Low coherence interferometry modelling using combined broadband Gaussian light sources

Using a Low Coherence Interferometry (LCI) model, a comparison of broadband single-Gaussian and multi-Gaussian light sources has been undertaken. For single-Gaussian sources, the axial resolution improved with source bandwidth, confirming the coherence length relation that resolution for single Gaussian sources improves with increasing spectral bandwidth. However, narrow bandwidth light sources resulted in interferograms with overlapping strata peaks and the loss of individual strata information. For multiple-Gaussian sources with the same bandwidth, spectral side lobes increased, reducing A-scan reliability to show accurate layer information without eliminating the side lobes. The simulations show the conditions needed for resolution of strata information for broadband light sources using both single and multiple Gaussian models. The potential to use the model to study LCI and OCT light sources, optical delays and sample structures can better characterise these LCI and OCT elements. Forecasting misinformation in the interferogram, may allow preliminary corrections. With improvements to the LCI-OCT model, more applications are envisaged.

[1]  H.J.C.M. Sterenborg,et al.  Skin optics , 1989, IEEE Transactions on Biomedical Engineering.

[2]  V. R. Shidlovski,et al.  Novel superluminescent diodes and SLD-based light sources for optical coherence tomography , 2007, European Conference on Biomedical Optics.

[3]  A. Fiore,et al.  Quantum dot superluminescent diodes emitting at 1.3 /spl mu/m , 2005, IEEE Photonics Technology Letters.

[4]  V. R. Shidlovski,et al.  Superluminescent Diode Light Sources for OCT , 2008 .

[5]  Steven Hinckley,et al.  Extrinsic Evolution of the Stacked Gradient Poly-Homojunction Photodiode Genre , 2011 .

[6]  Graham Wild,et al.  Simulation of optical delay lines for Optical Coherence Tomography , 2011, 2011 International Quantum Electronics Conference (IQEC) and Conference on Lasers and Electro-Optics (CLEO) Pacific Rim incorporating the Australasian Conference on Optics, Lasers and Spectroscopy and the Australian Conference on Optical Fibre Technology.

[7]  N. Nishizawa,et al.  Ultrahigh resolution optical coherence tomography , 2012, 2012 17th Opto-Electronics and Communications Conference.

[8]  Michael W. Jenkins,et al.  A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography. , 2008, Optics communications.

[9]  Hyun-Woo Jeong,et al.  High-speed spectral domain polarization- sensitive optical coherence tomography using a single camera and an optical switch at 1.3 microm. , 2010, Journal of biomedical optics.

[10]  D. Sampson,et al.  Semiconductor line source for low-coherence interferometry. , 2001, Applied optics.

[11]  M. Brezinski Optical Coherence Tomography: Principles and Applications , 2006 .

[12]  Harald Sattmann,et al.  Resolution-improved dual-beam and standard optical coherence tomography: a comparison , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[13]  G. Wild,et al.  A micro-photonic stationary Optical Delay Line for fibre optic time domain OCT , 2008, OECC/ACOFT 2008 - Joint Conference of the Opto-Electronics and Communications Conference and the Australian Conference on Optical Fibre Technology.

[14]  Martina Meinke,et al.  Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2,000 nm. , 2009, Journal of biomedical optics.