Heuristic optimization of a continuous flow point-of-use UV-LED disinfection reactor using computational fluid dynamics.

Alternative disinfection sources such as ultraviolet light (UV) are being pursued to inactivate pathogenic microorganisms such as Cryptosporidium and Giardia, while simultaneously reducing the risk of exposure to carcinogenic disinfection by-products (DBPs) in drinking water. UV-LEDs offer a UV disinfecting source that do not contain mercury, have the potential for long lifetimes, are robust, and have a high degree of design flexibility. However, the increased flexibility in design options will add a substantial level of complexity when developing a UV-LED reactor, particularly with regards to reactor shape, size, spatial orientation of light, and germicidal emission wavelength. Anticipating that LEDs are the future of UV disinfection, new methods are needed for designing such reactors. In this research study, the evaluation of a new design paradigm using a point-of-use UV-LED disinfection reactor has been performed. ModeFrontier, a numerical optimization platform, was coupled with COMSOL Multi-physics, a computational fluid dynamics (CFD) software package, to generate an optimized UV-LED continuous flow reactor. Three optimality conditions were considered: 1) single objective analysis minimizing input supply power while achieving at least (2.0) log10 inactivation of Escherichia coli ATCC 11229; and 2) two multi-objective analyses (one of which maximized the log10 inactivation of E. coli ATCC 11229 and minimized the supply power). All tests were completed at a flow rate of 109 mL/min and 92% UVT (measured at 254 nm). The numerical solution for the first objective was validated experimentally using biodosimetry. The optimal design predictions displayed good agreement with the experimental data and contained several non-intuitive features, particularly with the UV-LED spatial arrangement, where the lights were unevenly populated throughout the reactor. The optimal designs may not have been developed from experienced designers due to the increased degrees of freedom offered by using UV-LEDs. The results of this study revealed that the coupled optimization routine with CFD was effective at significantly decreasing the engineer's design decision space and finding a potentially near-optimal UV-LED reactor solution.

[1]  Karl Linden,et al.  Demonstration and evaluation of germicidal UV-LEDs for point-of-use water disinfection. , 2010, Journal of water and health.

[2]  Joel Ducoste,et al.  Microbial UV fluence-response assessment using a novel UV-LED collimated beam system. , 2011, Water research.

[3]  M Jekel,et al.  Application of GaN-based ultraviolet-C light emitting diodes--UV LEDs--for water disinfection. , 2011, Water research.

[4]  Shicheng Zhang,et al.  CFD modeling of a UV-LED photocatalytic odor abatement process in a continuous reactor. , 2012, Journal of hazardous materials.

[5]  R. S. Engelbrecht,et al.  Kinetic modeling of U.V. disinfection of water , 1983 .

[6]  Jiangyong Hu,et al.  Indicators for photoreactivation and dark repair studies following ultraviolet disinfection , 2008, Journal of Industrial Microbiology & Biotechnology.

[7]  C. Haas,et al.  Continuous Flow Residence Time Distribution Function Characterization , 1997 .

[8]  F. Durst,et al.  The Development Lengths of Laminar Pipe and Channel Flows , 2005 .

[9]  Michael S. Shur,et al.  III-nitride based deep ultraviolet light sources , 2008, SPIE OPTO.

[10]  Akira Takahashi,et al.  New water disinfection system using UVA light‐emitting diodes , 2007, Journal of applied microbiology.

[11]  R. Simons,et al.  Optical fluence modelling for ultraviolet light emitting diode-based water treatment systems. , 2014, Water research.

[12]  S. Takizawa,et al.  Application of UV light emitting diodes to batch and flow-through water disinfection systems , 2013 .

[13]  M. Coulter Minamata Convention on Mercury , 2016, International Legal Materials.

[14]  Mika Sillanpää,et al.  Ultraviolet light-emitting diodes in water disinfection , 2009, Environmental science and pollution research international.

[15]  R. Gaska,et al.  UV LEDs for Disinfection , 2022 .

[16]  Joel J. Ducoste,et al.  Assessing the impact of upstream hydraulics on the dose distribution of ultraviolet reactors using fluorescence microspheres and computational fluid dynamics. , 2009 .

[17]  Karl G. Linden,et al.  Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments , 2003 .

[18]  Joel J. Ducoste,et al.  Alternative Approaches to Modeling Fluence Distribution and Microbial Inactivation in Ultraviolet Reactors: Lagrangian versus Eulerian , 2005 .

[19]  B. F. Kalisvaart Re-use of wastewater: preventing the recovery of pathogens by using medium-pressure UV lamp technology. , 2004, Water science and technology : a journal of the International Association on Water Pollution Research.

[20]  Leo J. Schowalter,et al.  UV Light Emitting Diodes - Their Applications and Benefits , 2007 .

[21]  K. Linden,et al.  Comparative Inactivation of Bacillus Subtilis Spores and MS-2 Coliphage in a UV Reactor: Implications for Validation , 2006 .

[22]  Richard M Jenny,et al.  Modeling a continuous flow ultraviolet Light Emitting Diode reactor using computational fluid dynamics , 2014 .

[23]  B. Coulomb,et al.  Multivariate optimization of fecal bioindicator inactivation by coupling UV-A and UV-C LEDs , 2012 .

[24]  D. Giles,et al.  Finite element analysis of particle and liquid flow through an ultraviolet reactor , 1998 .

[25]  Joel J. Ducoste,et al.  Evaluation of alternative fluence rate distribution models , 2004 .

[26]  K. Linden,et al.  Efficiency of pyrimidine dimer formation in Escherichia coli across UV wavelengths , 2007, Journal of applied microbiology.

[27]  Wim S. J. Uijttewaal,et al.  Evaluation of experimental techniques to validate numerical computations of the hydraulics inside a UV bench-scale reactor , 2010 .

[28]  Jeyong Yoon,et al.  Mechanisms of Escherichia coli inactivation by several disinfectants. , 2010, Water research.