, 14, 235) , 2000 .

[4]  R. Ritsema,et al.  Practical and quality-control aspects of multi-element analysis with quadrupole ICP–MS with special attention to urine and whole blood , 2004, Analytical and bioanalytical chemistry.

[5]  P. Parsons,et al.  A rapid Zeeman graphite furnace atomic absorption spectrometric method for the determination of lead in blood , 1993 .

[6]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[7]  J. Baasner,et al.  On-line microwave sample pretreatment for the determination of mercury in blood by flow injection cold vapor atomic absorption spectrometry. , 1993, Talanta.

[8]  E. Sabbioni,et al.  Trace element reference values in tissues from inhabitants of the European Union. X. A study of 13 elements in blood and urine of a United Kingdom population. , 1998, The Science of the total environment.

[9]  John Marshall,et al.  Atomic Spectrometry Update. Clinical and biological materials, foods and beverages , 1987 .

[10]  P. Parsons,et al.  Determination of total mercury in whole blood by flow injection cold vapor atomic absorption spectrometry with room temperature digestion using tetramethylammonium hydroxide , 2004 .

[11]  K. Neubauer,et al.  An overview of clinical applications by inductively coupled plasma mass spectrometry , 1998 .

[12]  D. Altman,et al.  Comparing methods of measurement: why plotting difference against standard method is misleading , 1995, The Lancet.

[13]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[14]  I. Bergdahl,et al.  Trace element levels in whole blood and serum from Swedish adolescents. , 2002, The Science of the total environment.

[15]  Jenna Mandel-Ricci,et al.  Study Design and Participation Rates of the New York City Health and Nutrition Examination Survey, 2004 , 2006, Preventing chronic disease.

[16]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[17]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[18]  M. Stoeppler,et al.  Contributions to automated trace analysis , 1980 .

[19]  J O Westgard,et al.  A multi-rule Shewhart chart for quality control in clinical chemistry. , 1981, Clinical chemistry.

[20]  Robert L. Jones,et al.  Inductively coupled plasma mass spectrometry to measure multiple toxic elements in urine in NHANES 1999-2000 , 2005 .

[21]  Peter Heitland,et al.  Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS , 2004 .

[22]  T. Moyer,et al.  Routine clinical determination of lead, arsenic, cadmium, and thallium in urine and whole blood by inductively coupled plasma mass spectrometry , 1996 .

[23]  P. Walker,et al.  Determination of mercury in potable water by ICP-MS using gold as a stabilising agent , 1999 .

[24]  Staffan Skerfving,et al.  Trace elements in blood and serum of Swedish adolescents: relation to gender, age, residential area, and socioeconomic status. , 2002, Environmental research.

[25]  E W Gunter,et al.  Determination of lead in blood using electrothermal atomisation atomic absorption spectrometry with a L'vov platform and matrix modifier. , 1987, The Analyst.