Prophylactic Vertebroplasty May Reduce the Risk of Adjacent Intact Vertebra From Fatigue Injury: An Ex Vivo Biomechanical Study

Study Design. In vitro biomechanical study using human spine specimens. Objective. To find the biomechanical consequences of prophylactic vertebroplasty post fatigue loading. Summary of Background Data. Percutaneous vertebroplasty man be an effective treatment for osteoporotic vertebral compression fracture. One frequently observed complication post surgery is the adjacent vertebral failure (AVF). The prophylactic vertebroplasty was proposed to prevent the AVF. The vertebroplasty is, nevertheless, an invasive intervention. More scientific proves are needed for the application of this surgery on a still intact vertebra. Methods. Fourteen 5-level fresh human cadaveric thoracic motion segments were divided into standard and prophylactic group. Both ends of the specimen were mounted, leaving the center 3 vertebrae free. The lower level of free vertebrae was artificially injured and cement augmented. The center level vertebra of standard group remained intact and nonaugmented. The center level vertebra of prophylactic group also remained intact, but augmented with bone cement. The specimen was applied with a 2-hour, 5-Hz, 630-N (mean) compressive fatigue loading. Impulse test and CT scanning were conducted both before and after fatigue loading to find the variance of strain compliance of cortical shell and height of vertebral body. Results. The strain compliance of cortical shell is generally not statistically significantly affected by the fatigue loading, cement augmentation and vertebral level (All P > 0.05). The only exception is that the cortical strain compliance of augmented vertebrae tentatively decreased post fatigue loading (P = 0.012 for tensile strain compliance, and P = 0.049 for compressive strain compliance). The height loss of intact vertebra adjacent to a 2-level augmented (or intact-augmented) vertebra is significantly lower than the one adjacent to a 1-level augmented (or injury-augmented) vertebra (P = 0.014). For an osteoporotic vertebra, neither cortical strain compliance nor vertebral height loss is connected with bone mineral density (all P > 0.05). Conclusion. The strain compliance of cortical shell is generally not a sensitive indicator to predict risk of fatigue injury if the fatigue loading is mild. The prophylactic augmentation strengthens the osteoporotic vertebrae, decreases the progression of vertebral height loss, reduces the anterior body shift, and hence protects the adjacent intact vertebra from elevated flexion bending. It can be cautiously suggested that if the vertebra is osteoporotic and adjacent level is located at pivot or lordotic level of spinal column, the prophylactic augmentation may be an option to prevent the AVF.

[1]  J. Graham,et al.  Effect of Bone Density on Vertebral Strength and Stiffness After Percutaneous Vertebroplasty , 2007, Spine.

[2]  E. Schneider,et al.  Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement , 2007, European Spine Journal.

[3]  J. Nemes,et al.  Load shift of the intervertebral disc after a vertebroplasty: a finite-element study , 2003, European Spine Journal.

[4]  A. Cappozzo,et al.  Compressive loads in the lumbar vertebral column during normal level walking , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  Joshua A Hirsch,et al.  Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. , 2003, Radiology.

[6]  Hans-Joachim Wilke,et al.  Biomechanical Evaluation of Vertebroplasty and Kyphoplasty With Polymethyl Methacrylate or Calcium Phosphate Cement Under Cyclic Loading , 2006, Spine.

[7]  S. Glassman,et al.  A Human Cadaver Model for Determination of Pathologic Fracture Threshold Resulting From Tumorous Destruction of the Vertebral Body , 1998, Spine.

[8]  Lisa A Ferrara,et al.  Distribution of anterior cortical shear strain after a thoracic wedge compression fracture. , 2004, The spine journal : official journal of the North American Spine Society.

[9]  Jaw-Lin Wang,et al.  The shock attenuation properties of straight standing knee joints using different shock absorbers and energy inputs , 2003 .

[10]  Mi Jung Kim,et al.  Vertebroplasty Versus Kyphoplasty: Biomechanical Behavior Under Repetitive Loading Conditions , 2006, Spine.

