High-performance computer-aided optimization of viscous dampers for improving the seismic performance of a tall building
暂无分享,去创建一个
[1] Stephen A. Mahin,et al. Seismic assessment of existing tall buildings: A case study of a 35-story steel building with pre-Northridge connection , 2017 .
[2] Mahendra P. Singh,et al. Optimal placement of dampers for passive response control , 2002 .
[3] Izuru Takewaki,et al. Output frequency response function based design of additional nonlinear viscous dampers for vibration control of multi-degree-of-freedom systems , 2013 .
[4] Tomaso Trombetti,et al. ADDED VISCOUS DAMPERS IN SHEAR-TYPE STRUCTURES: THE EFFECTIVENESS OF MASS PROPORTIONAL DAMPING , 2004 .
[5] Martin S. Williams,et al. A Comparison of Viscous Damper Placement Methods for Improving Seismic Building Design , 2012 .
[6] Izuru Takewaki,et al. Nonlinear optimal oil damper design in seismically controlled multi-story building frame , 2013 .
[7] Stephen J. Wright,et al. Numerical Optimization , 2018, Fundamental Statistical Inference.
[8] Michael H. Scott,et al. Nonlinear Finite-Element Analysis Software Architecture Using Object Composition , 2010, J. Comput. Civ. Eng..
[9] Oren Lavan,et al. Fully stressed design of passive controllers in framed structures for seismic loadings , 2006 .
[10] Izuru Takewaki. Building Control with Passive Dampers: Optimal Performance-based Design for Earthquakes , 2009 .
[11] Stephen A. Mahin,et al. Seismic retrofit of a high-rise steel moment-resisting frame using fluid viscous dampers , 2017 .
[12] Gary F. Dargush,et al. Optimal seismic design of moment‐resisting steel frames with hysteretic passive devices , 2009 .
[13] Gary F. Dargush,et al. Multi-Objective Evolutionary Seismic Design with Passive Energy Dissipation Systems , 2009 .
[14] Kohei Fujita,et al. Optimal placement of viscoelastic dampers and supporting members under variable critical excitations , 2010 .
[15] Izuru Takewaki,et al. Optimal damper placement for minimum transfer functions , 1997 .
[16] H. Kit Miyamoto,et al. Design of Steel Pyramid Using Seismic Dampers , 1997 .
[17] Kohei Fujita,et al. Importance of interstory velocity on optimal along-height allocation of viscous oil dampers in super high-rise buildings , 2013 .
[18] N. Null. Seismic Evaluation and Retrofit of Existing Buildings , 2014 .
[19] Andrei M. Reinhorn,et al. Design of Supplemental Dampers for Control of Structures , 1996 .
[20] T. T. Soong,et al. Passive Energy Dissipation Systems in Structural Engineering , 1997 .
[21] Norman A. Abrahamson,et al. Spectral damping scaling factors for shallow crustal earthquakes in active tectonic regions , 2012 .
[22] T. T. Soong,et al. Efficiency of a simple approach to damper allocation in MDOF structures , 2002 .
[23] Michael C. Constantinou,et al. EXPERIMENTAL AND ANALYTICAL INVESTIGATION OF SEISMIC RETROFIT OF STRUCTURES WITH SUPPLEMENTAL DAMPING: PART 1 - FLUID VISCOUS DAMPING DEVICES , 1995 .
[24] Michael C. Constantinou,et al. Experimental & Analytical Investigation of Seismic Response of Structures With Supplemental Fluid Viscous Dampers , 1992 .