High-performance computer-aided optimization of viscous dampers for improving the seismic performance of a tall building

Abstract Using fluid viscous dampers (FVDs) has been demonstrated to be an effective method to improve seismic performance of new and existing buildings. In engineering applications, designs of these dampers mainly rely on trial and error, which is repetitive and labor intensive. To improve on this tedious manual process, it is beneficial to explore more formal and automated approaches that rely on recent advances in software applications for nonlinear dynamic analysis, performance-based evaluation, workflow management and the computational power of high-performance, parallel processing computers. The optimization design procedure follows the framework of Performance Based Earthquake Engineering (PBEE) and uses an automatic tool that incorporates an optimization engine and structural analysis software: Open System for Earthquake Engineering Simulation (OpenSEES). An existing 35-story steel moment frame is selected as a case-study building for verification of this procedure. The goal of the retrofit design of FVDs is to improve the building's seismic behavior to avoid collapse under a Level 2, basic safety earthquake event (BSE-2E). An objective function of building's total loss under a BSE-2E event is used and its optimal damper patterns will be proposed. The efficiency of the optimization procedure will be demonstrated and compared with the manual procedure.

[1]  Stephen A. Mahin,et al.  Seismic assessment of existing tall buildings: A case study of a 35-story steel building with pre-Northridge connection , 2017 .

[2]  Mahendra P. Singh,et al.  Optimal placement of dampers for passive response control , 2002 .

[3]  Izuru Takewaki,et al.  Output frequency response function based design of additional nonlinear viscous dampers for vibration control of multi-degree-of-freedom systems , 2013 .

[4]  Tomaso Trombetti,et al.  ADDED VISCOUS DAMPERS IN SHEAR-TYPE STRUCTURES: THE EFFECTIVENESS OF MASS PROPORTIONAL DAMPING , 2004 .

[5]  Martin S. Williams,et al.  A Comparison of Viscous Damper Placement Methods for Improving Seismic Building Design , 2012 .

[6]  Izuru Takewaki,et al.  Nonlinear optimal oil damper design in seismically controlled multi-story building frame , 2013 .

[7]  Stephen J. Wright,et al.  Numerical Optimization , 2018, Fundamental Statistical Inference.

[8]  Michael H. Scott,et al.  Nonlinear Finite-Element Analysis Software Architecture Using Object Composition , 2010, J. Comput. Civ. Eng..

[9]  Oren Lavan,et al.  Fully stressed design of passive controllers in framed structures for seismic loadings , 2006 .

[10]  Izuru Takewaki Building Control with Passive Dampers: Optimal Performance-based Design for Earthquakes , 2009 .

[11]  Stephen A. Mahin,et al.  Seismic retrofit of a high-rise steel moment-resisting frame using fluid viscous dampers , 2017 .

[12]  Gary F. Dargush,et al.  Optimal seismic design of moment‐resisting steel frames with hysteretic passive devices , 2009 .

[13]  Gary F. Dargush,et al.  Multi-Objective Evolutionary Seismic Design with Passive Energy Dissipation Systems , 2009 .

[14]  Kohei Fujita,et al.  Optimal placement of viscoelastic dampers and supporting members under variable critical excitations , 2010 .

[15]  Izuru Takewaki,et al.  Optimal damper placement for minimum transfer functions , 1997 .

[16]  H. Kit Miyamoto,et al.  Design of Steel Pyramid Using Seismic Dampers , 1997 .

[17]  Kohei Fujita,et al.  Importance of interstory velocity on optimal along-height allocation of viscous oil dampers in super high-rise buildings , 2013 .

[18]  N. Null Seismic Evaluation and Retrofit of Existing Buildings , 2014 .

[19]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[20]  T. T. Soong,et al.  Passive Energy Dissipation Systems in Structural Engineering , 1997 .

[21]  Norman A. Abrahamson,et al.  Spectral damping scaling factors for shallow crustal earthquakes in active tectonic regions , 2012 .

[22]  T. T. Soong,et al.  Efficiency of a simple approach to damper allocation in MDOF structures , 2002 .

[23]  Michael C. Constantinou,et al.  EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF SEISMIC RETROFIT OF STRUCTURES WITH SUPPLEMENTAL DAMPING: PART 1 - FLUID VISCOUS DAMPING DEVICES , 1995 .

[24]  Michael C. Constantinou,et al.  Experimental & Analytical Investigation of Seismic Response of Structures With Supplemental Fluid Viscous Dampers , 1992 .