[11]  I. Lieberman,et al.  The Biomechanics of 1, 2, and 3 Levels of Vertebral Augmentation With Polymethylmethacrylate in Multilevel Spinal Segments , 2006, Spine.

[12]  Courtney W. Brown,et al.  Osteoporotic Spinal Deformity: A Biomechanical Rationale for the Clinical Consequences and Treatment of Vertebral Body Compression Fractures , 2004, Journal of spinal disorders & techniques.

[13]  S. Belkoff,et al.  The effect of monomer-to-powder ratio on the material properties of cranioplastic. , 1999, Bone.

[14]  M. Aebi,et al.  A comprehensive classification of thoracic and lumbar injuries , 2005, European Spine Journal.

[15]  G. Bergmann,et al.  Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty , 2006, European Spine Journal.

[16]  N. Haas,et al.  Percutaneous balloon kyphoplasty in the treatment of pathological vertebral body fracture and deformity in multiple myeloma: a one-year follow-up , 2006, Acta radiologica.

[17]  L. Nolte,et al.  Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. , 2002, The Journal of bone and joint surgery. British volume.

[18]  J. Nemes,et al.  Biomechanical explanation of adjacent fractures following vertebroplasty. , 2003, Radiology.

[19]  J. Torner,et al.  Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model. , 2001, Journal of neurosurgery.

[20]  L. Nolte,et al.  The Effect of Cement Augmentation on the Load Transfer in an Osteoporotic Functional Spinal Unit: Finite-Element Analysis , 2003, Spine.

[21]  K. Sun,et al.  Biomechanics of Prophylactic Vertebral Reinforcement , 2004, Spine.

[22]  B. Bai,et al.  The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. , 1999, Spine.

[23]  M. Bostrom,et al.  Future Directions: Augmentation of Osteoporotic Vertebral Bodies , 1997 .

[24]  I. Lieberman,et al.  Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine. , 2005, The spine journal : official journal of the North American Spine Society.

[25]  Y. van der Graaf,et al.  The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty. , 2006, Journal of vascular and interventional radiology : JVIR.

[26]  M. Hongo,et al.  Surface strain distribution on thoracic and lumbar vertebrae under axial compression. The role in burst fractures. , 1999, Spine.

[27]  J. Laredo,et al.  Complications of percutaneous vertebroplasty and their prevention , 2004, Skeletal Radiology.

[28]  Jaw-Lin Wang,et al.  Rest Cannot Always Recover the Dynamic Properties of Fatigue-Loaded Intervertebral Disc , 2008, Spine.

[29]  I. Lieberman,et al.  Adjacent Level Load Transfer Following Vertebral Augmentation in the Cadaveric Spine , 2006, Spine.

[30]  Thomas R Oxland,et al.  Thoracolumbar spine mechanics contrasted under compression and shear loading , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[31]  Ruth K Wilcox,et al.  A Biomechanical Investigation of Vertebroplasty in Osteoporotic Compression Fractures and in Prophylactic Vertebral Reinforcement , 2007, Spine.

[32]  Andrew S. Lee,et al.  Risk Factors of New Compression Fractures in Adjacent Vertebrae after Percutaneous Vertebroplasty , 2007, Asian spine journal.

[33]  D. Kallmes,et al.  New fractures after vertebroplasty: adjacent fractures occur significantly sooner. , 2006, AJNR. American journal of neuroradiology.

[34]  R. Wasnich Vertebral fracture epidemiology. , 1996, Bone.

[35]  Young Woo Choi,et al.  Risk factors of developing new symptomatic vertebral compression fractures after percutaneous vertebroplasty in osteoporotic patients , 2006, European Spine Journal.

[36]  Nico Verdonschot,et al.  The Influence of Endplate-to-Endplate Cement Augmentation on Vertebral Strength and Stiffness in Vertebroplasty , 2007, Spine.