High pressure polymer electrolyte water electrolysis: Test bench development and electrochemical analysis

Abstract A test bench for a polymer electrolyte water electrolysis (PEWE) cell for high pressure operation of up to 100 bar in differential and balanced pressure mode is described. Important aspects referring to the design, safety and operability of the test bench and the design of a small scale electrolysis cell are described. The electrolyzer cell comprises a special compression mechanism which allows accommodating porous transport layers of different thickness and setting of the compression pressure independent of the clamping pressure. In order to analyze the electrochemical results with respect to the overpotentials, a power source with integrated high frequency resistance (HFR) as well as electrochemical impedance spectroscopy (EIS) measurement capabilities is implemented. The versatility of the test environment is demonstrated by comparing the DC, HFR and EIS data as a function of operating pressure, temperature (up to 70 °C) and current density (up to 4 A/cm2). With respect to pressurized operation of PEWE cells, only the differential pressure mode (hydrogen pressurized) shows the expected isothermal compression behavior, for balanced pressure operation a different characteristic is observed.

[1]  Sally M. Benson,et al.  The energetic implications of curtailing versus storing solar- and wind-generated electricity , 2013 .

[2]  D. Tromans Temperature and pressure dependent solubility of oxygen in water: a thermodynamic analysis , 1998 .

[3]  D. Stolten,et al.  Gas Permeation through Nafion. Part 1: Measurements , 2015 .

[4]  R. Noble,et al.  Role of conditioning on water uptake and hydraulic permeability of Nafion® membranes , 2006 .

[5]  Pierre Millet,et al.  Description and characterization of an electrochemical hydrogen compressor/concentrator based on solid polymer electrolyte technology , 2011 .

[6]  F. Büchi,et al.  In-situ resistance measurements of Nafion® 117 membranes in polymer electrolyte fuel cells , 1996 .

[7]  Menno Koeman,et al.  Invited) Electrochemical Hydrogen Compression , 2014 .

[8]  S. V. Grigoriev,et al.  Chapter 2 – Water Electrolysis Technologies , 2013 .

[9]  T. Morawietz,et al.  Durable Membrane Electrode Assemblies for Proton Exchange Membrane Electrolyzer Systems Operating at High Current Densities , 2016 .

[10]  K. Onda,et al.  Performance analysis of polymer-electrolyte water electrolysis cell at a small-unit test cell and performance prediction of large stacked cell , 2002 .

[11]  James B. Robinson,et al.  In situ diagnostic techniques for characterisation of polymer electrolyte membrane water electrolysers – Flow visualisation and electrochemical impedance spectroscopy , 2014 .

[12]  Claude Etievant,et al.  Hydrogen safety aspects related to high-pressure polymer electrolyte membrane water electrolysis , 2009 .

[13]  R. Wiebe,et al.  The Solubility of Hydrogen in Water at 0, 50, 75 and 100° from 25 to 1000 Atmospheres , 1933 .

[14]  Claude Etievant,et al.  GenHyPEM: A research program on PEM water electrolysis supported by the European Commission , 2009 .

[15]  H. Takenaka,et al.  Properties of Nafion membranes under PEM water electrolysis conditions , 2011 .

[16]  N. Briguglio,et al.  An electrochemical study of a PEM stack for water electrolysis , 2012 .

[17]  S. A. Grigor’ev,et al.  Electrolysis of Water in a System with a Solid Polymer Electrolyte at Elevated Pressure , 2001 .

[18]  Pablo Sanchis,et al.  Hydrogen Production From Water Electrolysis: Current Status and Future Trends , 2012, Proceedings of the IEEE.

[19]  Philipp Dietrich,et al.  Towards re-electrification of hydrogen obtained from the power-to-gas process by highly efficient H2/O2 polymer electrolyte fuel cells , 2014 .

[20]  Gareth Hinds,et al.  In situ characterisation of PEM water electrolysers using a novel reference electrode. , 2015 .

[21]  F. Büchi,et al.  Cell Performance Determining Parameters in High Pressure Water Electrolysis , 2016 .

[22]  S. Grigoriev,et al.  High-pressure PEM water electrolysis and corresponding safety issues , 2011 .

[23]  Everett B. Anderson,et al.  Research Advances towards Low Cost, High Efficiency PEM Electrolysis , 2010, ECS Transactions.

[24]  Pierre Millet,et al.  Electrochemical characterization of Polymer Electrolyte Membrane Water Electrolysis Cells , 2014 .

[25]  H. Gasteiger,et al.  New insights into the electrochemical hydrogen oxidation and evolution reaction mechanism , 2014 .

[26]  V. Bolobov Mechanism of Self-Ignition of Titanium Alloys in Oxygen , 2002 .

[27]  I. Barin Thermochemical data of pure substances , 1989 .

[28]  L. Gubler,et al.  Radiation Grafted Membranes for Fuel Cells: Strategies to Compete With PFSA Membranes , 2013 .

[29]  Massimo Santarelli,et al.  Analysis of water transport in a high pressure PEM electrolyzer , 2010 .

[30]  P. M. Diéguez,et al.  Renewable hydrogen technologies : production, purification, storage, applications and safety , 2013 .

[31]  K. Sundmacher,et al.  Optimal configuration and pressure levels of electrolyzer plants in context of power-to-gas applications , 2016 .

[32]  石川 博之,et al.  Development of 70 MPa Differential-pressure Water Electrolysis Stack , 2016 .

[33]  Tetsuo Sakai,et al.  Gas Permeation Properties of Solid Polymer Electrolyte (SPE) Membranes , 1985 .